MCM - 2004 Ceiling Exposed Split Systems Models: MCM 020 MCM 025 MCM 030 MCM 040 MCM 050 MCM 061 MCM 062 D/DR D/DR D/DR D/DR D/DR C/CR C/CR REGISTERED ISO 9002 ©2004 McQuay International +1 (800) 432-1342 www.mcquay.
Contents Special Features ........................................................................................................... 2 Specifications ................................................................................................................ 3 Noise Level ................................................................................................................... 15 Operation Range ...................................................................................................
Special Features Ultra Slim New Stylish Design Profile This unit is contemporary in design and match even the most up to date interior decor. The slim, round profile and compact design of this unit adds a touch of elegance to every decor. No indoor connection pipe and hanger bracket are visible. Ceiling And Floor Convertible With Space Saving Installation This unit is designed for ceiling exposed type and floor exposed type with a very economical and space saving installation.
Specifications Cooling Only (R22) MODEL INDOOR UNIT OUTDOOR UNIT FAN NOMINAL COOLING CAPACITY POWER SOURCE REFRIGERANT / CONTROL AIR FLOW FAN MOTOR kcal/h W Btu/h V/Ph/Hz cfm/cmm 50 Hz 60 Hz W (50/60Hz) A (50/60Hz) COIL FAN COMPRESSOR POWER SOURCE mm/in COMPRESSOR TYPE CAPACITOR - µF 1∅ / < 3∅ > LOCK ROTOR AMPERE - A 1∅ / < 3∅ > RATED RUNNING CURRENT - A 1∅ / < 3∅ > RATED INPUT POWER - W 1∅ / < 3∅ > PROTECTION DEVICE POWER SOURCE FAN TYPE / DRIVE BLADE MATERIAL DIAMETER 2 2 m /ft mm/in mm/in mm/
Heat Pump (R22) MODEL MCM030DR MCM040DR INDOOR UNIT MCM020DR MCM025DR OUTDOOR UNIT MLC020BR MLC025BR MLC030BR MLC030CR MLC035CR MLC040CR 5040 6048 6552 7560 8820 10080 MCM050DR MLC050CR NOMINAL kcal/h COOLING W 5862 7034 7620 8792 10258 11723 14068 CAPACITY Btu/h 20000 24000 26000 30000 35000 40000 48000 NOMINAL kcal/h 5292 6300 7056 8064 9072 10332 12096 HEATING W 6155 7327 8206 9379 10551 12016 14068 CAPACITY NOMINAL TOTAL POWER (COOLING) - 1∅ [ 3∅
Cooling Only (R22) MODEL INDOOR UNIT MCM061C OUTDOOR UNIT MLC061C NOMINAL kcal/h 14110 COOLING W 16410 CAPACITY Btu/h 56000 NOMINAL TOTAL POWER W 5593 NOMINAL TOTAL CURRENT A 9.4 V/Ph/Hz 220 - 240 / 1 / 50 POWER SOURCE REFRIGERANT / CONTROL R22 / CAPILLARY TUBE IN INDOOR SOUND LEVEL (dBA) 1550 / 732 HIGH 56 MED 53 46 FAN MOTOR 2 x 4 POLES x 80 W RATED INPUT POWER W 327 RATED RUNNING CURRENT A 1.40 DIAMETER mm/in 9.52 / 3/8 THICKNESS mm/in MATERIAL S.I.G.C 0.
Cooling Only (R22) MODEL INDOOR UNIT OUTDOOR UNIT FAN NOMINAL COOLING CAPACITY NOMINAL TOTAL POWER NOMINAL TOTAL CURRENT POWER SOURCE REFRIGERANT / CONTROL AIR FLOW SOUND LEVEL (dBA) COIL FIN TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR INDOOR UNIT TUBE FAN MOTOR RATED INPUT POWER RATED RUNNING CURRENT MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AREA HEIGHT DIMENSION WIDTH DEPTH WEIGHT CONTROL ROOM TEMPERATURE OPERATION CONDENSATE DRAIN SIZE AIR FILTER PACKING HEIGHT D
Heat Pump (R22) MODEL INDOOR UNIT OUTDOOR UNIT FAN NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY NOMINAL TOTAL POWER (COOLING) NOMINAL TOTAL POWER (HEATING) NOMINAL TOTAL CURRENT (COOLING) NOMINAL TOTAL CURRENT (HEATING) POWER SOURCE REFRIGERANT / CONTROL AIR FLOW SOUND LEVEL (dBA) COIL FIN TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR INDOOR UNIT TUBE FAN MOTOR RATED INPUT POWER RATED RUNNING CURRENT MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AREA HEIGHT DIMENSION
Heat Pump (R22) MODEL MCM062CR INDOOR UNIT MLC061CR OUTDOOR UNIT NOMINAL kcal/h 14110 COOLING W 16410 CAPACITY Btu/h 56000 NOMINAL kcal/h 14110 HEATING W 16410 Btu/h 56000 NOMINAL TOTAL POWER (COOLING) W 6195 NOMINAL TOTAL POWER (HEATING) W 5265 NOMINAL TOTAL CURRENT (COOLING) A 30.6 NOMINAL TOTAL CURRENT (HEATING) A 26.
