MCK - 2005 Ceiling Cassette Split Systems Models: MCK MCK MCK MCK MCK 020A/AR 025A/AR 030A/AR 040A/AR 050A/AR MCK 015B/BR MCK 020B/BR MCK 025B/BR MCK/M5CK 010C/CR MCK/M5CK 015C/CR MCK 020C/CR
Contents Special Feature ............................................................................................................. 1 Specifications ................................................................................................................ 2 Noise Level ................................................................................................................... 20 Operating Range ..................................................................................................
Special F ea tur e Fea eatur ture eature Ultra Slim New Stylish Design Profile This unit is contemporary in design and match even the most up to date interior decor. The slim, (only 20mm for C-series, 22 mm for B-series and only 28 mm for A-series) and round profile front panel of this unit adds a touch of elegance to every decor. Turbo Mixed Flow Fan Innovative design of highly efficient turbo fan produces an even air circulation in all direction.
Ceiling Cassette A Series (Cooling Only - R407C) MODEL INDOOR UNIT OUTDOOR UNIT FIN COIL COMPRESSOR INDOOR UNIT TUBE FAN NOMINAL COOLING W CAPACITY Btu/h W NOMINAL TOTAL POWER - 1∅ [ 3∅ ] A NOMINAL TOTAL CURRENT - 1∅ [ 3∅ ] POWER SOURCE V/Ph/Hz REFRIGERANT / CONTROL AIR FLOW cfm / L/s FAN MOTOR RATED INPUT POWER W RATED RUNNING CURRENT A MATERIAL DIAMETER mm/in THICKNESS mm/in MATERIAL THICKNESS mm/in ROW FIN PER INCH 2 2 FACE AREA m /ft DIMENSION HEIGHT mm/in ( ) - WITH PANEL WIDTH mm/in DEPTH mm/i
Ceiling Cassette A Series (Cooling Only - R407C) MODEL INDOOR UNIT OUTDOOR UNIT MCK 050A M4LC 040C M4LC 050C 11134 14650 38000 50000 3861 [ 4165 ] [ 4803 ] 18.0 [ 6.9 ] [ 8.9 ] 220 - 240 / 1 / 50 R407C / CAPILLARY TUBE (INDOOR) 990 / 467 1080 / 510 6 POLES x 85W 6 POLES x 120W 192 242 0.80 1.03 S.I.G.C 7.00 / 0.28 0.28 / 0.011 ALUMINIUM (HYDROPHILIC) 0.11 / 0.0043 3 3 20 20 0.469 / 5.022 0.469 / 5.022 335 (363) / 13.2 (14.3) 820 (930) / 32.2 (36.6) 820 (930) / 32.2 (36.6) 38 + 4 / 83.8 + 8.8 40 + 4 / 88.
Ceiling Cassette A Series (Heat Pump - R407C) MODEL INDOOR UNIT OUTDOOR UNIT COIL FIN COMPRESSOR INDOOR UNIT TUBE FAN NOMINAL COOLING W CAPACITY Btu/h NOMINAL HEATING W CAPACITY Btu/h W NOMINAL TOTAL POWER (COOLING) - 1∅ [ 3∅ ] W NOMINAL TOTAL POWER (HEATING) - 1∅ [ 3∅ ] A NOMINAL TOTAL CURRENT (COOLING) - 1∅ [ 3∅ ] A NOMINAL TOTAL CURRENT (HEATING) - 1∅ [ 3∅ ] POWER SOURCE V/Ph/Hz REFRIGERANT / CONTROL AIR FLOW cfm / L/s FAN MOTOR RATED INPUT POWER W RATED RUNNING CURRENT A MATERIAL DIAMETER mm/in
Ceiling Cassette A Series (Heat Pump - R407C) MODEL INDOOR UNIT OUTDOOR UNIT FIN COIL COMPRESSOR INDOOR UNIT TUBE FAN NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY NOMINAL TOTAL POWER (COOLING) - 1∅ [ 3∅ ] NOMINAL TOTAL POWER (HEATING) - 1∅ [ 3∅ ] NOMINAL TOTAL CURRENT (COOLING) - 1∅ [ 3∅ ] NOMINAL TOTAL CURRENT (HEATING) - 1∅ [ 3∅ ] POWER SOURCE REFRIGERANT / CONTROL AIR FLOW FAN MOTOR RATED INPUT POWER RATED RUNNING CURRENT MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AR
Ceiling Cassette B Series (Cooling Only - R407C) MODEL INDOOR UNIT OUTDOOR UNIT COIL FIN TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR INDOOR UNIT TUBE FAN NOMINAL COOLING W CAPACITY Btu/h NOMINAL TOTAL POWER - 1∅ [ 3∅ ] W NOMINAL TOTAL CURRENT - 1∅ [ 3∅ ] A POWER SOURCE V/Ph/Hz REFRIGERANT / CONTROL AIR FLOW cfm / L/s FAN MOTOR RATED INPUT POWER W RATED RUNNING CURRENT A MATERIAL DIAMETER mm/in THICKNESS mm/in MATERIAL THICKNESS mm/in ROW FIN PER INCH m2/ft2 FACE AREA DIMENSION HEIGHT mm/in W
Ceiling Cassette B Series (Heat Pump - R407C) MODEL INDOOR UNIT OUTDOOR UNIT COIL FIN TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR INDOOR UNIT TUBE FAN NOMINAL COOLING W CAPACITY Btu/h NOMINAL HEATING W CAPACITY Btu/h NOMINAL TOTAL POWER (COOLING) - 1∅ [ 3∅ ] W NOMINAL TOTAL POWER (HEATING) - 1∅ [ 3∅ ] W A NOMINAL TOTAL CURRENT (COOLING) - 1∅ [ 3∅ ] NOMINAL TOTAL CURRENT (COOLING) - 1∅ [ 3∅ ] A V/Ph/Hz POWER SOURCE REFRIGERANT / CONTROL AIR FLOW cfm / L/s FAN MOTOR RATED INPUT POWER W RATED R
Ceiling Cassette C Series (Cooling Only - R407C) MODEL INDOOR UNIT OUTDOOR UNIT COIL FIN MCK 015C MCK 020C M4LC 015B M4LC 020B 3515 5272 12000 18000 1445 2347 [ 1997 ] 6.3 10.8 [ 3.9 ] 220 - 240 / 1 / 50 R407C / CAPILLARY TUBE (OUTDOOR) 410 / 194 410 / 194 450 / 212 6 POLES x 16W 6 POLES x 18W 6 POLES x 22W 56 60 68 0.24 0.27 0.30 S.I.G.C 7.00 / 0.28 0.28 / 0.011 ALUMINIUM (HYDROPHILLIC) 0.11 / 0.0043 2 1 20 0.318 / 3.42 250 (295) / 9.8 (11.6) 570 (640) / 22.4 (25.2) 570 (640) / 22.4 (25.
