Installation manual
Page 33 
Rear Panel Connections 
•  The auxiliary alarm contact is capable of switching up to 24 V DC at up to 1 A 
(inductive load). The contacts are not connected to any internal voltages. 
•  The power supply input is isolated from the case and antenna. It must remain 
within the range 10.8 – 31.2 V DC (12/24 V DC nominal) at all times. 
Connecting a Printer 
The recommended external printer option is the Seiko DPU-414; the default printer 
parameters are set correctly for this model. The printer should be connected to the 
NMEA port of the NAV-7 (the 9-way D-type socket at the rear): 
DPU-414 pin 3 (RxD) to NAV-7 pin 7 (TxA) 
DPU-414 pin 5 (Gnd) to NAV-7 pin 2 (TxB) 
TNC RF connector
1
/
8
” Spade terminal – ground pin
9-way D-type – NMEA 0183 & printer port
USB connector –
 not currently used 
15-way D-type – power and IBS port and alarm relay