Catalog DC Inverter Wall Mounted Models: M5MSX 020 AR M5MSX-2006
Table of Contents Nomenclature ........................................................................................................... 1 Features .................................................................................................................... 4 Application Information ........................................................................................... 5 Physical Data ............................................................................................................
Nomenc la tur e Nomencla latur ture Indoor Others A : First issue Controller Type L : Longertech T : OYLT Air Treatment Devices & Control I : Negative Ion with wireless controller N : NTP with wireless controller X : Oxygen unit Market Region C : Export with CE mark U : ETL spec Electrical A : 220-240V/1Ph/50Hz M 5 WM X 010 G - R A C I Model Type R : Heatpump Omitted if Cooling Only Series G : G series Capacity 010 : 9,000 Btu/h System X : DC Inverter Model Name WM : Wall Mounted Refrigerant 5 :
Outdoor Others A : First issue Controller Type L : Longertech T : OYLT Specification Variation O : Standard unit G : Low ambient unit H : High ambient unit I : Gold fins L : Long piping unit S : With H/L pressure switch X : Oxygen unit Market Region C : Export with CE marking E : Export without marking U : ETL spec Electrical A : 220-240V/1Ph/50Hz M 5 MS V 020 A - R A E O Model Type R : Heatpump Omitted if Cooling Only Series A : A series Capacity 020 : 18,000 Btu/h System X : DC Inverter Mode
Printed Circuit Board Compressor Marking DC Inverter Scroll CE ACOLA X X X X ACILA X X X X Refrigerant Control Nomenclature M5MSX Electronic Expansion Device LJ-DSCAA 020AR Heat Pump Model Handset Control Module LJID 1.
F ea tur es Fea eatur tures Higher Energy Savings The compressor in McQuay DC Multi Split Inverter is programmed to run at the optimum speed. The compressor speed is controlled by input frequency that varies according to the indoor load requirements. Once the indoor set temperature is achieved, the input frequency supply to the compressor will be reduced. Hence, less energy is required to maintain the unit operation and this will consume less energy.
Applica tion Inf or ma tion pplication Infor orma mation Operating Range Ensure the operating temperature is in allowable range Cooling only Outdoor temp. (°C DB) 46 Cautions: 35 STD The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. 19 15 24 Indoor temp. (°C WB) Heat pump Heating Cooling 6 Outdoor temp. (°C DB) Outdoor temp. (°C WB) 18 STD 46 35 STD 19 -9 15 21 27 15 Indoor temp. (°C WB) 24 Indoor temp.
Refrigerant Circuit Diagrams Model : M5WMX 010GR / 015GR c/w M5MSX 020AR 6
Controllers G11 Remote Controller Temperature Setting • On/Off Button To set the desired room temperature, press the button to increase or decrease the set temperature. • The temperature setting range is from 16°C to 30°C • Press both buttons simultaneously to toggle the temperature setting between °C and °F Press Once to start the air conditioner • Press again to stop the unit Personalised Setting Turbo Mode • • Press the TURBO button to achieve the required set temperature in a short time.
Ph ysical Da ta Physical Data General Data MODEL OUTDOOR UNIT M5MSX020AR INDOOR UNIT M5WMX010GR NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY M5WMX015GR 19000 (4500 - 21000) Btu/h W 5570 (1320 - 6150) Btu/h 21000 (4500 - 23000) W 6150 (1320 - 6740) NOMINAL TOTAL INPUT POWER (COOLING) W 1500 (355 - 1870) NOMINAL TOTAL INPUT POWER (HEATING) W 1630 (350 - 1950) NOMINAL RUNNING CURRENT (COOLING) A 6.75 (1.61 - 8.42) NOMINAL RUNNING CURRENT (HEATING) A 7.38 (1.59 - 8.
