Catalog DC Inverter Multi Split Models: M5MSX 020 A/AR M5MSX 025 A/AR M5MSX 030 A/AR M5MSX-2008
Table of Contents Nomenclature ....................................................................................................................1 -Product Line up Features ............................................................................................................................4 Application Information......................................................................................................
Nomenclature Indoor Others A : First Issue Controller Type L : Longertech E-Scroll T : OYL R&D E-Scroll Air Treatment Devices & Control I : Negative Ion with wireless controller N : NTP with wireless controller Market Region C : Export with CE mark U : ETL spec Electrical A : 220 – 240V/1Ph/50Hz M 5 WM X 020 G - R A C I Model Type R : Heatpump Omitted if Cooling Only Series C : C series Capacity 020 : 20,000 Btu/h Product type X : DC Inverter Model Name WM : Wall Mounted Refrigerant 5 : R410A B
Outdoor Others A : First issue Controller Type L : Longertech E-Scroll T : OYL R&D E-Scroll Specifications Variation O : Standard Unit I : Gold Fin Market Region C : Export with CE mark Electrical A : 220 – 240V/1Ph/50Hz M 5 MS X 020 A - R A C O L Model Type R : Heatpump Omitted if Cooling Only Series A : A series Capacity 20 : 20,000 Btu/h Product type X : DC Inverter Model Name MS : Multi Split Condensing Unit Refrigerant 5 : R410A Brand M : Mcquay 2 A
Nomenclature G11 VA2.0 N e ga ti v e I on N a n o F i l t er C ool i ng Onl y X X 030A ACOLA X X 020AR ACOLA X X 025AR ACOLA X X 030AR ACOLA X X CE Marking X X X X X X X X X X X X X X X 3 Drain Elbow W/O CE Marking DC Inv.Scroll Comp. DC Inv.
Features Higher Energy Savings The compressor in McQuay DC Multi Split Inverter is programmed to run at the optimum speed. The compressor speed is controlled by input frequency that varies according to the indoor load requirements. Once the indoor set temperature is achieved, the input frequency supply to the compressor will be reduced. Hence, less energy is required to maintain the unit operation and this will consume less energy.
Application Information Operating Range Ensure the operating temperature is in allowable range Cooling only Outdoor temp. (°C DB) 46 Cautions: 35 STD The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. 19 15 24 Indoor temp. (°C WB) Heat pump Heating Cooling 6 Outdoor temp. (°C DB) Outdoor temp. (°C WB) 18 STD 46 35 STD 19 -9 15 21 27 15 Indoor temp. (°C WB) 24 Indoor temp.
Refrigerant Circuit Diagram Model : M5MSX 020A 6
Model : M5MSX 020AR 7
Model : M5MSX 025A 8
Model : M5MSX 025AR 9
Model : M5MSX 030A 10
Model : M5MSX 030AR 11
Controllers G11 Remote Controller Temperature Setting To set the desired room temperature, press the button to increase or decrease the set temperature. On/Off Button • Press Once to start the air conditioner • The temperature setting range is from 16°C to 30°C • Press again to stop the unit • Press both buttons simultaneously to toggle the temperature setting between °C and °F Personalised Setting • Turbo Mode • Press the TURBO button to achieve the required set temperature in a short time.
Installation Safety Precautions Before installing the air conditioner unit, please read the following safety precautions carefully Warning • Installation and maintenance should be performed by qualified persons who are familiar with local code and regulation, and experienced with this type of appliance. • All field wiring must be installed in accordance with the national wiring regulation.
Installation of the indoor unit The indoor unit must be installed in such a way so as to prevent short circuit of the cool discharged air with the hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit where there could be direct sunlight shinning on it. Also, this location must be suitable for piping drainage and be away from doors or windows. 50.0 mm 50.
Installation Diagram L4 VERTICAL HEIGHT DIFFERENCE MAX. H L3 L2 INDOOR UNIT L1 OUTDOOR UNIT Indoor unit combination for outdoor unit M5MSX 020A/AR, M5MSX025A/AR and M5MSX030A/AR Indoor units with model name M5WMX 010G/GR, M5WMX015G/GR and M5WMX020G/GR could be coupled with this outdoor unit. The following table shows the possible coupling combinations available.
