MVCU - 2004 Vertical Condensing Unit Models: MVCU 025 A/AR MVCU 030 A/AR MVCU 035 A/AR MVCU 040 A/AR MVCU 050 A/AR MVCU 060 A/AR
Contents Features ......................................................................................................................... 1 Specifications .................................................................................................................2 Operation Range ............................................................................................................7 Refrigerant Circuit ..............................................................................................
Features Space Saving The smaller base size and vertical air discharge allow compact location on multi-unit installation. Power Source Single phase unit is available in MVCU025A. Three phase units are available in MVCU030A, 035A, 040A, 050A & 060A. Wide Range MVCU units are available in 2.5 to 6 HP to meet various needs in residential and light commercial applications.
Specifications WALL MOUNTED – VERTICAL CONDENSING UNIT (COOLING ONLY) MODEL INDOOR UNIT OUTDOOR UNIT COIL FIN TUBE MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AREA DIMENSION kcal/h W Btu/h W A V/Ph/Hz cfm / L/s W A MWM 031F MVCU 030A 7560 8792 30000 2880 5.1 220-240 / 1 / 50 R22 / OUTDOOR CAP.TUBE ANTI FUNGUS CROSS FLOW FAN 580 / 274 4 POLES x 25W 57 0.24 740 / 349 4 POLES x 45W 71 0.30 THERMAL OVERLOAD RELAY SEAMLESS COPPER TUBE INNER GROOVED mm/in mm/in 7.0 / 0.276 0.
CEILING CONVERTIBLE – VERTICAL CONDENSING UNIT (COOLING ONLY) MODEL INDOOR UNIT MCM 025D MCM 030D MCM 040D MCM 040D MCM 050D MCM 062C OUTDOOR UNIT MVCU 025A MVCU 030A MVCU 035A MVCU 040A MVCU 050A MVCU 060A 14364 NOMINAL kcal/h 6048 7560 9073 10080 12348 COOLING W 7034 8792 10551 11723 14360 16705 CAPACITY Btu/h 24000 30000 36000 40000 49000 57000 W 2490 2941 3397 3227 4285 5111 A 12.6 5.2 5.9 5.8 8.2 8.
CEILING CASSETTE A SERIES – VERTICAL CONDENSING UNIT (COOLING ONLY) INDOOR UNIT OUTDOOR UNIT NOMINAL COOLING CAPACITY NOMINAL TOTAL POWER NOMINAL TOTAL CURRENT POWER SOURCE REFRIGERANT / CONTROL AIR FLOW FAN MOTOR RATED INPUT POWER RATED RUNNING CURRENT MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AREA HEIGHT DIMENSION WIDTH ( ) - WITH PANEL DEPTH WEIGHT (UNIT + PANEL) SOUND PRESSURE LEVEL - H / M / L ROOM TEMPERATURE CONTROL AIR DISCHARGE OPERATION CONDENSATE DRAIN SIZE AIR FILTER P
CEILING CASSETTE B SERIES – VERTICAL CONDENSING UNIT (COOLING ONLY) MODEL INDOOR UNIT OUTDOOR UNIT COIL INDOOR UNIT TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR FIN TUBE FAN NOMINAL COOLING CAPACITY NOMINAL TOTAL POWER NOMINAL TOTAL CURRENT POWER SOURCE REFRIGERANT / CONTROL AIR FLOW FAN MOTOR RATED INPUT POWER RATED RUNNING CURRENT MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AREA HEIGHT DIMENSION WIDTH ( ) - WITH PANEL DEPTH WEIGHT (UNIT + PANEL) SOUND PRESSURE LEVEL
CEILING CONCEALED – VERTICAL CONDENSING UNIT (COOLING ONLY) MODEL INDOOR UNIT OUTDOOR UNIT MCC 025C MCC 030C MVCU 025A MVCU 030A MCC 040C MCC 050C MCC 060C MVCU 035A MVCU 040A MVCU 050A MVCU 060A NOMINAL kcal/h 6048 7813 9073 10080 12348 14364 COOLING W 7034 9086 10551 11723 14360 16705 CAPACITY Btu/h 24000 31000 36000 40000 49000 57000 EFFECTIVE TOTAL POWER W 2494 3070 3570 3400 4460 5160 NOMINAL TOTAL POWER W 2540 3179 3685 3515 4624 5376 NOMINAL TOTAL
Operating Range Ensure the operating temperature is in allowable range. Cooling only Cooling Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. Outdoor temp. (°CDB) 51.7 50 40 STD 35 30 20 10 0 -5 -10 10 15 19 20 24 25 30 Indoor temp.
