User guide

Page 36
Connection
1 metre cable with screw terminal block
Expanded system connection with ICS NAV6hub
Environmental
Inside/outside mounting
Waterproof to IEC945 (exposed category)
IEC945 (EMC)
CE marked.
Power requirements
Voltage range 10.8 V to 15.6 V
Consumption (Typical)
Backlight full 310 mA (3.8 W at 12 V)
Backlight off 165 mA (2.0 W at 12 V)
Sleep mode 115 mA (1.4 W at 12 V)
NMEA Data input (ICS NAV6plus/Aplus/repeater )
NMEA input port, meets the electrical requirements of NMEA 0183
NMEA GPS/Instrument system interface supports NMEA 0183 V2.0 or
higher
Input/output Interface Specification
Preferred NMEA sentences: RMC, HDT, HDG, VBW, MWV, VLW, DPT,
ROT, VDR, RMB and BWC
Minimum recommended NMEA sentences: RMC and RMB
Data output (ICS NAV6plus/Aplus/repeater only)
RS232 serial data, supports the printing of vessel ‘Log reports‘ and
NAVTEX message text to ICS NAV6printer or a computer system
running compatible software
NMEA logging Interval (ICS NAV6plus/Aplus/repeater only)
off,15, 20, 30 mins, 1, 2, 3, 4, 5, 6,12 hours. 256 log entries
NMEA Repeater Display (ICS NAV6plus/Aplus/repeater only)
9 User selectable NMEA instrument and navigation screens
ICS NAV6Aplus specifications
Power Requirements
70mA at 12V (supplied by ICS NAV6 display or ICS NAV6hub)
Antenna input
1. 50ohm, range 490 - 518 kHz 12 Vdc to feed to power an active
antenna is selectable at installation
2. Hi impedance wide range, supports connection of longer than
2 m of insulated wire or whip antenna
Physical Dimensions