Cooling Only (R407C) MODEL INDOOR UNIT OUTDOOR UNIT P IP E O U T D O O R U N IT C O IL F IN TUBE FAN COM P.
Heat Pump (R407C) MODEL INDOOR UNIT OUTDOOR UNIT COIL FIN TUBE COIL FIN TUBE PIPE OUTDOOR UNIT FAN COMP.
Cooling Only (R407C) MODEL FAN NOMINAL COOLING CAPACITY NOMINAL TOTAL POWER NOMINAL TOTAL CURRENT POWER SOURCE REFRIGERANT / CONTROL AIR FLOW SOUND LEVEL (dBA) COIL FIN FIN COIL TUBE FAN COM PRESSOR INDOOR UNIT TUBE FAN MOTOR RATED INPUT POWER RATED RUNNING CURRENT MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AREA HEIGHT DIMENSION WIDTH DEPTH WEIGHT CONTROL ROOM TEMPERATURE OPERATION CONDENSATE DRAIN SIZE AIR FILTER PACKING HEIGHT DIMENSION WIDTH DEPTH POWER SOURCE COMPRES
Cooling Only (R407C) MODEL MCM062C INDOOR UNIT OUTDOOR UNIT M4LC060C M4LC061C NOMINAL kcal/h 13860 13610 COOLING W 16120 15830 CAPACITY Btu/h 55000 54000 NOMINAL TOTAL POWER W 6027 5645 NOMINAL TOTAL CURRENT A 10.2 POWER SOURCE R407C / CAPILLARY TUBE IN INDOOR REFRIGERANT / CONTROL SOUND LEVEL (dBA) cfm / L/s 1550 / 732 HIGH 56 MED 53 46 LOW 2 x 4 POLES x 80 W FAN MOTOR RATED INPUT POWER W 327 RATED RUNNING CURRENT A 1.40 DIAMETER mm/in 9.
Heat Pump (R407C) MODEL INDOOR UNIT MCM061CR OUTDOOR UNIT M4LC061CR NOMINAL kcal/h 14110 HEATING W 16410 CAPACITY Btu/h 56000 NOMINAL kcal/h 13610 COOLING W 15830 CAPACITY Btu/h 54000 NOMINAL TOTAL POWER (COOLING) W 5645 NOMINAL TOTAL POWER (HEATING) W 5145 NOMINAL TOTAL CURRENT (COOLING) A 9.5 NOMINAL TOTAL CURRENT (HEATING) A 9.
Heat Pump (R407C) MODEL INDOOR UNIT MCM062CR OUTDOOR UNIT M4LC061CR NOMINAL kcal/h 14110 HEATING W 16410 CAPACITY Btu/h 56000 NOMINAL kcal/h 13610 COOLING W 15830 CAPACITY Btu/h 54000 NOMINAL TOTAL POWER (COOLING) W 5645 NOMINAL TOTAL POWER (HEATING) W 5145 NOMINAL TOTAL CURRENT (COOLING) A 9.5 NOMINAL TOTAL CURRENT (HEATING) A 9.
Noise Level Model MCM020D/DR MCM025D/DR MCM030D/DR MCM040D/DR MCM050D/DR MCM061/62 C/CR Speed High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Overall A (dBA) Noise Criteria 45 42 36 48 47 45 45 44 43 51 48 46 51 48 46 34 32 26 46 43 37 51 50 47 48 47 45 53 51 50 53 51 50 45 43 36 47 45 39 51 50 48 48 47 45 51 50 49 51 50 49 49 46 40 46 42 35 50 49 47 47 46 44 50 49 48 50 49 48 52 49 42 41 38 31 45 44 41 43 4
MCM020D/DR NC Curves 70 Sound pressure level (dB, ref 20 Pa) 60 50 NC-50 NC-45 High f an 40 NC-40 NC-35 M edium fan 30 NC-30 Low fan NC-25 20 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) M easured in anecho ic ro o m at 1m in fro nt o f the unit and 0.