Ceiling Cassette C Series (Heat Pump - R407C) MODEL INDOOR UNIT OUTDOOR UNIT COIL FIN MCK 015CR MCK 020CR M4LC 015BR M4LC 020BR 3368 5272 11500 18000 3222 5418 11000 18500 1442 2324 1161 2189 6.3 10.8 5.3 9.9 230 / 1 / 50 R407C / CAPILLARY TUBE (OUTDOOR) 410 / 194 410 / 194 450 / 212 6 POLES x 16W 6 POLES x 18W 6 POLES x 22W 56 60 68 0.24 0.27 0.3 S.I.G.C 7.00 / 0.28 0.28 / 0.011 ALUMINIUM (HYDROPHILLIC) 0.11 / 0.0043 2 1 20 16 0.318 / 3.42 250 (295) / 9.8 (11.6) 570 (640) / 22.4 (25.2) 570 (640) / 22.
Ceiling Cassette C Series (Cooling Only - R410A) INDOOR UNIT OUTDOOR UNIT MODEL COIL FIN TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR INDOOR UNIT TUBE FAN NOMINAL COOLING W CAPACITY Btu/h NOMINAL TOTAL POWER W NOMINAL TOTAL CURRENT A POWER SOURCE V/Ph/Hz REFRIGERANT / CONTROL AIR FLOW cfm / L/s FAN MOTOR RATED INPUT POWER (W) W RATED RUNNING CURRENT (A) A MATERIAL DIAMETER mm/in THICKNESS mm/in MATERIAL THICKNESS mm/in ROW FIN PER INCH FACE AREA m2/ft2 DIMENSION HEIGHT mm/in ( ) - WITH PANEL
Ceiling Cassette C Series (Heat Pump - R410A) INDOOR UNIT OUTDOOR UNIT MODEL COIL FIN TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR INDOOR UNIT TUBE FAN NOMINAL COOLING W CAPACITY Btu/h NOMINAL HEATING W CAPACITY Btu/h NOMINAL TOTAL POWER (COOLING) W NOMINAL TOTAL POWER (HEATING) W NOMINAL TOTAL CURRENT (COOLING) A NOMINAL TOTAL CURRENT (HEATING) A POWER SOURCE V/Ph/Hz REFRIGERANT / CONTROL AIR FLOW cfm / L/s FAN MOTOR RATED INPUT POWER W RATED RUNNING CURRENT A MATERIAL DIAMETER mm/in THICKNE
Noise Level MCK-A/AR Model Speed MCK 020A/AR High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low MCK 025A/AR MCK 030A/AR MCK 040A/AR MCK 050A/AR 1/1 Octave A-weighted Sound Pressure (dBA), ref 20µPa 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz 46 45 40 38 32 21 14 44 43 37 33 28 18 12 43 42 35 31 26 17 11 48 46 43 39 33 27 19 45 43 40 35 29 21 15 43 42 38 32 27 19 14 50 48 47 43 37 35 28 48 45 43 38 32 31 27 46 43 41 35 30 30 26 50 49 49 46 39 38 31 48 47 47 43 36 34 25 46 45 46
Model MCK 020A/AR MCK 025A/AR MCK 015B/BR MCK 020B/BR MCK 025B/BR MCK / M5CK 010C/CR MCK / M5CK 015C/CR MCK 020C/CR MCK 030A/AR MCK 040A/AR MCK 050A/AR Measuring location Standard : JIS C 9612 Standard : JIS B 8615 21
NC Curves MCK 020A/AR NC Curves 70 Sound pressure level (dB, ref 20µPa) 60 50 NC-50 NC-45 40 High fan NC-40 Medium fan NC-35 30 NC-30 Low fan NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) Measured in anechoic room at 1.
MCK 030A/AR NC Curves 70 Sound pressure level (dB, ref 20µPa) 60 50 NC-50 High fan NC-45 Medium fan NC-40 40 NC-35 Low fan 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) Measured in anechoic room at 1.
MCK 050A/AR NC Curves Sound pressure level (dB, ref 20µPa) 70 60 50 NC-50 High fan Medium fan Low fan NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 10 0 125 250 500 1000 2000 Octave-band frequency (Hz) Measured in anechoic room at 1.
25
26
MCK 010C/CR NC Curves MCK 015C/CR NC Curves 27
MCK 020C/CR NC Curves 28
Oper a ang e Opera Rang ange ating ting R Range Ensure the operating temperature is in allowable range. Cooling only Cooling Outdoor temp. (°CDB) 54 ! HIGH AMBIENT UNIT 46 Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. 35 STD 19 LOW AMBIENT KIT -5 24 15 Indoor temp. (°CWB) Heat pump Heating Cooling 54 Outdoor temp. (°CDB) Outdoor temp.
Refrig er ant Cir cuit efriger erant Circuit efrigerant Model : MCK 015B – MLC 015C MCK/M5CK 010/015C - MLC/M5LC 010/015C MCK 015B – M4LC 015B MCK 010/ 015C - M4LC 010/ 015B MCK 020A - MLC/M4LC 020B MCK 020C – MLC/M4LC 020B MCK 020B – MLC/M4LC 020B Model : MCK 025A - MLC/ M4LC 025B MCK 025B - MLC/M4LC 025B 30
Model : MCK 030A – MLC 030B Model : MCK 030A – MLC/M4LC 030C MCK 040A – MLC/M4LC 035C MCK 040A – MLC/M4LC 040C MCK 050A – MLC/M4LC 050C 31
Model : MCK/M5CK 010CR - MLC/M5LC 010CR MCK 010CR - M4LC 010BR Model : MCK 015BR - MLC 015CR MCK/M5CK 015CR - MLC/M5LC 015CR 32
Model : MCK 015BR - M4LC 015BR MCK 015CR - M4LC 015BR Model : MCK 020AR – MLC/M4LC 020BR MCK 020BR – MLC/M4LC 020BR 33 MCK 020CR – MLC/M4LC 020BR
Model : MCK 025AR – MLC/M4LC 025BR MCK 030AR – MLC 030BR Model : MCK 030AR – MLC/M4LC 030CR MCK 040AR – MLC/M4LC 035CR MCK 040AR – MLC/M4LC 040CR MCK 050AR – MLC/M4LC 050CR 34 MCK 025BR – MLC/M4LC 025BR
or mance T able erfor ormance Perf erformance Table Interpolation and Extrapolation method can be used to get the total capacity, TC and sensible capacity, SC at those temperatures which are not stated out in the table. Example: Model: MCK 0 20A / MLC 0 20B Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB Solution: Overall Based on the Performance table on Pg.(39), 1. Refer to the Indoor DB column, - 23°C is located between 20°C and 24°C (Thus, Interpolation need to be applied) 2.
Details: 1st Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 24°C DB, 15°C WB Outdoor Condition: 35°C DB Indoor DB ˚C Outdoor DB, ˚C 35 TC (kW) SC (kW) Indoor WB ˚C 15 16 17 24 x1 5.597 5.761 y1 4.008 3.873 Total capacity, TC => = 5.433kW (Same as Total capacity at 20°C Indoor DB / 15°C Indoor WB & 35°C Outdoor WB)* Sensible capacity, SC Extrapolation Method: 17°C - 15°C 3.873kW - y1 => = 17°C - 15°C 3.873kW - 4.008kW =>y1 = 4.