Installation of outdoor unit The outdoor unit must be installed in such a way, so as to prevent short circuit of the hot discharged air or obstruction to the smooth air flow. Please follow the installation clearance shown in the figures below. Select the coolest possible place where intake air temperature is not greater than the outside air temperature (maximum 45°C/113°F). Note: If there is any obstacle higher than 2m (6.
Refrigerant piping work Piping length and elevation If the pipe is too long, both capacity and reliability of the unit will drop. As the number of bends increases, resistance to the flow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective. Always choose the shortest path and follow the recommentdations as tabulated below. Item 1 2 3 Model M5MSX020A/AR (1 to 2) M5MSX025A/AR (1 to 3) M5MSX030A/AR (1 to 4) Coupling Model Max.
Piping Works Cutting copper tube • Do not use contaminated or damaged copper tubing. Do not remove plastic, rubber plugs and brass nuts from the valves, fittings, tubings and coils until you are ready to connect suction or liquid line into valves or fittings. • If any brazing work is required, ensure that the nitrogen gas passed through coil and joints while the brazing work is being done. This will eliminate soot formation on the inside walls of the copper tubings.
Electrical wiring connection IMPORTANT : The figures shown in the table are for information purpose only. They should be checked and selected to comply with the local/national codes of regulations. This is also to the type of installation and conductors used.
Model Voltage range M5WMX010G/15G M5WMX020G/GR 220V-240V / 1 Ph / 50Hz + 3.0 3 1.5 2.5 4 4 25 2 Power supply cable size (mm ) Number of wire 2 Interconnection cable size (mm ) Number of wire Recommended time delay fuse for O/D unit • The table above shows the electrical wire sizing for different connection cables. If the length of the cable is more than 2m, use cable with bigger size. • The figures shown in the table are for information purpose only.
Vacuuming and charging Purging the piping and indoor unit Except for the outdoor unit which is pre-charged with refrigerant R22, the indoor unit and the refrigerant connection pipes must be air-purged because the air containing moisture that remains in the refrigerant cycle maycause malfunction of the compressor. • Make sure all pipes are connected securely to the outdoor and indoor valves. • Remove the caps from the flare valve and the service.
Indicator Lights IR signal receiver When an infrared remote control operating signal has been transmitted, the signal receiver on indoor unit will made a (beep) sound to comfirm acceptance of the signal transmission. The table shows the LED indicator lights for the indoor air conditioner unit under normal operation and fault conditions. The LED indicator lights are located at the middle of the air conditioner unit for 5WMX-G/GR serires.
Air conditioner unit opeartion • When the air humidity is high, the unit can operate in dry mode. Press button and choose . • If the room temperature is 2°C higher than the set temperature, the air conditioner will operate under cooling mode until it reaches within the 2°C range of difference compared to the set temperature before it converts to dry mode. • If the room temperature is within the 2°C range of difference compared to the set temperature, it will directly operate under dry mode.
Electrostatic Filter Dual Action Electrostatic Air Purifying and Deodorizing Filter Media and Filter Frame Action 1Electtrostatic air purifying filter Action 2Deodorizing filter Removes microscopic dust, smoke and small invisible particules to keep the room air clean with pre-charged electrostatic polypropylene filter. Remove unwanted smells and odors in the air and keeps the room air fresh with activated carbon filter. HOW TO INSTALL Open the front frame grille.
Engineering and Physical Data General Data - Cooling Only MODEL OUTDOOR UNIT M5MSX 020A INDOOR UNIT NOMINAL COOLING CAPACITY M5WMX 010G M5WMX 015G Btu/h 19000 (4500 - 21000) W 5570 (1320 - 6150) NOMINAL TOTAL INPUT POWER W 1500 (355 - 1870) NOMINAL RUNNING CURRENT A 6.75 (1.61 - 8.42) 220 - 240 / 1 /50 POWER SOURCE V/Ph/Hz REFRIGERANT TYPE CONTROL INDOOR UNIT AIR FLOW R410A OPERATION WIRELESS LCD REMOTE CONTROL HIGH CFM / L/s 300 / 141.6 330 / 155.7 MEDIUM CFM / L/s 250 / 118.
General Data - Cooling Only MODEL OUTDOOR UNIT M5MSX 025A INDOOR UNIT NOMINAL COOLING CAPACITY M5WMX 010G M5WMX 015G Btu/h 22000 (9000 - 24000) W 6450 (2640 - 7030) NOMINAL TOTAL INPUT POWER W 1815 (590 - 2200) NOMINAL RUNNING CURRENT A 8.13 (3.18 - 9.86) 220 - 240 / 1 /50 POWER SOURCE V/Ph/Hz REFRIGERANT TYPE CONTROL INDOOR UNIT AIR FLOW R410A AIR DISCHARGE OPERATION LCD WIRELESS REMOTE CONTROL HIGH CFM / l /s 300 / 141.6 330 / 155.7 MEDIUM CFM / l /s 250 / 118.0 260 / 122.