MCM030D/DR NC Curves 70 Sound pres s ure lev el (dB, ref 20 Pa) 60 50 N C -5 0 N C -4 5 Hig h f an 40 N C -4 0 M ed ium f an N C -3 5 Lo w f an 30 N C -3 0 N C -2 5 20 N C -2 0 10 0 125 250 500 1000 2000 4000 8000 Oc tav e-band f requenc y (Hz ) M eas ured in anec ho ic ro o m at 1m in fro nt o f the unit and 1m belo w the air dis c harge o pening MCM040D/DR NC Curves 70 Sound pres s ure lev el (dB, ref 20 Pa) 60 50 N C -5 0 Hig h f an N C -4 5 M ed ium f an 40 N C -4 0 Lo w f an N
MCM050D/DR NC Curves 70 Sound pres s ure lev el (dB, ref 20 Pa) 60 50 N C -5 0 Hig h f an N C -4 5 M ed ium f an 40 N C -4 0 Lo w f an N C -3 5 30 N C -3 0 N C -2 5 20 N C -2 0 10 0 125 250 500 1000 2000 4000 8000 Oc tav e-band f requenc y (Hz ) M eas ured in anec ho ic ro o m at 1m in fro nt o f the unit and 1m belo w the air dis c harge o pening MCM061/62 C/CR NC Curves 70 Sound pressure level (dB, ref 20 Pa) 60 NC-55 50 NC-50 High fan NC-45 M edium fan 40 NC-40 Low fan NC-35 3
Operating Range Ensure the operating temperature is in allowable range. Cooling only Cooling Caution : Outdoor temp. (°CDB) 54 HIGH AMBIENT UNIT 46 The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. 35 STD 19 LOW AMBIENT KIT -5 15 24 Indoor temp. (°CWB) Heat pump Cooling Heating 54 6 Outdoor temp. (°CDB) Outdoor temp. (°CWB) 18 STD -9 HIGH AMBIENT UNIT 46 35 STD 19 LOW AMBIENT KIT -5 15 21 15 27 24 Indoor temp.
Refrigerant Circuit MODEL : MCM020D – MLC/ M4LC020B MODEL : MCM025D – MLC/ M4LC025B MCM030D – M4LC030B Page 20
MODEL : MCM030D – MLC/ M4LC030C MCM040D – MLC035C MCM040D – MLC/ M4LC040C MCM050D – MLC/ M4LC050C MODEL : MCM061/ 62C – MLC061C, M4LC60C/ 061C Page 21
MODEL : MCM020DR – MLC/ M4LC020BR MODEL : MCM025DR – MLC/M4LC025BR MCM030DR – MLC030BR Page 22
MODEL : MCM030DR – MLC/ M4LC030CR MCM040DR – MLC035CR MCM040DR – MLC/ M4LC040CR MCM050DR – MLC/ M4LC050CR NOTE : A4LC30CR WITH TXV ONLY MODEL : MCM061 / 062CR – MLC061C/ M4LC060CR Page 23
Performance Table COOLING ONLY (R22) MODEL : MCM020D / MLC020B Indoor DB °C 26.7 Indoor WB °C 13.9 15 18 19.4 20 22 24 Capacity kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 19.4 5.144 5.056 5.550 4.859 6.658 4.319 7.175 4.068 7.397 3.960 8.135 3.601 8.874 3.241 25 4.937 4.868 5.290 4.688 6.254 4.199 6.704 3.970 6.900 3.856 7.556 3.478 8.212 3.099 30 4.752 4.700 5.058 4.536 5.893 4.091 6.283 3.883 6.457 3.764 7.039 3.368 7.620 2.972 35 4.568 4.532 4.827 4.384 5.532 3.983 5.862 3.795 6.014 3.671 6.
MODEL : MCM030D / MLC030C Indoor DB °C 26.7 Indoor WB °C 13.9 15 18 19.4 20 22 24 Capacit y kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC Outdoor DB, °C 19.4 7.784 7.088 8.383 6.942 10.017 6.543 10.779 6.358 11.106 6.278 12.195 6.013 13.284 5.747 25 7.460 6.910 7.981 6.743 9.403 6.289 10.066 6.077 10.357 5.980 11.326 5.655 12.296 5.331 30 7.170 6.751 7.622 6.566 8.854 6.062 9.429 5.827 9.688 5.714 10.551 5.337 11.414 4.959 35 6.880 6.592 7.263 6.389 8.306 5.835 8.792 5.577 9.019 5.448 9.775 5.018 10.