2nd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 35°C DB Indoor DB ˚C Indoor WB ˚C 20 23 24 15 15 15 Outdoor DB, ˚C 35 TC (kW) SC (kW) 5.433 x3 5.433 2.72 y3 4.143 Total capacity, TC => = 5.433kW (Same as Total capacity at 20°C Indoor DB / 15°C Indoor WB & 35°C Outdoor WB)* Sensible capacity, SC Interpolation Method: 24°C - 20°C 4.143kW - 2.72kW => = 24°C - 23°C 4.143kW - y3 => y3 = 3.
3rd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB Indoor DB ˚C Indoor WB ˚C TC (kW) 23 15 5.433 35 Outdoor DB, ˚C 37 SC (kW) TC (kW) SC (kW) 3.787 Total capacity, TC Interpolation Method: 40°C - 35°C => 4.918kW - 5.433kW = 40°C - 37°C 4.918kW - x => x = 5.227kW Sensible capacity, SC Interpolation Method: 40°C - 35°C => 3.302kW - 3.787kW = 40°C - 37°C 3.302kW - y =>y = 3.593kW 38 x y 40 TC (kW) SC (kW) 4.
A Series (Cooling Only – R22) Model : MCK 020A / MLC 020B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 6.523 3.826 6.160 3.457 5.797 3.088 5.433 2.720 4.918 2.235 4.561 1.900 4.388 1.738 4.268 1.625 16 6.582 3.602 6.254 3.263 5.926 2.923 5.597 2.584 5.066 2.113 4.699 1.787 4.521 1.629 4.397 1.519 16 6.582 5.025 6.254 4.
Model : MCK 030A / MLC 030B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 9.157 5.284 8.521 4.713 7.885 4.142 7.248 3.571 6.901 3.244 6.538 2.903 16 9.229 4.789 8.619 4.304 8.009 3.819 7.400 3.333 7.045 3.018 6.674 2.688 16 9.229 6.730 8.619 6.244 8.009 5.759 7.400 5.273 7.045 4.958 6.674 4.628 17 9.300 6.235 8.717 5.835 8.134 5.435 7.551 5.036 7.189 4.732 6.
R22 Models A Series (Cooling Only) Model : MCK 040A / MLC 035C Outdoor DB°C ID DB°C ID WB°C 20 25 35 30 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 11.244 7.053 10.539 6.380 9.833 5.708 9.127 5.035 8.358 4.331 7.587 3.624 16 11.372 6.394 10.703 5.788 10.034 5.182 9.365 4.577 8.576 3.911 7.784 3.243 16 11.372 8.379 10.703 7.774 10.034 7.168 9.365 6.562 8.576 5.897 7.784 5.228 17 11.500 7.720 10.868 7.181 10.
Model : MCK 050A / MLC 050C Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 14.910 9.531 14.049 8.876 13.188 8.222 12.327 7.567 11.615 6.918 10.962 6.323 10.580 5.976 10.243 5.668 16 15.714 8.772 14.739 8.192 13.765 7.612 12.790 7.031 12.051 6.413 11.373 5.847 10.978 5.516 10.627 5.223 16 15.714 10.958 14.739 10.378 13.765 9.798 12.790 9.
R22 Models A Series (Heatpump) Model : MCK 020AR / MLC 020BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 6.706 4.180 6.272 3.690 5.837 3.200 5.403 2.710 4.890 2.233 4.535 1.903 4.364 1.744 4.244 1.632 16 6.774 4.057 6.361 3.538 5.948 3.019 5.535 2.499 5.010 2.042 4.646 1.726 4.471 1.573 4.348 1.467 16 6.774 5.
R22 Models A Series (Heatpump) Model : MCK 025AR / MLC 025BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 54 50 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 7.901 4.239 7.396 3.832 6.891 3.424 6.386 3.016 6.190 2.832 5.875 2.538 5.724 2.398 5.620 2.301 16 8.315 4.003 7.744 3.617 7.172 3.230 6.600 2.843 6.397 2.665 6.072 2.380 5.916 2.243 5.808 2.149 16 8.315 5.
R22 Models A Series (Heatpump) Model : MCK 030AR / MLC 030BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 9.097 5.085 8.425 4.491 7.752 3.897 7.080 3.302 6.740 2.980 6.386 2.644 16 9.152 4.597 8.502 4.097 7.853 3.596 7.203 3.095 6.857 2.783 6.497 2.457 16 9.152 6.636 8.502 6.135 7.853 5.635 7.203 5.134 6.857 4.822 6.497 4.496 17 9.207 6.148 8.580 5.741 7.
R22 Models A Series (Heatpump) Model : MCK 030AR / MLC 030CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 25 20 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 9.384 5.273 8.824 4.800 8.264 4.327 7.703 3.854 7.334 3.509 6.948 3.148 6.648 2.868 6.314 2.555 16 9.688 4.882 9.109 4.470 8.530 4.058 7.951 3.645 7.569 3.310 7.172 2.960 6.862 2.688 6.516 2.384 16 9.688 6.
R22 Models A Series (Heatpump) Model : MCK 040AR / MLC 035CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 11.168 6.950 10.477 6.334 9.786 5.718 9.095 5.102 8.404 4.486 7.575 3.746 16 11.314 6.195 10.656 5.681 9.998 5.166 9.340 4.651 8.683 4.137 7.894 3.519 16 11.314 8.122 10.656 7.608 9.998 7.093 9.340 6.579 8.683 6.064 7.894 5.446 17 11.459 7.367 10.834 6.
R22 Models A Series (Heatpump) Model : MCK 040AR / MLC 040CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 12.397 7.717 11.661 7.112 10.925 6.506 10.189 5.901 9.330 5.098 8.469 4.294 8.147 3.993 8.028 3.882 16 12.916 7.273 12.123 6.729 11.330 6.185 10.538 5.641 9.650 4.861 8.759 4.078 8.426 3.786 8.303 3.677 16 12.916 9.434 12.
R22 Models A Series (Heatpump) Model : MCK 050AR / MLC 050CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 14.910 9.531 14.049 8.876 13.188 8.222 12.327 7.567 11.615 6.918 10.962 6.323 10.580 5.976 10.243 5.668 16 15.714 8.772 14.739 8.192 13.765 7.612 12.790 7.031 12.051 6.413 11.373 5.847 10.978 5.516 10.627 5.223 16 15.714 10.
R407C Models A Series (Cooling Only) Model : MCK 020A / M4LC 020B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 5.684 3.027 5.368 2.706 5.051 2.385 4.735 2.063 4.418 1.742 4.039 1.356 16 5.736 2.832 5.450 2.537 5.164 2.241 4.878 1.945 4.592 1.650 4.248 1.295 16 5.736 4.256 5.450 3.960 5.164 3.665 4.878 3.369 4.592 3.074 4.248 2.719 17 5.788 4.060 5.532 3.
R407C Models A Series (Cooling Only) Model : MCK 030A / M4LC 030C Outdoor DB°C ID DB°C 20 24 28 30 ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 9.852 5.733 9.188 5.144 8.525 4.556 7.861 3.967 7.197 3.379 6.401 2.672 16 10.156 5.400 9.462 4.849 8.767 4.298 8.073 3.747 7.378 3.196 6.545 2.535 16 10.156 7.442 9.462 6.890 8.767 6.339 8.073 5.788 7.378 5.237 6.545 4.576 17 10.