General Data - Cooling Only MODEL OUTDOOR UNIT M5MSX 025A INDOOR UNIT M5WMX 020G Btu/h 22000 (9000 - 24000) W 6450 (2640 - 7030) NOMINAL TOTAL INPUT POWER W 1815 (590 - 2200) NOMINAL RUNNING CURRENT A 8.13 (3.18 - 9.86) 220 - 240 / 1 /50 NOMINAL COOLING CAPACITY POWER SOURCE V/Ph/Hz REFRIGERANT TYPE CONTROL INDOOR UNIT AIR FLOW R410A OPERATION LCD WIRELESS REMOTE CONTROL HIGH CFM / l /s 550 / 236.0 MEDIUM CFM / l /s 440 / 207.7 LOW CFM / l /s 370 / 174.
General Data - Cooling Only MODEL OUTDOOR UNIT M5MSX030A INDOOR UNIT NOMINAL COOLING CAPACITY M5WMX010G M5WMX015G Btu/h 26000 (4500 - 29000) W 7620 (1320 - 8500) NOMINAL TOTAL INPUT POWER W 2350 (400 - 2815) NOMINAL RUNNING CURRENT A 10.44 (1.81 - 12.
General Data - Heatpump MODEL OUTDOOR UNIT M5MSX 020AR INDOOR UNIT M5WMX 010GR Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY M5WMX 015GR 19000 (4500 - 21000) W 5570 (1320 - 6150) Btu/h 21000 (4500 - 23000) W 6150 (1320 - 6740) NOMINAL TOTAL INPUT POWER (COOLING) W 1500 (355 - 1870) NOMINAL TOTAL INPUT POWER (HEATING) W 1630 (350 - 1950) NOMINAL RUNNING CURRENT (COOLING) A 6.75 (1.61 - 8.42) NOMINAL RUNNING CURRENT (HEATING) A 7.38 (1.59 - 8.
General Data - Heatpump MODEL OUTDOOR UNIT M5MSX 025AR INDOOR UNIT M5WMX 010GR Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY M5WMX 015GR 22000 (9000 - 24000) W 6450 (2640 - 7030) Btu/h 25000 (4500 - 26000) W 7330 (1320 - 7620) NOMINAL TOTAL INPUT POWER (COOLING) W 1815 (590 - 2200) NOMINAL TOTAL INPUT POWER (HEATING) W 1900 (400 - 2155) NOMINAL RUNNING CURRENT (COOLING) A 8.13 (3.18 - 9.86) NOMINAL RUNNING CURRENT (HEATING) A 8.52 (1.81 - 9.
General Data - Heatpump MODEL OUTDOOR UNIT M5MSX 025AR INDOOR UNIT M5WMX 020GR Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY 22000 (9000 - 24000) W 6450 (2640 - 7030) Btu/h 25000 (4500 - 26000) W 7330 (1320 - 7620) NOMINAL TOTAL INPUT POWER (COOLING) W 1815 (590 - 2200) NOMINAL TOTAL INPUT POWER (HEATING) W 1900 (400 - 2155) NOMINAL RUNNING CURRENT (COOLING) A 8.13 (3.18 - 9.86) NOMINAL RUNNING CURRENT (HEATING) A 8.52 (1.81 - 9.
General Data - Heatpump MODEL OUTDOOR UNIT M5MSX 030AR INDOOR UNIT M5WMX 015GR M5WMX 010GR Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY W 7620 (1320 - 8500) Btu/h 28000 (4500 - 32000) W 8210 (1320 - 9380) NOMINAL TOTAL INPUT POWER (COOLING) W 2350 (400 - 2815) NOMINAL TOTAL INPUT POWER (HEATING) W 2030 (400 - 2755) NOMINAL RUNNING CURRENT (COOLING) A 10.44 (1.81 - 12.50) A 9.0 (1.81 - 12.