MODEL : MCM050D / MLC050C Indoor DB °C 26.7 Indoor WB °C 13.9 Capacit y kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 15 18 19.4 20 22 24 Outdoor DB, °C 19.4 12.749 11.176 14.011 10.996 17.454 10.505 19.060 10.275 19.748 10.177 22.043 9.849 24.338 9.522 25 12.256 11.014 13.300 10.774 16.149 10.119 17.478 9.814 18.098 9.681 20.163 9.239 22.228 8.797 30 11.815 10.869 12.665 10.575 14.984 9.775 16.066 9.402 16.624 9.238 18.485 8.694 20.345 8.149 35 11.374 10.724 12.030 10.377 13.819 9.431 14.654 8.
COOLING ONLY (R407C) MODEL : MCM020D / M4LC020B Indoor DB °C 26.7 Indoor WB °C 13.9 15 18 19.4 20 22 24 Capacit y kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 19.4 4.706 4.627 5.078 4.446 6.092 3.952 6.565 3.722 6.768 3.623 7.444 3.295 8.120 2.966 25 4.517 4.454 4.841 4.290 5.722 3.842 6.134 3.633 6.314 3.529 6.914 3.182 7.514 2.836 30 4.348 4.300 4.628 4.151 5.392 3.743 5.749 3.553 5.908 3.444 6.440 3.082 6.972 2.719 35 4.180 4.147 4.416 4.012 5.062 3.644 5.363 3.473 5.503 3.359 5.967 2.981 6.431 2.
MODEL : MCM040D / M4LC040C Indoor DB °C 26.7 Indoor WB °C 13.9 15 18 19.4 20 22 24 Capacity kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 19.4 9.586 9.188 10.505 8.993 13.009 8.462 14.178 8.214 14.678 8.108 16.348 7.753 18.018 7.399 25 9.233 8.918 10.004 8.723 12.105 8.191 13.086 7.942 13.533 7.807 15.024 7.355 16.515 6.903 Outdoor DB, °C 40 46 7.877 7.150 7.726 7.013 8.341 7.571 7.547 6.850 9.608 8.721 7.058 6.406 10.199 9.257 6.829 6.199 10.521 9.549 6.657 6.043 11.594 10.523 6.083 5.522 12.667 11.
HEAT PUMP MODEL – R22 MODEL : MCM020DR / MLC020BR Indoor DB °C 26.7 Indoor WB °C 13.9 15 18 19.4 20 22 24 Capacity kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 19.4 5.106 4.748 5.600 4.633 6.949 4.318 7.578 4.172 7.848 4.109 8.747 3.899 9.646 3.689 25 4.907 4.625 5.318 4.503 6.439 4.172 6.962 4.018 7.205 3.943 8.013 3.694 8.821 3.445 (COOLING MODE) 30 4.729 4.514 5.066 4.388 5.984 4.042 6.412 3.881 6.630 3.796 7.357 3.512 8.084 3.228 35 4.552 4.404 4.814 4.272 5.528 3.912 5.862 3.744 6.055 3.648 6.
MODEL : MCM040DR / MLC040CR Indoor DB °C 26.7 Indoor WB °C 13.9 Capacit y kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 15 18 19.4 20 22 24 19.4 9.748 9.649 10.889 9.438 14.000 8.861 15.452 8.592 16.074 8.476 18.148 8.092 20.222 7.707 25 9.448 9.370 10.381 9.136 12.926 8.498 14.113 8.200 14.669 8.063 16.523 7.607 18.376 7.152 (COOLING MODE) 30 9.180 9.121 9.928 8.867 11.967 8.173 12.918 7.850 13.415 7.694 15.072 7.175 16.728 6.656 35 8.913 8.872 9.475 8.597 11.008 7.849 11.723 7.500 12.161 7.325 13.
HEATING MODE – R22 MODEL : MCM020DR / MLC020BR (HEATING MODE) -9.0 -5.0 6.0 12.0 15.0 18.3 kW 15.0 17.0 19.0 21.0 24.0 26.7 TC 3.552 3.561 3.570 3.579 3.466 3.366 SC 3.552 3.561 3.570 3.579 3.466 3.366 TC 3.858 3.823 3.789 3.754 3.702 3.655 SC 3.858 3.823 3.789 3.754 3.702 3.655 TC 4.698 5.183 5.669 6.155 5.259 4.452 SC 4.698 5.183 5.669 6.155 5.259 4.452 TC 5.156 5.110 5.064 5.018 4.949 4.887 SC 5.156 5.110 5.064 5.018 4.949 4.887 TC 5.
MODEL : MCM040DR / MLC040CR (HEATING MODE) -9.0 -5.0 6.0 12.0 15.0 18.3 kW 15.0 17.0 19.0 21.0 24.0 26.7 TC 6.456 6.337 6.218 6.099 6.108 6.117 SC 6.456 6.337 6.218 6.099 6.108 6.117 TC 7.779 7.709 7.640 7.570 7.465 7.371 SC 7.779 7.709 7.640 7.570 7.465 7.371 TC 11.419 11.618 11.817 12.016 11.388 10.822 SC 11.419 11.618 11.817 12.016 11.388 10.822 TC 13.404 13.284 13.165 13.045 12.866 12.704 SC 13.404 13.284 13.165 13.045 12.866 12.