R407C Models A Series (Cooling Only) Model : MCK 040A / M4LC 040C Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 11.226 7.023 10.647 6.555 10.068 6.086 9.489 5.617 8.910 5.148 8.216 4.586 16 11.729 6.559 11.107 6.147 10.485 5.736 9.864 5.325 9.242 4.913 8.496 4.420 16 11.729 8.432 11.107 8.021 10.485 7.610 9.864 7.198 9.242 6.787 8.496 6.293 17 12.231 7.
R407C Models A Series (Heatpump) Model : MCK 020AR / M4LC 020BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 6.036 3.531 5.645 3.090 5.254 2.649 4.863 2.208 4.471 1.766 4.002 1.237 16 6.097 3.420 5.725 2.952 5.353 2.485 4.982 2.018 4.610 1.551 4.164 0.990 16 6.097 4.802 5.725 4.335 5.353 3.867 4.982 3.400 4.610 2.933 4.164 2.372 17 6.158 4.
R407C Models A Series (Heatpump) Model : MCK 025AR / M4LC 025BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 6.479 2.946 6.065 2.612 5.651 2.277 5.237 1.943 4.823 1.608 4.326 1.207 16 6.819 2.752 6.350 2.435 5.881 2.118 5.412 1.801 4.943 1.484 4.381 1.104 16 6.819 4.511 6.350 4.194 5.881 3.877 5.412 3.560 4.943 3.243 4.381 2.862 17 7.159 4.
R407C Models A Series (Heatpump) Model : MCK 030AR / M4LC 030CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 9.072 4.986 8.530 4.529 7.988 4.071 7.446 3.614 6.905 3.156 6.254 2.608 16 9.365 4.608 8.805 4.209 8.245 3.811 7.686 3.412 7.126 3.013 6.454 2.535 16 9.365 6.606 8.805 6.208 8.245 5.809 7.686 5.410 7.126 5.012 6.454 4.533 17 9.658 6.
R407C Models A Series (Heatpump) Model : MCK 040AR / M4LC 035CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 11.168 6.950 10.477 6.334 9.786 5.718 9.095 5.102 8.404 4.486 7.575 3.746 16 11.314 6.195 10.656 5.681 9.998 5.166 9.340 4.651 8.683 4.137 7.894 3.519 16 11.314 8.122 10.656 7.608 9.998 7.093 9.340 6.579 8.683 6.064 7.894 5.446 17 11.
R407C Models A Series (Heatpump) Model : MCK 040AR / M4LC 040CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 12.087 7.434 11.369 6.844 10.652 6.253 9.934 5.663 9.217 5.072 8.356 4.364 16 12.593 7.000 11.820 6.470 11.047 5.940 10.274 5.410 9.501 4.879 8.574 4.243 16 12.593 9.161 11.820 8.631 11.047 8.101 10.274 7.570 9.501 7.040 8.574 6.
R407C Models A Series (Heatpump) Model : MCK 050AR / M4LC 050CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 14.910 9.531 14.049 16 16 8.876 13.188 8.222 12.327 7.567 11.466 6.913 10.433 6.127 15.714 8.772 14.739 8.192 13.765 7.612 12.790 7.031 11.816 6.451 10.646 5.755 15.714 10.958 14.739 10.378 13.765 9.798 12.790 9.217 11.816 8.637 10.646 7.
R22 Models B Series (Cooling Only) Model : MCK 015B / MLC 015C Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 4.179 2.552 3.911 2.300 3.642 2.048 3.374 1.795 3.105 1.543 2.783 1.241 16 4.218 2.334 3.965 2.111 3.711 1.888 3.457 1.665 3.203 1.442 2.899 1.175 16 4.218 3.136 3.965 2.913 3.711 2.690 3.457 2.467 3.203 2.244 2.899 1.977 17 4.258 2.917 4.019 2.
R22 Models B Series (Cooling Only) Model : MCK 025B / MLC 025B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 54 50 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 6.787 4.252 6.460 4.007 6.133 3.762 5.805 3.518 5.627 3.354 5.341 3.092 5.203 2.966 5.109 2.880 16 7.334 4.154 6.917 3.890 6.501 3.627 6.085 3.364 5.897 3.205 5.598 2.951 5.454 2.829 5.355 2.745 16 7.334 5.228 6.917 4.
R22 Models B Series (Heatpump) Model : MCK 015BR / MLC 015CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 4.179 2.552 3.911 2.300 3.642 2.048 3.374 1.795 3.105 1.543 2.783 1.241 16 4.218 2.334 3.965 2.111 3.711 1.888 3.457 1.665 3.203 1.442 2.899 1.175 16 4.218 3.136 3.965 2.913 3.711 2.690 3.457 2.467 3.203 2.244 2.899 1.977 17 4.258 2.917 4.019 2.724 3.
R22 Models B Series (Heatpump) Model : MCK 020BR / MLC 020BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 5.659 3.547 5.377 3.310 5.094 3.074 4.811 2.838 4.354 2.422 4.038 2.134 3.886 1.995 3.779 1.898 16 5.775 3.283 5.511 3.081 5.247 2.879 4.983 2.677 4.510 2.277 4.183 2.000 4.025 1.866 3.914 1.772 16 5.775 4.204 5.511 4.
R22 Models B Series (Heatpump) Model : MCK 025BR / MLC 025BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 6.645 4.156 6.313 3.898 5.981 3.640 5.649 3.382 5.475 3.222 5.197 2.967 5.063 2.844 4.971 2.760 16 7.066 3.976 6.677 3.722 6.287 3.469 5.897 3.215 5.716 3.061 5.425 2.813 5.286 2.695 5.190 2.613 16 7.066 5.051 6.677 4.
R407C Models B Series (Cooling Only) Model : MCK 015B / M4LC 015B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 3.833 2.160 3.563 1.931 3.294 1.701 3.025 1.472 2.755 1.242 2.432 0.967 16 3.970 2.048 3.681 1.835 3.392 1.622 3.103 1.409 2.814 1.197 2.468 0.941 16 3.970 2.882 3.681 2.669 3.392 2.457 3.103 2.244 2.814 2.031 2.468 1.776 17 4.107 2.770 3.799 2.
R407C Models B Series (Cooling Only) Model : MCK 025B / M4LC 025B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 6.222 3.747 5.922 3.523 5.622 3.299 5.322 3.075 5.022 2.851 4.662 2.581 16 6.723 3.657 6.341 3.416 5.959 3.175 5.578 2.934 5.196 2.693 4.738 2.403 16 6.723 4.732 6.341 4.491 5.959 4.250 5.578 4.009 5.196 3.768 4.738 3.478 17 7.224 4.642 6.760 4.384 6.297 4.
R407C Models B Series (Heatpump) Model : MCK 015BR / M4LC 015BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 3.705 2.043 3.472 1.846 3.238 1.649 3.004 1.451 2.770 1.254 2.490 1.017 16 3.782 1.880 3.551 1.718 3.319 1.556 3.087 1.394 2.856 1.232 2.578 1.037 16 3.782 2.714 3.551 2.552 3.319 2.390 3.087 2.228 2.856 2.066 2.578 1.872 17 3.859 2.