Components Data MODEL OUTDOOR UNIT M5MSX 020A INDOOR UNIT M5WMX 010GR TYPE 1 QUANTITY INDOOR FAN INDOOR FAN MOTOR 1 ACRYLO NITRILE STYRENE MATERIAL DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION Q'TY 1 INDEX OF PROTECTION (IP) IP24 TYPE OUTDOOR FAN M5WMX 015G ANTI FUNGUS CROSS FLOW FAN PROPELLER FAN QUANTITY 1 MATERIAL GLASS REINFORCED ACRLY STYRENE RESIN DRIVE DIRECT DIAMETER OUTDOOR FAN MOTOR 460 / 18.
Components Data MODEL M5MSX 025A OUTDOOR UNIT INDOOR UNIT M5WMX 010G TYPE 1 QUANTITY INDOOR FAN INDOOR FAN MOTOR M5WMX 015G ANTI FUNGUS CROSS FLOW FAN 1 ACRYLO NITRILE STYRENE MATERIAL DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.
Components Data MODEL OUTDOOR UNIT M5MSX 025A INDOOR UNIT M5WMX 020G TYPE INDOOR FAN INDOOR FAN MOTOR ANTI FUNGUS CROSS FLOW FAN QUANTITY 1 MATERIAL ACRYLO NITRILE STYRENE DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.
Components Data MODEL OUTDOOR UNIT M5MSX030A INDOOR UNIT M5WMX010G TYPE INDOOR FAN MOTOR 1 MATERIAL DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.
Components Data MODEL M5MSX 020AR OUTDOOR UNIT INDOOR UNIT M5WMX 010GR TYPE 1 QUANTITY INDOOR FAN INDOOR FAN MOTOR DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 INDUCTION TYPE 1 Q'TY INDEX OF PROTECTION (IP) IP24 PROPELLER FAN QUANTITY 1 MATERIAL GLASS REINFORCED ACRLY STYRENE RESIN DRIVE DIRECT DIAMETER OUTDOOR FAN MOTOR 460 / 18.
Components Data MODEL OUTDOOR UNIT M5MSX 025AR INDOOR UNIT M5WMX 010GR TYPE QUANTITY INDOOR FAN INDOOR FAN MOTOR M5WMX 015GR ANTI FUNGUS CROSS FLOW FAN 1 MATERIAL 1 ACRYLO NITRILE STYRENE DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.
Components Data MODEL OUTDOOR UNIT M5MSX 025AR INDOOR UNIT M5WMX 020GR TYPE INDOOR FAN INDOOR FAN MOTOR ANTI FUNGUS CROSS FLOW FAN QUANTITY 1 MATERIAL ACRYLO NITRILE STYRENE DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.
Components Data MODEL M5MSX 030AR OUTDOOR UNIT M5WMX 010GR INDOOR UNIT TYPE INDOOR FAN MOTOR 1 DIRECT DRIVE DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.
Performance Data Capacity Rating Heating Cooling CONDITION Specifications for M5MSX020A/AR with M5WMX-G/GR INPUT RUNNING POWER CURRENT NOMINAL COOLING CAPACITY INDOOR OPERATING UNIT INDIVIDUAL INDOOR TOTAL BTU/h kcal/h KW (W) (A) A (BTU/h) B (BTU/h) RATED RATED RATED (MAX) RATED (MAX) RATED (MAX) RATED (MAX) RATED 10 9000 - 9000 (10000) 2268 (2520) 2.64 (2.93) 870 (960) 3.92 (4.32) 15 12000 - 12000 (13000) 3024 (3276) 3.52 (3.81) 1145 (1440) 5.15 (6.
Heating Cooling CONDITION Specifications for M5MSX025A/AR with M5WMX-G/GR INDOOR OPERATING NOMINAL COOLING CAPACITY INDIVIDUAL INDOOR TOTAL BTU/h kcal/h INPUT RUNNING POWER CURRENT (W) KW (A) A B C RATED RATED RATED RATED (MAX) RATED (MAX) RATED (MAX) RATED (MAX) RATED 10 9000 - - 9000 (10000) 2268 (2520) 2.64 (2.93) 592 (724) 3.18 (3.39) 15 12000 - - 12000 (13500) 3024 (3402) 3.52 (3.96) 969 (1207) 4.44 (5.