HEATPUMP MODEL – R407C MODEL : MCM020DR / M4LC020BR Indoor DB °C 26.7 Indoor WB °C 13.9 15 18 19.4 20 22 24 Capacity kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 19.4 4.595 4.273 5.040 4.169 6.254 3.886 6.820 3.754 7.063 3.698 7.873 3.509 8.682 3.321 25 4.416 4.162 4.786 4.053 5.795 3.755 6.266 3.616 6.484 3.549 7.212 3.325 7.939 3.101 (COOLING MODE) 30 4.256 4.063 4.559 3.949 5.385 3.638 5.771 3.493 5.967 3.416 6.622 3.160 7.276 2.905 35 4.097 3.964 4.333 3.845 4.975 3.521 5.275 3.369 5.450 3.283 6.
HEATPUMP MODEL – R407C MODEL : MCM040DR / M4LC040CR Indoor DB °C 26.7 Indoor WB °C 13.9 Capacity kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 15 18 19.4 20 22 24 19.4 9.504 9.408 10.616 9.202 13.650 8.639 15.065 8.377 15.672 8.264 17.694 7.889 19.717 7.514 25 9.212 9.136 10.122 8.908 12.603 8.285 13.760 7.995 14.303 7.861 16.110 7.417 17.917 6.973 (COOLING MODE) Outdoor DB, °C 35 40 46 8.690 7.958 7.223 8.650 7.921 7.190 9.238 8.459 7.679 8.382 7.676 6.967 10.733 9.828 8.921 7.653 7.008 6.361 11.
HEATING MODE – R407C MODEL : MCM020DR / M4LC020BR (HEATING MODE) -9.0 -5.0 6.0 12.0 15.0 18.3 kW 15.0 17.0 19.0 21.0 24.0 26.7 TC 3.214 3.222 3.230 3.238 3.136 3.045 SC 3.214 3.222 3.230 3.238 3.136 3.045 TC 3.490 3.459 3.428 3.396 3.349 3.307 SC 3.490 3.459 3.428 3.396 3.349 3.307 TC 4.250 4.690 5.129 5.569 4.758 4.028 SC 4.250 4.690 5.129 5.569 4.758 4.028 TC 4.665 4.623 4.581 4.540 4.477 4.421 SC 4.665 4.623 4.581 4.540 4.477 4.421 TC 4.
MODEL : MCM040DR / M4LC040CR (HEATING MODE) -9.0 -5.0 6.0 12.0 15.0 18.3 kW 15.0 17.0 19.0 21.0 24.0 26.7 TC 6.456 6.337 6.218 6.099 6.108 6.116 SC 6.456 6.337 6.218 6.099 6.108 6.116 TC 7.779 7.709 7.639 7.570 7.465 7.371 SC 7.779 7.709 7.639 7.570 7.465 7.371 TC 11.418 11.617 11.817 12.016 11.387 10.822 SC 11.418 11.617 11.817 12.016 11.387 10.822 TC 13.403 13.284 13.164 13.044 12.865 12.704 SC 13.403 13.284 13.164 13.044 12.865 12.
INDOOR UNIT Model: MCM - D SERIES (COOLING ONLY AND HEAT PUMP) MODEL A B C D E F G H I J K L M MCM020D/DR 1174 75 1082 68 58 156 1214 57 670 216 319 879 517 MCM025D/DR 1174 75 1082 68 58 156 1214 57 670 216 319 879 517 MCM030D/DR 1174 75 1082 68 93 156 1214 57 670 216 319 879 517 Page 37 MCM040D/DR 1674 75 1582 68 93 156 1714 57 670 216 319 1379 517 MCM050D/DR 1674 75 1582 68 93 156 1714 57 670 216 319 1379 517
MODEL : MCM061C/CR MODEL : MCM062C/CR CE 62C A(GRILL) 1750 B 40 C 36 D 1930 E 1830 F 680 G 352 H 292 Page 38 I 285 J 140 K 1880 L 250 O 126 T 132 X 508
OUTDOOR UNIT MODEL : MLC020/ 025 B/BR, M4LC020/ 025 B/BR, MLC030B/BR Note : Dimension in mm MODEL : MLC030/ 035/ 040/ 050 C/CR, M4LC030/ 040/ 050 C/CR, M4LC060C Caution Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places.