MODEL : MVCU 025A Refrigerant Circuit 8
9 MODEL : MVCU 030A/035A/040A/050A/060A
Outlines And Dimensions MODEL : MVCU 025 / 030 / 035A MODEL MVCU 025 / 030 / 035A A B C D E F G 841 572 572 168 236 168 166 All dimensions in mm 10
MODEL : MVCU 040 / 050 / 060A MODEL A B C D E F G MVCU 040A 984 762 275 225 762 225 275 MVCU 050 / 060A 1086 762 275 225 762 225 275 All dimensions in mm 11
Wiring Diagrams WALL MOUNTED INDOOR UNIT MODEL : MWM 025F OUTDOOR UNIT MODEL : MVCU 025A 12
INDOOR UNIT MODEL : MWM 031F OUTDOOR UNIT MODEL : MVCU 030A 13
CEILING CONVERTIBLE INDOOR UNIT MODEL : MCM 025D OUTDOOR UNIT MODEL : MVCU 025A 14
INDOOR UNIT MODEL : MCM 030D OUTDOOR UNIT MODEL : MVCU 030A 15
INDOOR UNIT MODEL : MCM 040D OUTDOOR UNIT MODEL : MVCU 035A 16
INDOOR UNIT MODEL : MCM 040 / 050D OUTDOOR UNIT MODEL : MVCU 040 / 050A 17
INDOOR UNIT MODEL : MCM 062C OUTDOOR UNIT MODEL : MVCU 060A 18
CEILING CASSETTE A SERIES INDOOR UNIT MODEL : MCK 025A OUTDOOR UNIT MODEL : MVCU 025A 19
INDOOR UNIT MODEL : MCK 030A OUTDOOR UNIT MODEL : MVCU 030A 20
INDOOR UNIT MODEL : MCK 040A OUTDOOR UNIT MODEL : MVCU 035A 21
INDOOR UNIT MODEL : MCK 040 / 050A OUTDOOR UNIT MODEL : MVCU 040 / 050A 22
CEILING CASSETTE B SERIES INDOOR UNIT MODEL : MCK 025B OUTDOOR UNIT MODEL : MVCU 025A 23
INDOOR UNIT MODEL : MCK 030B OUTDOOR UNIT MODEL : MVCU 030A 24
CEILING CONCEALED INDOOR UNIT MODEL : MCC 025C OUTDOOR UNIT MODEL : MVCU 025A 25
INDOOR UNIT MODEL : MCC 030C OUTDOOR UNIT MODEL : MVCU 030A 26
INDOOR UNIT MODEL : MCC 040C OUTDOOR UNIT MODEL : MVCU 035A 27
INDOOR UNIT MODEL : MCC 040 / 050 / 060C OUTDOOR UNIT MODEL : MVCU 040 / 050 / 060A 28
Installation (1) Installation Of VCU • The unit should be installed in accordance with all national and local codes and regulations which govern the installation of this type of equipment. • The VCU unit must not be installed with any duct work on the air discharge side. The outdoor fan is a propeller type and is not designed to operate against any additional external static.
Piping Sizes (Brazed Valve) Piping sizes are as follows: MODEL Liquid (mm/in) Suction (mm/in) MVCU 025A 9.52 (3/8) 15.88 (5/8) MVCU 030A 9.52 (3/8) 15.88 (5/8) MVCU 035 / 040A 9.52 (3/8) 19.05 (3/4) MVCU 050A 9.52 (3/8) 19.05 (3/4) MVCU 060A 12.7 (1/2) 22.23 (7/8) (3) Wiring Electrical Connections • Wiring regulations on wire diameters differ from country to country. Please refer to your LOCAL ELECTRICAL CODES for field wiring rules. Be sure that installation comply with such rules and regulations.
(5) Additional Charge • The refrigerant gas has already charged into the outdoor unit. For the piping length of 5m. Additional refrigerant charge after vacuuming is not necessary. • When the piping length is more than 5m, please use the table below (unit in gram). MODEL MVCU 025A MVCU 030A MVCU 035 / 040A MVCU 050A MVCU 060A 7m 76 100 100 100 220 10m 190 250 250 250 550 15m 380 500 500 500 1100 20m 570 750 750 750 1650 35m 1500 1500 1500 3300 Diagram shows typical charging method.