Electrical Data MODEL M5MSX020AR OUTDOOR UNIT M5WMX010GR INDOOR UNIT POWER SOURCE INDOOR MOTOR W 38 RATED RUNNING CURRENT A 0.19 MOTOR OUTPUT W 40 0.20 17 4P POLES B INSULATION GRADE V/Ph/Hz 230 / 1 / 50 W 130 RATED RUNNING CURRENT A 0.
Components Data MODEL OUTDOOR UNIT M5MSX020AR INDOOR UNIT M5WMX010GR 1 QUANTITY INDOOR FAN DIRECT DRIVE DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 INDUCTION 1 Q'TY IP24 INDEX OF PROTECTION (IP) PROPELLER FAN TYPE 1 QUANTITY GLASS REINFORCED ACRLY STYRENE RESIN OUTDOOR FAN MATERIAL DIRECT DRIVE DIAMETER 460 / 18.
P erf or mance Da ta Perf erfor ormance Data Capacity Rating Heating Cooling CONDITION Model M5MSX20A/AR with M5WMX-G/GR NOMINAL COOLING CAPACITY INDOOR OPERATING UNIT (M5WMX-G/GR) INDIVIDUAL INDOOR TOTAL BTU/h kcal/h INPUT RUNNING POWER CURRENT (W) KW (A) A B RATED RATED RATED (MAX) RATED (MAX) RATED (MAX) RATED (MAX) RATED 10 9000 - 9000 (10000) 2268 (2520) 2.64 (2.93) 870 (960) 3.92 (4.32) 15 12000 - 12000 (13000) 3024 (3276) 3.52 (3.81) 1145 (1440) 5.
Dimensional Da ta Data Indoor Unit Model : M5WMX 010GR / 015GR Outdoor Unit Model : M5MSX 020AR 12
W iring Dia grams Diag Indoor Unit Model : M5MSX 020AR 13
Troub leshooting oubleshooting When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself. No 1 2 3 Fault conditions The air conditioner unit will not resume after power failure.
Diagnostic Guideline By means of pressure readings • • High side Low side High side Low side High side Low side High side Low side High side Low side • • • • • • Probable cause Too high A little high Normal A little low Circuit Pressure Too low Data • • 1. 2. 3. 4. Overcharged with refrigerant. Non-condensable gases in refrigerant circuit (e.g. air) Obstructed air-intake / discharge. Hot air short circuiting in outdoor unit. 1.
By Means Of Diagnostic Flow Chart: Generally, there are two kinds of problems, i.e. starting failure and insufficient cooling/heating. “Starting failure” is caused by electrical defect while improper application or defects in refrigerant circuit causes “Insufficient cooling / heating”.
1 2 Condenser fan contactor Faulty Coil burnt Contact faulty Fan motor faulty Other electrical component faulty Compressor contactor Change the contactor Faulty Change the contacts Repair or change the motor contactor Repair or change if necessary Coil burnt Contact faulty Open compressor windings Incorrect wiring The most common causes of air conditioner failure to “start” are : a) Voltage not within ±10% of rated voltage. b) Power supply interrupted. c) Improper control settings.
ii ) Diagnosis of Refrigerant Circuit / Application There might be some causes where the unit starts running but does not perform satisfactorily, i.e. insufficient cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge air as well as running current.
Insufficient heating Air circulation Restricted Indoor / outdoor coil dirty (clogged) Indoor air filter dirty Fan motor malfunction Obstruction at air inlet / outlet of indoor / outdoor unit High heating load Refrigerant circuit Windows / doors wide open Refrigerant short charge or refrigerant leakage Restriction e.g. at strainer, capillary, filter dryer, etc.
Exploded Vie w and P ar ts List iew Par arts M5WMX 010GR / 015GR Related Model No. Description ASSY, CHASSIS 10/15G MOTOR, MWMX10/15G-501-WL 17W WELLING BLOWER CROSS FLOW WM10/15G G97-717.5 FAN BUSH C/FLOW BLACK ASSY.
M5MSX 020AR 19 16 14 7 17 No.
Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquayup.com. © 2006 McQuay International +1 (800) 432-1342 www.mcquay.