MODEL : MLC / M4LC061 C/CR Page 40
Wiring Diagrams COOLING ONLY INDOOR UNIT MODEL : MCM020/025D OUTDOOR UNIT MODEL : MLC/M4LC020/ 025B Page 41
INDOOR UNIT MODEL : MCM030D OUTDOOR UNIT MODEL : MLC030B Page 42
INDOOR UNIT MODEL : MCM030D OUTDOOR UNIT MODEL : MLC/M4LC030C Page 43
INDOOR UNIT MODEL : MCM040D OUTDOOR UNIT MODEL : MLC035C Page 44
INDOOR UNIT MODEL : MCM040/ 050D OUTDOOR UNIT MODEL : MLC/M4LC040/ 050C Page 45
INDOOR UNIT MODEL : MCM061/ 062C OUTDOOR UNIT MODEL : M4LC060C Page 46
INDOOR UNIT MODEL : MCM061/ 062C OUTDOOR UNIT MODEL: MLC/ M4LC061C Page 47
HEAT PUMP INDOOR UNIT MODEL : MCM020/ 025DR OUTDOOR UNIT MODEL: MLC/ M4LC020/ 025BR Page 48
INDOOR UNIT MODEL : MCM030DR OUTDOOR UNIT MODEL: MLC030BR Page 49
INDOOR UNIT MODEL : MCM030DR OUTDOOR UNIT MODEL: MLC/ M4LC030CR Page 50
INDOOR UNIT MODEL : MCM040DR OUTDOOR UNIT MODEL: MLC035CR Page 51
INDOOR UNIT MODEL : MCM040/ 050DR OUTDOOR UNIT MODEL: MLC/ M4LC040/ 050CR Page 52
INDOOR UNIT MODEL : MCM061/ 062CR OUTDOOR UNIT MODEL: MLC/M4LC061CR Page 53
INDOOR UNIT MODEL : MCM061/ 062CR OUTDOOR UNIT MODEL: MLC/ M4LC060CR Page 54
ATTACHMENT 60HZ OUTDOOR UNIT MODEL : MLC 30C (COOLING ONLY) 60HZ / 1 PHASE / 208 ~230V MODEL : MLC040/ 050C (COOLING ONLY) 60HZ / 3 PHASE / 200 ~230V MODEL : MLC040/ 050CR (COOLING ONLY) 60HZ / 3 PHASE / 200 ~230V Page 55
3 PHASE FOR 2 & 3 HP OUTDOOR UNIT MODEL : MLC/ M4LC020/ 025B (COOLING ONLY) 3 PHASE / 50 HZ / 380 ~ 415V MODEL : MLC/ M4LC030C (COOLING ONLY) 3 PHASE / 50 HZ / 380 ~ 415V Page 56
MODEL : MLC/ M4LC020/ 025BR (HEAT PUMP) 3 PHASE / 50HZ / 380 ~ 415V MODEL : MLC/ M4LC030CR (HEAT PUMP) 3 PHASE / 50HZ / 380 ~ 415V Page 57
HIGH AMBIENT UNIT OUTDOOR UNIT MODEL : MLC020/ 025B (COOLING ONLY) 50HZ / 1 PHASE / 220 – 240V, 60HZ / 1 PHASE / 208 – 230V OUTDOOR UNIT MODEL : MLC030C (COOLING ONLY) 50HZ / 1 PHASE / 220 – 240V, 60HZ / 1 PHASE / 208 – 230V OUTDOOR UNIT MODEL : MLC040/ 050C (COOLING ONLY) 50HZ / 3 PHASE / 380 – 415V, 60HZ / 3 PHASE / 200 – 230V Page 58
OUTDOOR UNIT MODEL : MLC020/ 025BR (HEAT PUMP) 50HZ / 1 PHASE / 220 – 240V OUTDOOR UNIT MODEL : MLC030CR (HEAT PUMP) 50HZ / 1 PHASE / 220 – 240V, 60 HZ / 1 PHASE / 220V OUTDOOR UNIT MODEL : MLC040/ 050CR (HEAT PUMP) 50HZ / 3 PHASE / 380 – 415V, 60HZ / 3 PHASE / 220V Page 59
LOW AMBIENT UNIT (OPTIONAL) OUTDOOR UNIT MODEL : MLC010B / 015B (50HZ) OUTDOOR UNIT MODEL : MLC020B / 025B (50HZ) Page 60
LOW AMBIENT UNIT OUTDOOR UNIT MODEL : MLC010/ 015BR 50HZ / 1 PHASE / 220 – 240V OUTDOOR UNIT MODEL : MLC020BR 50HZ / 1 PHASE / 220 – 240V OUTDOOR UNIT MODEL : MLC025BR 50HZ / 1 PHASE / 220 – 240V Page 61
SINGLE PHASE FOR 4HP OUDOOT UNIT MODEL : MLC/ M4LC040C (COOLING ONLY) MODEL : MLC/ M4LC040CR (HEATPUMP) Page 62
Special Precautions for R407 Special Precautions When Dealing With Refrigerant R407C Unit 1) What is new refrigerant R407C? R407C is a zeotropic refrigerant mixture which has Zero Ozone Depletion Potential (ODP = 0) and thus conformed to the Montreal Protocol regulation. It requires Polyol-ester oil (POE) oil for its compressor's lubricant. Its refrigerant capacity and performance are about the same as the refrigerant R22.
