User manual
Page 37 
Connection 
1 metre cable with screw terminal block 
Expanded system connection with ICS NAV6hub 
Environmental 
Inside/outside mounting 
Waterproof to IEC945 (exposed category) 
IEC945 (EMC) 
CE marked. 
Power requirements 
Voltage range 10.8 V to 15.6 V 
Consumption (Typical) 
Backlight full 310 mA (3.8 W at 12 V) 
Backlight off 165 mA (2.0 W at 12 V) 
Sleep mode 115 mA (1.4 W at 12 V) 
NMEA Data input (NAV6plus/Aplus/repeater ) 
NMEA input port, meets the electrical requirements of NMEA 0183 
NMEA GPS/Instrument system interface supports NMEA 0183 V2.0 or higher 
Input/output Interface Specification 
Preferred NMEA sentences: RMC, HDT, HDG, VBW, MWV, VLW, DPT, 
ROT, VDR, RMB and BWC 
Minimum recommended NMEA sentences: RMC and RMB 
Data output (NAV6plus/Aplus/repeater only) 
RS232 serial data, supports the printing of vessel ‘Log reports‘ and NAVTEX 
message text to NAV6printer or a computer system running compatible 
software 
NMEA logging Interval (NAV6plus/Aplus/repeater only) 
off,15, 20, 30 mins, 1, 2, 3, 4, 5, 6,12 hours. 256 log entries 
NMEA Repeater Display (NAV6plus/Aplus/repeater only) 
9 User selectable NMEA instrument and navigation screens 
NAV6Aplus specifications 
Power Requirements 
70mA at 12V (supplied by NAV6 display or NAV6hub) 
Antenna input 
1.  50ohm, range 490 - 518 kHz 12 Vdc to feed to power an active antenna 
is selectable at installation 
2.  Hi impedance wide range, supports connection of longer than 
2 m of insulated wire or whip antenna 