R407C Models B Series (Heatpump) Model : MCK 020BR / M4LC 020BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 5.361 3.279 5.094 3.055 4.826 2.831 4.558 2.607 4.290 2.383 3.968 2.115 16 5.471 3.029 5.221 2.838 4.971 2.647 4.721 2.455 4.471 2.264 4.171 2.034 16 5.471 3.950 5.221 3.759 4.971 3.568 4.721 3.376 4.471 3.185 4.171 2.955 17 5.581 3.
R407C Models B Series (Heatpump) Model : MCK 025BR / M4LC 025BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 6.356 3.897 6.038 3.650 5.721 3.403 5.404 3.156 5.086 2.909 4.705 2.613 16 6.759 3.725 6.386 3.482 6.014 3.240 5.641 2.997 5.268 2.754 4.821 2.463 16 6.759 4.800 6.386 4.557 6.014 4.315 5.641 4.072 5.268 3.829 4.821 3.538 17 7.162 4.627 6.734 4.
R22 Models C Series (Cooling Only) Model : MCK 010C / MLC 010C Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 3.180 1.885 2.961 1.698 2.741 1.511 2.522 1.324 2.302 1.138 2.039 0.913 16 3.245 1.725 3.024 1.566 2.803 1.407 2.581 1.248 2.360 1.089 2.095 0.899 16 3.245 2.350 3.024 2.191 2.803 2.033 2.581 1.874 2.360 1.715 2.095 1.524 17 3.309 2.190 3.086 2.
R22 Models C Series (Cooling Only) Model : MCK 020C - MLC 020B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 5.676 3.585 5.410 3.356 5.145 3.126 4.879 2.896 4.416 2.473 4.096 2.181 3.941 2.040 3.833 1.941 16 5.830 3.323 5.576 3.125 5.323 2.926 5.069 2.728 4.588 2.321 4.255 2.040 4.094 1.904 3.982 1.809 16 5.830 4.253 5.576 4.055 5.323 3.
R22 Model C Series (Heatpump) Model : MCK 010CR / MLC 010CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 3.180 1.885 2.961 1.698 2.741 1.511 2.522 1.324 2.302 1.138 2.039 0.913 16 3.245 1.725 3.024 1.566 2.803 1.407 2.581 1.248 2.360 1.089 2.095 0.899 16 3.245 2.350 3.024 2.191 2.803 2.033 2.581 1.874 2.360 1.715 2.095 1.524 17 3.309 2.190 3.
R22 Models C Series (Heatpump) Model : MCK 015CR / MLC 015CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 4.276 2.735 3.989 2.448 3.702 2.161 3.415 1.873 3.128 1.586 2.783 1.242 16 4.294 2.539 4.026 2.271 3.757 2.002 3.489 1.734 3.221 1.466 2.899 1.144 16 4.294 3.319 4.026 3.051 3.757 2.783 3.489 2.514 3.221 2.246 2.899 1.924 17 4.311 3.123 4.
R22 Models C Series (Heatpump) Model : MCK 020CR / MLC 020BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 50 54 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 5.232 3.173 4.988 2.956 4.744 2.738 4.500 2.521 4.073 2.128 3.778 1.856 3.635 1.725 3.535 1.633 16 5.378 2.920 5.144 2.737 4.911 2.554 4.677 2.371 4.233 1.992 3.926 1.730 3.777 1.604 3.674 1.515 16 5.378 3.
R407C Models C Series (Cooling Only) Model : MCK 010C / M4LC 010B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 3.104 1.824 2.890 1.633 2.676 1.442 2.462 1.251 2.248 1.060 1.991 0.831 16 3.135 1.679 2.928 1.516 2.722 1.354 2.515 1.191 2.309 1.029 2.061 0.834 16 3.135 2.328 2.928 2.165 2.722 2.003 2.515 1.840 2.309 1.678 2.061 1.483 17 3.165 2.183 2.966 2.
R407C Models C Series (Cooling Only) Model : MCK 020C / M4LC 020B Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 5.239 3.190 4.994 2.978 4.749 2.766 4.504 2.554 4.259 2.342 3.965 2.087 16 5.381 2.947 5.147 2.764 4.913 2.581 4.679 2.398 4.445 2.215 4.164 1.996 16 5.381 3.878 5.147 3.695 4.913 3.512 4.679 3.329 4.445 3.146 4.164 2.926 17 5.524 3.635 5.301 3.481 5.078 3.
R407C Models C Series (Heatpump) Model : MCK 010CR / M4LC 010BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 3.080 1.841 2.867 1.651 2.655 1.461 2.442 1.270 2.229 1.080 1.974 0.851 16 3.142 1.730 2.928 1.558 2.714 1.387 2.500 1.215 2.286 1.043 2.029 0.837 16 3.142 2.356 2.928 2.184 2.714 2.012 2.500 1.841 2.286 1.669 2.029 1.463 17 3.205 2.244 2.989 2.
R407C Models C Series (Heatpump) Model : MCK 015CR / M4LC 015BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 3.756 2.132 3.516 1.912 3.276 1.693 3.036 1.473 2.796 1.254 2.508 0.990 16 3.793 1.954 3.566 1.766 3.339 1.578 3.112 1.390 2.884 1.202 2.612 0.976 16 3.793 2.782 3.566 2.594 3.339 2.406 3.112 2.218 2.884 2.030 2.612 1.804 17 3.831 2.605 3.617 2.
R407C Models C Series (Heatpump) Model : MCK 020CR / M4LC 020BR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 5.232 3.173 4.988 2.956 4.744 2.738 4.500 2.521 4.256 2.304 3.964 2.043 16 5.378 2.920 5.144 2.737 4.911 2.554 4.677 2.371 4.443 2.188 4.162 1.969 16 5.378 3.887 5.144 3.704 4.911 3.521 4.677 3.339 4.443 3.156 4.162 2.936 17 5.524 3.634 5.301 3.
R410A Models C Series (Cooling Only) Model : M5CK 010C / M5LC 010C Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 24 28 30 15 3.339 2.107 3.079 1.847 2.824 1.592 2.568 1.337 2.313 1.082 2.007 0.776 16 3.384 1.955 3.132 1.717 2.882 1.482 2.633 1.247 2.383 1.012 2.084 0.730 16 3.384 2.658 3.132 2.421 2.882 2.186 2.633 1.951 2.383 1.716 2.084 1.434 17 3.428 2.506 3.185 2.
R410A Models C Series (Heatpump) Model : M5CK 010CR / M5LC 010CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 3.339 2.107 3.079 1.847 2.824 1.592 2.568 1.337 2.313 1.082 2.007 0.776 16 3.384 1.955 3.132 1.717 2.882 1.482 2.633 1.247 2.383 1.012 2.084 0.730 16 3.384 2.658 3.132 2.421 2.882 2.186 2.633 1.951 2.383 1.716 2.084 1.434 17 3.428 2.506 3.185 2.