c) Ensure that the compressor is not expose to open air for more than the recommended time specified by its manufacturer (typically less than 10 minutes). Removed the seal-plugs only when the compressor is about to be brazed. d) The system should be thoroughly vacuumed to 1.0 Pa (-700mmHg) or lower. This vacuuming level is more stringent than R22 system so as to ensure no incompressible gas and moisture in the system.
Installation Cautio Caution Sharp edges and coil surfaces are potential injury hazard. Avoid from contact with them. (1) Installation of Outdoor Unit Preliminary Site Survey • Electrical supply and installation is to conform to local authority's (e.g. National Electrical Board) codes and regulations. • Voltage supply fluctuation must not exceed ± 10% of rated voltage. Electricity supply lines must be independent of welding transformer which can cause high supply fluctuations.
MCM-D MCM061C Figure B Please ensure that the following steps are taken : • Check the gradient for drainage flow as recommended in Figure B. • Provide clearance for easy servicing and optimal air flow as shown in Figure C. • The indoor unit must be installed such that there is no short circuit of the cool discharge air with the warm return air. • Do not install the indoor unit where there is direct sunlight shining on the unit. The location should be suitable for piping and drainage installation.
MCM061/ 062C Figure C • Provide the installation space as shown in Figure D.
Installation - Ceiling Exposed Type STEP 1 Remove air intake grille, side panel, side close-up and hanger bracket from the unit; see Fig E. SIDE CLOSE UP HANGER BRACKET SIDE FRAME AIR INTAKE GRILLE Figure E STEP 2 Position the hanger rods as per Fig B and install the hanger bracket; see Fig F. Figure F STEP 3 Hanger up the unit and tighten the bolt, after completed the piping and drain pipe; install back the grille and panel Fig. G.
Installation - Floor Standing Type (OPTIONAL SPECIFICATION) STEP 1 Remove air intake grille, side panel, side close-up and side panel from the unit; see Fig E. STEP 2 Position the floor support (field supply) as per Fig B. install the unit; see Fig I. Wall Wall Fig I STEP 3 Two types of piping and drain pipe connection as Fig J.
(2) Installation of Outdoor Unit As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected for outdoor unit should fulfill the following requirements: • Install the condensing (outdoor) unit in away such that hot air distributed by the outdoor condensing unit cannot be drawn in again (as in the case of short circuit of hot discharge air). Allow sufficient space for maintenance around the unit.
(3) Refrigerant Piping Maximum Pipe Length And Maximum Number Of Bends • When the pipe length becomes too long, both the capacity and reliability drop. As the number of bends increases, system piping resistance to the refrigerant flow increases, thus lowering the cooling capacity, and as the result the font compressor may become defective. Always choose the shortest path and follow the recommendation as tabulated below: MODEL DATA Max. Length, L Max. Elevation, H Max. No.
(5) Vacuuming and charging • The precharged outdoor unit does not need any vacuuming or charging. However once it is connected, the connecting pipe line and the indoor need to be vacuumed before releasing the R22/R407C from the outdoor unit. 1) Open the service port core cap. 2) Connect pressure gauge to the service port. 3) Connect the line to vacuum pump. Open the charging manifold valve and turn the pump on. Vacuum to –0.1 MPa (-760mmHg) or lower.
(6) Additional Charge • The refrigerant gas has already charged into the outdoor unit. For the piping length of 5m. Additional refrigerant charge after vacuuming is not necessary. • When the piping length is more than 5m, please use the table below (unit in gram).
(8) Standard Operating Condition Cooling Only Unit Temperature minimum indoor temperature maximum indoor temperature minimum outdoor temperature maximum- outdoor temperature Ts °C 19.4 26.7 19.4 46.0 Th °C 13.9 19.4 13.9 24.0 Ts °C 15.0 26.7 -8.0 24 Th °C -9.