Service And Maintenance Warning: Disconnect from main supply before servicing the air conditioner. The unit is designed to give long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Air filter (Indoor Unit) Indoor unit Condense Drain Pan & Pipe Indoor Fan Maintenance Procedure 1. Remove the ionizer filter before cleaning the filter. 2.
The design of the VCU outdoor series allows servicing to be carried out readily and easily. The removal of the top side, front and back panel make almost every part accessible. Under normal circumstances, these outdoor units only require a check and cleaning of air intake coil surface once quarterly.
Troubleshooting When any air-conditioner malfunction is noted, immediately switch off the power supply to the unit, and contact the local dealer, if necessary. Some simple troubleshooting tips are given below : FAULT CAUSE 1. Fan does not work 3 minutes after starting • Protection against the frequent starting. Wait 3 or 4 minutes. 2. The air conditioning unit does not work • Power failure or you must be replaced the fuse. • The power plug is disconnected.
FOR COOLING ONLY MODELS DIAGNOSIS BY FLOW CHART The following chart are efficient checking procedures for troubleshooting when these fan-coil units are coupled with the condensing units using standard wiring. For dual circuited models, perform the procedures for each circuit.
INSUFFICIENT COOLING Insufficient Cooling Compressor Cycling Cycling On Dual Pressure Switch Tripping High Discharge Pressure or Low Suction Pressure Clogged Capillary or Pressure Switch Switch Faulty Running Overcurrent Relay For Compressor Tripping High Voltage or Low Voltage Single-Phase High Discharge Pressure And High Suction Pressure Loose Connections Discharge Gas Thermostat or Internal Thermostat Tripping High Discharge Pressure And Low Suction Pressure Refrigerant Short Charge or Refrig
HIGH SUCTION PRESSURE High Suction Pressure Low Evaporator Air Inlet Temp. Excessive Fresh Air Intake Reduce The Fresh Air Intake Insufficient Duct Insulation Reinforce The Duct Insulation Defective Compressor Valve Change Or Repair The Compressor Overcharged Refrigerant Purge The Refrigerant LOW SUCTION PRESSURE Low Suction Pressure Clogged Air Filter Evaporator Air Flow Restricted Evaporator Air Inlet Temp.
Parts List MODEL : MVCU 025A NO 1 2 3 4 5 6 7 8 9 10 DESCRIPTION NO 11 12 13 14 15 16 17 18 COIL ASSY TOP PANEL FAN GUARD FAN MOTOR FAN BLADE FAN COVER CONTROL BOX ASSY SERVICE PANEL BASE PANEL MIDDLE COIL GUARD 38 DESCRIPTION SIDE COIL GUARD COMPRESSOR ASSY, TUBE HEADER TO DISCHARGE DISCHARGE TUBE ASSY SUCTION TUBE ASSY TERMINAL BOX COVER DISCHARGE VALVE SUCTION VALVE
MODEL : MVCU 030 / 035A NO 1 2 3 4 5 6 7 8 9 10 DESCRIPTION NO 11 12 13 14 15 16 17 18 COIL ASSY TOP PANEL FAN GUARD FAN MOTOR FAN BLADE FAN COVER CONTROL BOX ASSY SERVICE PANEL BASE PANEL MIDDLE COIL GUARD 39 DESCRIPTION SIDE COIL GUARD COMPRESSOR DISCHARGE TUBE ASSY SUCTION TUBE ASSY ASSY, TUBE HEADER TO DISCHARGE TERMINAL BOX COVER SUCTION VALVE DISCHARGE VALVE
MODEL : MVCU 040 / 050 / 060A NO 1 2 3 4 5 6 7 8 9 10 DESCRIPTION NO 11 12 13 14 15 16 17 18 19 COIL ASSY TOP PANEL FAN GUARD FAN MOTOR FAN BLADE FAN COVER CONTROL BOX ASSY SERVICE PANEL BASE PANEL MIDDLE COIL GUARD 40 DESCRIPTION SIDE COIL GUARD COMPRESSOR DISCHARGE TUBE ASSY SUCTION TUBE ASSY ASSY, TUBE HEADER TO DISCHARGE TERMINAL BOX COVER TOP COIL INSULATION SUCTION VALVE DISCHARGE VALVE
REGISTERED ISO 9002 ©2004 McQuay International +1 (800) 432-1342 www.mcquay.