R410A Models C Series (Heatpump) Model : M5CK 015CR / M5LC 015CR Cooling Mode Outdoor DB°C ID DB°C ID WB°C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 4.111 2.643 3.827 2.359 3.558 2.090 3.289 1.821 3.020 1.552 2.697 1.230 16 4.203 2.477 3.920 2.220 3.645 1.969 3.369 1.719 3.094 1.469 2.763 1.168 16 4.203 3.316 3.920 3.058 3.645 2.808 3.369 2.558 3.094 2.307 2.763 2.007 17 4.296 3.150 4.014 2.
Outlines And Dimensions Indoor Unit MCK 020 / 025 / 030 / 040 / 050A/AR MCK 015 / 020 / 025B/BR MCK 010 / 015 / 020C/CR, M5CK 010 / 015C/CR MODEL MCK-A(All model) MCK-B(All model) MCK-C(All model) A 820 650 570 B 820 650 570 C 378 362 295 D 350 340 275 E 28 22 20 F 930 727 640 G 930 727 640 H 626 489 408 I 626 489 408 J 555 444 364 K 555 444 364 Note : All Dimension in mm Outdoor Unit MLC / M5LC 010 / 015C/CR Note : All Dimension in mm 82
M4LC 010 / 015B/BR MLC / M4LC 020 / 025B/BR DIMENSION 010 / 015B/BR 020 / 025B/BR A B C D E F G H J K L M N P Q R 740 494 270 266 233 474 52 60 54 166 92 348 318 129 482 68.5 840 646 330 297 309 626 46 90 64 177 106 408 378 124 492 78.
W iring Dia grams Diag Diagrams Cooling Only Indoor Unit Model : MCK 020 / 025A Outdoor Unit Model : MLC / M4LC 020 / 025B 84
Indoor Unit Model : MCK 030A Outdoor Unit Model : MLC 030B 85
Indoor Unit Model : MCK 030A Outdoor Unit Model : MLC / M4LC 030C 86
Indoor Unit Model : MCK 030A Outdoor Unit Model : MLC / M4LC 030C 87
Indoor Unit Model : MCK 040A Outdoor Unit Model : MLC / M4LC 035 / 040C 88
Indoor Unit Model : MCK 040 / 050A Outdoor Unit Model : MLC / M4LC 040 / 050C 89
Heat Pump Models Indoor Unit Model : MCK 020 / 025AR Outdoor Unit Model : MLC / M4LC 020 / 025BR 90
Indoor Unit Model : MCK 030AR Outdoor Unit Model : MLC 030BR 91
Indoor Unit Model : MCK 030AR Outdoor Unit Model : MLC / M4LC 030CR 92
Indoor Unit Model : MCK 030AR Outdoor Unit Model : MLC / M4LC 030CR 93
Indoor Unit Model : MCK 040AR Outdoor Unit Model : MLC / M4LC 035 / 040CR 94
Indoor Unit Model : MCK 040 / 050AR Outdoor Unit Model : MLC / M4LC 040 / 050CR 95
Cooling Only Indoor Unit Model : MCK 015B Outdoor Unit Model : MLC 015C 96
Indoor Unit Model : MCK 015B Outdoor Unit Model : M4LC 015B 97
Indoor Unit Model : MCK 020 / 025B Outdoor Unit Model : MLC / M4LC 020 / 025B 98
Heat Pump Indoor Unit Model : MCK 015BR Outdoor Unit Model : MLC 015CR 99
Indoor Unit Model : MCK 015BR Outdoor Unit Model : M4LC 015BR 100
Indoor Unit Model : MCK 020 / 025BR Outdoor Unit Model : MLC / M4LC 020 / 025BR 101
Cooling Only Indoor Unit Model : MCK / M5CK 010C Outdoor Unit Model : MLC / M5LC 010C 102
Indoor Unit Model : MCK / M5CK 015C Outdoor Unit Model : MLC/ M5LC 015C 103
Indoor Unit Model : MCK 010 / 015C Outdoor Unit Model : M4LC 010 / 015B 104
Indoor Unit Model : MCK 020C Outdoor Unit Model : MLC / M4LC 020B 105
Heatpump Indoor Unit Model : MCK / M5CK 010CR Outdoor Unit Model : MLC / M5LC 010CR 106
Indoor Unit Model : MCK / M5CK 015CR Outdoor Unit Model : MLC / M5LC 015CR 107
Indoor Unit Model : MCK 010 / 015CR REMARK: EITHER CN4 OR CN6 CAN BE CONNECTED AT ANY ONE TIME Outdoor Unit Model : M4LC 010 / 015BR 108
Indoor Unit Model : MCK 020CR Indoor Unit Model : MLC / M4LC 020BR 109
3 Phase For 2 & 2.
High Ambient Unit Outdoor Unit Model : MLC 020 / 025B (Cooling Only) 50Hz / 1 Phase / 220-240V Outdoor Unit Model : MLC 030C (Cooling Only) 50Hz / 1 Phase / 220 - 240V 111
Outdoor Unit Model : MLC 040 / 050C (Cooling Only) 50HZ / 30 Phase / 380 - 415V 112
Outdoor Unit Model : MLC 020 / 025BR (Heat Pump) 50HZ / 1 Phase / 220 - 240V Outdoor Unit Model : MLC 030CR (Heat Pump) 50HZ / 1 Phase / 220- 240V 113
Outdoor Unit Model : MLC 040 / 050CR (Heat Pump) 50HZ / 3 Phase / 380 - 415V 114
Low Ambient Unit (Optional) Outdoor Unit Model : M4LC 010 / 015B (Cooling Only) 50HZ / 1 Phase / 220 - 240V Outdoor Unit Model : MLC 010C (Cooling Only) 50HZ / 1 Phase / 220 - 240V 115
Outdoor Unit Model : MLC 015C (Cooling Only) 50HZ / 1 Phase / 220- 240V Outdoor Unit Model : MLC 020 / 025B (Cooling Only) 50HZ / 1 Phase / 220- 240V 116
Low Ambient Unit Outdoor Unit Model : MLC 010 / 015BR 50HZ / 1 Phase / 220 - 240V Outdoor Unit Model : MLC 020BR 50HZ / 1 Phase / 220 - 240V Outdoor Unit Model : MLC 025BR 50HZ / 1 Phase / 220 - 240V 117
Special Pr ecautions F or R407C Precautions For Special precautions when dealing with refrigerant R407C unit 1) What Is New Refrigerant R407C? R407C is a zeotropic refrigerant mixture which has zero ozone depletion potential and thus conformed to the Montreal Protocol regulation. It requires Polyol ester oil (POE) oil for its compressor’s lubricant. Its refrigerant capacity and performance are about the same as the refrigerant R22.
c) Ensure that the compressor is not expose to open air for more than the recommended time specified by its manufacturer (typically less than 10 minutes). Removed the seal-plugs only when the compressor is about to be brazed. d) The system should be thoroughly vacuumed to 1.0 Pa (-700mmHg) or lower. This vacuuming level is more stringent than R22 system so as to ensure no incompressible gas and moisture in the system.
Installa tion Of Indoor Unit Installation ! Caution : Sharp edges and coil surfaces are potential injury hazard. Avoid from contact with them. Preliminary Site Survey • • • • • • • Electrical supply and installation is to conform to local authority’s (e.g. National Electrical Board) codes and regulations. Voltage supply fluctuation must not exceed ± 10% of rated voltage. Electricity supply lines must be independent of welding transformer which can cause high supply fluctuations.
