Specifications

15
M5MSX-2009
Installation Of Outdoor Unit
Installation Clearances
Dimensions A B C D
Minimum
Distance(mm) 300 1000 300 500
PLEASE
REMOVE
SERVICE
PANEL
PLEASE
REMOVE
ACCESS PANEL
& PLASTIC
VALVE COVER
WHEN
CONNECTING
THE PIPING
AND
CONNECTING
CORD.
PUSH & PULL UP
DC
A B
ELCATSBO
RIA NRUTER
ELCATSBO
ELCATSBO
The outdoor unit must be installed in such a way, so as to prevent short circuit of the hot discharged air or
obstruction to the smooth air flow. Please follow the installation clearance shown in the figures below. Select
the coolest possible place where intake air temperature is not greater than the outside air temperature
(maximum 45°C/113°F).
Note: If there is any obstacle higher than 2m (6.56ft), or if there is any obstruction at the upper part of the unit,
please allow more space than the figure indicated in the table shown below.
SERVICE SPACE
AIR DISCHARGE
Before installation the piping and connecting cord, please remove the access panel and plastic valve cover or
service panel for easy access and safety. Refer to figures shown below.
RETURN AIR
OBSTACLE
Application Information