Heating Cooling CONDITION Specifications for M5MSX030A/AR with M5WMX-G/GR NOMINAL COOLING CAPACITY INDOOR OPERATING UNIT (M5WMX-G/GR) INDIVIDUAL INDOOR TOTAL BTU/h kcal/h INPUT RUNNING POWER CURRENT KW (W) (A) A B C C RATED RATED RATED RATED RATED (MAX) RATED (MAX) RATED (MAX) RATED (MAX) RATED 10 9500 - - - 9500 (10800) 2394 (2722) 2.78 (3.17) 860 (1007) 3.82 (4.47) 15 12000 - - - 12000 (14400) 3024 (3629) 3.52 (4.22) 1159 (1743) 5.14 (7.73) (11.
Dimensional Data Indoor Unit Model : M5WMX 010 / 015G/GR Note: Dimension in mm 44
Model : M5WMX 020G/GR Note: Dimension in mm 45
Outdoor Unit Model : M5MSX 020A/AR V U E K V U A D G T T P I H N O L W M S S S F C J O R B Dimension M5MSX 020A/AR A B C D E F G H I J K L M N O P Q R S T U V W 939 333 756 855 392 733 603 328 303 370 362 248 449 160 115 53 141 90 64 126 32 15 23 (37) (13,1)(29,8)(33,7)(15,4)(28,9)(23,7)(12,9)(11,9)(14,6)(14,3) (9,8) (17,7) (6,3) (4,5) (2,1) (5,6) (3,5) (2,5) (5) (1,3) (0,6) (0,9) Outdoor Unit Model : M5MSX 025A/AR V U E K V U A D T G T I P H N L O SSS SS W M F C J O
Outdoor Unit Model : M5MSX 030A/AR A V U E K V U D T G T I P H N L O SS S SS SS W M F C J O R B Dimension M5MSX 030A/AR A B C D E F G H I J K L M N O P Q R S T U V W 939 333 756 855 392 733 603 328 303 370 362 298 449 160 115 53 141 42 64 126 32 15 23 (37) (13,1)(29,8)(33,7)(15,4)(28,9)(23,7)(12,9)(11,9)(14,6)(14,3)(11,7)(17,7) (6,3) (4,5) (2,1) (5,6) (1,7) (2,5) (5) (1,3) (0,6) (0,9) 47
Electrical Data Electrical Data - Cooling Only MODEL OUTDOOR UNIT M5MSX 020A M5WMX 010G INDOOR UNIT M5WMX 015G INSULATION GRADE POWER SOURCE INDOOR MOTOR E 230 / 1 / 50 V/Ph/Hz RATED INPUT POWER W 38 RATED RUNNING CURRENT A 0.19 MOTOR OUTPUT W 40 0.20 17 POLES 4P INSULATION GRADE POWER SOURCE OUTDOOR MOTOR RATED INPUT POWER B 230 / 1 / 50 V/Ph/Hz W 130 RATED RUNNING CURRENT A 0.
Electrical Data - Cooling Only MODEL OUTDOOR UNIT M5MSX 025A INDOOR UNIT M5WMX 020G INSULATION GRADE POWER SOURCE INDOOR MOTOR E 230 / 1 / 50 V/Ph/Hz RATED INPUT POWER W 60 RATED RUNNING CURRENT A 0.31 MOTOR OUTPUT W 40 POLES 4P INSULATION GRADE POWER SOURCE OUTDOOR MOTOR RATED INPUT POWER B 230 / 1 / 50 V/Ph/Hz W 140 RATED RUNNING CURRENT A 0.
Electrical Data - HeatPump MODEL M5MSX 025AR OUTDOOR UNIT INSULATION GRADE POWER SOURCE INDOOR MOTOR E W 38 RATED RUNNING CURRENT A 0.19 MOTOR OUTPUT W POLES 40 0.20 17 4P INSULATION GRADE B V/Ph/Hz OUTDOOR MOTOR RATED INPUT POWER 230 / 1 / 50 W 140 RATED RUNNING CURRENT A 0.58 MOTOR OUTPUT W 80 V/Ph/Hz 0-300/3/0-100 µF - RATED INPUT POWER (COOLING) W 1690 RATED INPUT POWER (HEATING) W 1700 RATED RUNNING CURRENT (COOLING) A 7.5 RATED RUNNING CURRENT (HEATING) A 7.