Unit Hanging Ceiling Board 35.0mm (MCK - A/ B) MCK-A/B/C • • • • • 30.0mm (MCK-C) Confirm the pitch of the hanging rod is 790.0mm X 620.5mm (MCK-A) / 600.0mm x 582.0 mm (MCK-B). Hold the unit and hang it on the hanging rod with the nut and washer. Adjust the unit height to 35.0 mm between the indoor unit bottom surface and the ceiling surface. Confirm with a level gauge that the unit is installed horizontally and tighten the nut and bolt to prevent unit falling and vibration.
Panel Installation • The front panel can only be fitted in one direction, follow the piping direction. (Follow piping arrow sticker on front panel). • Be sure to remove the installation template before installing the front panel. • Open the air intake grille by pulling back the catchers and remove it together with filter from panel. • Install the front frame panel onto the indoor unit by using 4 screws and tighten it completely to prevent cool air leakage.
Air Intake Grille Installation • Before installed the air intake grille, make sure the air filter is clip properly to the air intake grille. • Install the air intake grille together with the air filter to the front panel. • The grille can be fit in any direction, when selecting direction, the ceiling design and grille operability should be considered. • If the unit comes with ionizer filter (optional item), make sure to fix the ionizer filter to the air filter before installed the air intake grille.
Refrig er ant Piping W k efriger erant ork efrigerant Work or Refrigerant piping is important in particular. Refrigeration cycle of the split air conditioner is realized by the perfect piping work. Piping Length And Elevation If the piping is too long, both the capacity and reliability of the unit will drop.
MCK-A SERIES LENGTH 10m 15m 20m 35m 45m 20A/AR 325/75 400/150 - 25A/AR 190/250 380/500 - MODEL 30A/AR 650/250 900/500 1150/750 1500 2000 MODEL 20B/BR 325/75 400/150 25B/BR 290/500 480/750 MODEL 15C/CR 0/30 0/80 - 20C/CR 0 21/0 66/65 40A/AR 250 500 750 1500 2000 MCK-B SERIES LENGTH 10m 15m 15B/BR 325/75 400/150 MCK-C SERIES LENGTH 10m 12m 15m 10C/CR 0 36/55 - All Refrigerant Charge is in gram 125 50A/AR 250 500 750 1500 2000
Diagram shows typical charging method CAUTION FOR R407C Avoid prolong exposure of an opened compressor, or the internal part of refrigerant piping to moist air. The POE oil in the compressor and piping can absorb moisture from air. W iring Electrical Connections Wiring regulations on wire diameters differ from country to country. Please refer to your LOCAL ELECTRICAL CODES for field wiring rules. Be sure that installation is complied with such rules and regulations.
tor Lights Indicator Indica Wireless Remote Control (Universal Board) Cooling : LED Indicator Light Display POWER TIMER Heatpump : LED Indicator Light Display SLEEP POWER TIMER HEAT Operation/ Faulty Indication POWER ○ ○ ○ TIMER ○ SLEEP HEAT ○ Continuously Once every 3 second Twice every 3 sec 3 Times every 3 sec 4 Times every 3 sec ○ ○/● Timer on Sleep mode on Heat mode Frost prevention mode Compressor overload Pump fault Gas leak Room/ indoor/ outdoor coil sensor contact Loose/ short W
Phase Sequencer Normal Operation Reverve Phase S & T Phase Missing T Phase Missing S Phase Missing R Phase Missing Overload Sensor Missing LED_P (Red) On Blink Blink Blink Blink Blink Blink LED_R (Yellow) Blink On LED_S (Yellow) Blink Blink Blink On LED_T (Yellow) Blink Blink Blink On Notes: 1. “ - “ means LED off. 2. When R phase missing, no LED or buzzer will indicate the error, but relay 71 (Common) and 81 (NO) will cut off. 3.
Accessor yP ar ts Accessory Par arts Parts Fresh Air Intake For MCK-A Model Short Duct Specification • The indoor unit is provided with air discharge and air intake “knock-out”. hole for duct connection. However the connection of the short duct for air discharge is possible on only one side. • The use of short duct for air discharge will improve airflow distribution if there is an obstruction (such as alighting fixture) or in a long, narrow room or an L-shaped room.
Fresh Air Intake For MCK-C Unit Take off the panel from the indoor unit Figure 1 Remove the PE foam from the drain pan and another one on the unit. Remove the pre-punched panel on the CKC unit with a screwdriver. The diameter of the air intake knock out hole is 65mm Then, fix the fresh air kit (refer to parts list) to the hole. Finally, a flexible duct is connected to let the fresh air moving in.
Sealing Material • It is possible to seal one of the four air discharge outlet (sealing two or more air discharge outlet could cause a malfunction). • Remove the front panel and inserting the seal material into the air discharge outlet at the indoor unit to seal the air outlet. • The sealing material is the same length as the longer air discharge outlet. If it is desired to seal the shorter air discharge outlet, cut the sealing material to shorten it.
Remote Contr ol Oper ation Guide Control Opera Operation G7 Remote Controller 1 2 .Transmission source • 4 • 3 Temperature setting • • • Signal Transmission indication The source where the signal will be transmitted. To set the desired room temperature, press the button to increase or decrease the set temperature. The temperature setting range is from 16°C to 30°C (Optional setting 18°C to 30°C). Press both buttons simultaneously to toggle the temperature setting between °C and °F.
8 10 9 4 SENSOR ON/OFF AUTO 2 TEMP HIGH MED TIMER FAN ON/OFF 2 COOL FAN DRY HEAT MODE 3 FAN LOW 5 1 4 1 SWING TEMP 7 SLEEP 6 SWING SLEEP TIMER MODE 6 3 5 7 SLM MC-5300 (OPTIONAL) 1. “ON/OFF” switch • Press to start the air conditioner unit. • Press again to stop the unit. 6. “Sleep” mode • Press button to activate the sleep function can only be activated under “cool” or heating mode operation. activated under “cool” mode operation, the set temperature will increase 0.
Ser vicing And Maintenance Servicing ! Warning: Disconnect from main supply before servicing the air conditioner. The unit is designed to give long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Air filter (Indoor Unit) Maintenance Procedure 1. Remove the ionizer filter before cleaning the filter. 2.
Pr e Star Pre Startt Up Maintenance After Extended Shutdown • Inspect thoroughly and clean indoor and outdoor units. • Clean or replace air filter. • Clean condense drain line. • Clean clogged indoor and outdoor coils. • Check fan imbalance before operation. • Tighten all wire connections. • Check for refrigerant leakage, Note: The crankcase heater should be energized for at least 6 hours before start of operation (after extended shutdown).
Par artt List Unit - MCK - A/AR NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PARTS DESCRIPTION BASE PAN FAN MOTOR FAN MOTOR BUSH PLAIN WASHER FAN MOTOR WASHER BUTTON COUPLING TURBO FAN TOP COUPLING FLAT WASHER PLAIN WASHER SPRING WASHER HEXAGON BOLT HEXAGON BOLT EVAPORATOR COIL DRAIN PUMP BRACKET DRAIN PUMP DRAIN PUMP BUSH NO.
Panel ( Wireless Remote Control ) - MCK – A/AR NO 1 2 3 4 5 6 7 8 9 10 11 12 PART DESCRIPTION FRONT PANEL RECEIVER BRACKET DISCHARGE HOUSING A METAL LOUVER A DISCHARGE HOUSING B METAL LOUVER B DISCHARGE HOUSING D LOUVER BRACKET CRANK SHARF CRANK CONNECTOR CRANK CROSS SWING MOTOR NO.
Panel ( Wireless Remote Control ) - MCK – A/AR NO 1 2 3 4 5 6 7 8 9 10 11 PART DESCRIPTION FRON PANEL AIR FILTER DISCHARGE HOUSING A METAL LOUVER A DISCHARGE HOUSING C AIR SWING CAP DISCHARGE HOUSING D LOUVER BRACKET CRANK SHARF CRANK CONNECTOR CRANK CROSS NO.
Unit - MCK - B/BR NO 1 2 3 4 5 6 7 8 9 10 PART DESCRIPTION DRAIN PUMP FAN MOTOR PLATE, WIRE HANGER BRACKET A ASSY, VALVE PLATE BOTTOM ASSY. VALVE PLATE TOP ASSY PANEL B HANGER BRACKET B CONTROL BOX ASSY HOLDER GRILLE LONG NO.
Panel - MCK - B/BR NO 1 2 3 4 5 6 7 PART DESCRIPTION FRAME RECEIVER BRACKET LOUVER, SHORT LOUVER LOUVER HOLDER LOUVER CLIP PLATE, FIX NO.
Model : MCK / M5CK 010C/CR MCK / M5CK 015C/CR MCK 020C/CR NO 1 2 3 4 5 6 7 8 9 10 11 12 13 PART DESCRIPTION ASSY. BASE ASSY. CASING ASSY. COIL COVER, FAN BLOWER WHEEL, TURBO FAN FX330 TU YAMAHA PLATE, WIRE MOTOR, ACK20C-501 HONG LU BUSH, FAN MOTOR BUSH, FAN MOTOR RING ASSY., CONTROL BOX DRAIN PUMP PJV-0732 LEVEL SWITCH/ FLOAT SWITCH FS-06122A BUSH, WIRE NRID22XOD 36XT10.0-MODEL CE/SB NO. 14 15 16 17 PART DESCRITION BUSH, DRAIN PUMP ASSY. DRAIN PUMP SUPPORT BUCKET ASSY.
Panel : MCK / M5CK 010 / 015C/CR, MCK 020C/CR NO 1 2 3 4 5 6 7 8 9 10 PART DESCRIPTION FRAME INTAKE GRILLE FILTER GRILLE LOCK DISCHARGE, FOAM DISCHARGE, FOAM LED DISCHARGE, FOAM SHORT LOUVER LED LOUVER LINKAGE, COVER NO.
Model : MLC / M5LC 010C / 015C NO PART DESCRIPTION NO. PART DESCRITION 1 ASSY., BASE PAN 11 RIGHT PANEL 2 ASSY., CONDENSER COIL 12 ASSY., FRONT PANEL 3 VALVE BRACKET 13 ASSY. CONTROL PANEL 4 COMPRESSOR 14 ASSY., VALVE COVER 5 ASSY., PARTITION 15 ASSY., FRONT GRILLE 6 ASSY., CAP TUBE 16 PLASTIC, HANDLE 7 BRACKET, FAN MOTOR 17 RUBBER GROMMENT 8 FAN MOTOR 18 ASSY., FLARE VALVE 2 WAYS ¼” 9 FAN BLADE 19 ASSY., FLARE VALVE 3 WAYS 3/8” MLC 010C ASSY.
Model : MLC / M5LC 010CR / 015CR NO PART DESCRIPTION NO. PART DESCRITION 1 ASSY., BASE PAN 13 ASSY., FRONT PANEL 2 ASSY., CONDENSER COIL 14 ASSY. CONTROL PANEL 3 VALVE BRACKET 15 ASSY., VALVE COVER 4 COMPRESSOR 16 ASSY., FRONT GRILLE 5 ASSY., PARTITION 17 PLASTIC, HANDLE 6 ASSY., 4 WAY VALVE 18 RUBBER GROMMENT 7 ASSY., CAP TUBE 19 ASSY., FLARE VALVE 2 WAYS ¼” 8 BRACKET, FAN MOTOR 20 ASSY., FLARE VALVE 3 WAYS 3/8” 9 FAN MOTOR MLC 010CR 10 FAN BLADE ASSY.
Model : M4LC 010 / 015B NO PART DESCRIPTION NO. PART DESCRITION 1 BACK GRILLE 11 ASSY., CAP TUBE 2 TOP PANEL 12 ASSY., PARTITION 3 ASSY., CONDENSER COIL 13 ASSY., TERMINAL BOX PANEL 4 BRACKET, MOTOR MOUNTING 14 ASSY., SIDE PANEL 5 FAN MOTOR 15 ASSY., ACCESS PANEL 6 FAN BLADE 16 FLARE VALVE MOUNTING PLATE 7 ASSY., FRONT PANEL 17 ASSY., FLARE VALVE 2 WAYS ¼” 8 COMPRESSOR 18 ASSY., FLARE VALVE 3 WAYS 3/8” 9 RUBBER GROMMENT MLC 010B 10 ASSY., BASE PAN ASSY.
Model : M4LC 010 / 015BR NO PART DESCRIPTION NO. PART DESCRITION 1 BACK GRILLE 11 ASSY., CAP TUBE 2 TOP PANEL 12 ASSY., PARTITION 3 ASSY., CONDENSER COIL 13 ASSY., TERMINAL BOX PANEL 4 BRACKET, MOTOR MOUNTING 14 ASSY., SIDE PANEL 5 FAN MOTOR 15 ASSY., ACCESS PANEL 6 FAN BLADE 16 FLARE VALVE MOUNTING PLATE 7 ASSY., FRONT PANEL 17 ASSY., FLARE VALVE 2 WAYS ¼” 8 COMPRESSOR 18 ASSY., FLARE VALVE 3 WAYS 3/8” 9 RUBBER GROMMENT MLC 010BR 10 ASSY., BASE PAN ASSY.
Model : MLC / M4LC 020 / 025B/BR MLC 030B/BR NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PART DESCRIPTION BACK PANEL TOP PANEL COIL ASSY MOTOR MOUNTING BRACKET FAN MOTOR RING WASHER FAN BLADE SQUARE WASHER HEX NUT BLACK LABEL FRONT PANEL COMPRSSOR RUBBER GROMMENT WASHER NO.
Model : MLC / M4LC 030 / 035 / 040 / 050 / 061C/CR NO 1 2 3 4 5 6 7 8 9 10 PART DESCRIPTION BASE PAN FLARE VAL VE FLARE VAL VE PARTITION COMPRESSOR ACCESS PANEL ACCUMULATOR BACK PANEL TOP PANEL COIL ASSY NO.
Fresh Air Kit For MCK-C Models 149
©2005 McQuay International +1 (800) 432-1342 www .mcquay.