Electrical Data - Cooling Only MODEL OUTDOOR UNIT M5MSX030A M5WMX 010G INDOOR UNIT INSULATION GRADE POWER SOURCE INDOOR MOTOR M5WMX 020G E 230 / 1 / 50 V/Ph/Hz RATED INPUT POWER W 38 RATED RUNNING CURRENT A 0.19 40 0.20 0.31 MOTOR OUTPUT W 17 17 40 POLES 60 4P INSULATION GRADE POWER SOURCE B 230 / 1 / 50 V/Ph/Hz OUTDOOR MOTOR RATED INPUT POWER W 170 RATED RUNNING CURRENT A 0.
Wiring Diagrams Indoor Unit Model : M5MSX 020AR 52
Indoor Unit Model : M5MSX 025AR 53
Model : M5MSX 030AR 54
Servicing and Maintenance Service Parts Maintenance Procedures 1. Remove any dust adhering to the filter by using a vacuum cleaner or wash in lukewarm water (below 40°C) with a neutral Indoor air filter cleaning detergent. 2. Rinse the filter well and dry before placing it back onto the unit. Period At least once every 2 weeks. More frequently if necessary. 3. Do not use gasoline, volatile substances or chemicals to clean the filter. 1.
Troubleshooting If there is any malfunction of the air conditioner unit detected, please sitch off the main power supply immediately before proceeding with the following troubleshooting procedures as safety precautions. The following are some common fault conditions and simple troubleshooting tips. If encounter any faulty conditions which are not listed, please contact nearest dealer or service maintenance. DO NOT attempt to troubleshoot the unit by yourself.
Normal Running Mode condition If the air conditioner unit has no faulty indications and the compressor is running at normal mode, the outdoor P.C. Board’s LED indication will blink at a slower pace. The table below shows the significant meaning of different running mode and limitation for this air conditioner unit. One must not attempt to see the LED indication blinking unless instructed to do so.
Troubleshooting Progress If the air conditioner is not operating normally, One should follow the troubleshooting steps as stated in the flow chart below .
Check Point (3) – IPM Board Step-by-step troubleshooting guide for identifying IPM Board error.
Exploded View and Parts List Model : M5WMX 010 / 015 G/GR No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Description ASSY, CHASSIS 10/15G Motor WMX10/15G 17w Welling BLOWER,CROSS FLOW G97-717.5 SUNWILL FAN BUSH C/FLOW BLACK ASSY, INDOOR COIL - WM10GR ASSY, INDOOR COIL - WM15GR PIPING CLAMP ASSY, DRAIN PAN 10/15G DRAIN HOSE WM10/15(600mmL) ASSY, CONTROL BOX COVER (AP) ASSY, CONTROL BOX 10G-ION OYLT ASSY, CONTROL BOX 10GR-ION OYLT ASSY, CONTROL BOX 15G-ION OYLT ASSY, CONTROL BOX 15GR-ION OYLT ASSY.
Model : M5WMX 020G/GR No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Description Assy, Chassis WM20/25G Motor, MWMX20/20G FAN CROSS FLOW, WM20/25F Fan Bush C/Flow Grey Assy, Coil WM20G/GR / 5WM25G/R Clamp, Piping 20/25G Assy, Drain Pan 20/25G Drain Hose Assy WM20C/25C(700mmL) Assy, Control Box Cover 20/25G (EC) ASSY, CONTROL BOX (ION 5WMX 20G) ASSY, CONTROL BOX (ION 5WMX 20GR) ASSY,F/COVER-A ASSY, AIR DISCHARGE 20/25G FILTER, NANOSILVER 20/25G (WITH FRAME) FILTER, NANOVIS 20/25G (WITH FRAME) Motor, MP35
Model : M5MSX 020A/AR No 1 2 3 4 5 6 7 8 Description Assy, Base Pan (5SLX20/25CR) Assy, Condenser Coil (5MSX20AR) Panel, Partition Assy, Comprssor 5CS130XCC03 Bracket Motor (SL25C/28C/CR) Motor, M5MSX20AR-501-K 64W Fan Propeller, Ø460 0Z40700 ASSY.
Model : M5MSX 025A/AR No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Description Part Number ASSY., BASE PAN (5MSX25/30AR) ASSY., COMP. MOUNT. PLATE ASSY., CONDENSER COIL PANEL, PARTITION COMPRESSOR, ASSY 5KD240XAA21 MATSUSHITA VALVE, REV 4 WAY SHF-7H-34U(RK) SHANHUA ASSY., VALVE BRACKET ASSY., FILTER DRIER LIQUID RECEIVER, QFQ1.0-B-02 TONG LI TUBE, LIQ. REC.
MODEL : M5MSX 030A/AR No.