(9) Operating State and Fault Table Wireless Remote Control - Handset Cooling: LED Indicator Light Display COOL DRY Heatpump : LED Indicator Light Display FAN COOL DRY FAN HEAT Self Diagnosis Table Operation/ Faulty Indicator COOL DRY FAN HEAT Cooling mode Dry mode Fan mode Heat mode Auto mode in heating operation Auto mode in heating operation Defrost operation Compressor overload protection Outdoor coil sensor contact loose/short Room air sensor contact loose/short ON
Remote Control Operation Guide G6 Remote Controller 8 7 2 SIGNAL TRANSMISSION INDICATION • Blink to confirm the last setting has been send to the unit. FAN SPEED AND VENTILATION MODE SELECTION Press the button until the desired fan speed is achieved. TEMPERATURE SETTING • • 6 OPERATION MODES • Press the “mode” button for select the type of operating mode. • Cooling only unit: Cool →Dry →Fan. • Heatpump unit : • Set the desire room temperature. Press button to increase or decrease the set temperature.
8 10 9 4 SENSOR ON/OFF AUTO 2 TEMP HIGH MED TIMER 1 FAN ON/OFF 2 COOL FAN DRY HEAT 3 MODE TEMP 7 FAN LOW 5 4 1 SWING SLEEP 6 SWING SLEEP TIMER MODE 6 3 5 7 SLM AC-5300 (OPTIONAL) 1. “ON/OFF” switch • Press to start the air conditioner unit. • Press again to stop the unit. 2. Temperature setting • Set the desired room temperature. • Press button to increase or decrease the set temperature. Setting range are between 16oC to 30oC (60oF to 80oF). 3.
G8 Remote Controller 1 2 4 6 5 12 3 8 7 9 10 11 1. Transmission source • The source where the signal will be transmitted. 2. Signal Transmission indication • Blink to confirm the last setting has been send to the unit. 3. On/Off Button • Press once to start the air conditioner. • Press again to stop the unit. 4. Temperature setting • To set the desired room temperature, press the button to increase or decrease the set temperature.
Trouble Shooting When any air-conditioner malfunction is noted, immediately switch off the power supply to the unit, and contact the local dealer, if necessary. Some simple troubleshooting tips are given below : FAULT CAUSE 1. Fan does not work 3 minutes after starting • Protection against the frequent starting. Wait 3 or 4 minutes. 2. The air conditioning unit does not work • Power failure or you must be replaced the fuse. • The power plug is disconnected.
The design of the MLC outdoor series allows servicing to be carried out readily and easily. The removal of the top side, front and back panel make almost every part accessible. Under normal circumstances, these outdoor units only require a check and cleaning of air intake coil surface once quarterly.
Trouble Shooting When any air-conditioner malfunction is noted, immediately switch off the power supply to the unit, and contact the local dealer, if necessary. Some simple troubleshooting tips are given below : FAULT CAUSE 1. Fan does not work 3 minutes after starting • Protection against the frequent starting. Wait 3 or 4 minutes. 2. The air conditioning unit does not work • Power failure or you must be replaced the fuse. • The power plug is disconnected.
For Cooling Only Models Or Heat Pump Models (Cooling Cycle) Diagnosis By Flow Chart The following chart are efficient checking procedures for troubleshooting when these fan-coil units are coupled with the condensing units using standard wiring. For dual circuited models, perform the procedures for each circuit.
Insufficient Cooling Insufficient Cooling Compressor Cycling Cycling On Dual Pressure Switch Tripping High Discharge Pressure or Low Suction Pressure Clogged Capillary or Pressure Switch Switch Faulty Running Overcurrent Relay For Compressor Tripping High Voltage or Low Voltage Single-Phase High Discharge Pressure And High Suction Pressure Loose Connections Discharge Gas Thermostat or Internal Thermostat Tripping High Discharge Pressure And Low Suction Pressure Refrigerant Short Charge or Refrig
High Suction Pressure High Suction Pressure Low Evaporator Air Inlet Temp. Excessive Fresh Air Intake Reduce The Fresh Air Intake Insufficient Duct Insulation Reinforce The Duct Insulation Defective Compressor Valve Change Or Repair The Compressor Overcharged Refrigerant Purge The Refrigerant Low Suction Pressure Low Suction Pressure Clogged Air Filter Evaporator Air Flow Restricted Evaporator Air Inlet Temp.
For Heat Pump Models By means of pressure readings : Too High PROBABLE CAUSE A Little High Circuit Normal Too Low Data A Little Low PRESSURE High Side Low Side 1. Overcharged with refrigerant. 2. Non-condensable gases in refrigerant circuit (e.g. oil). 3. Obstructed air-intake/discharge. 4. Short circuiting of hot air at outdoor unit. 1. Poor compression/no compression (compressor defective.) 2. Check valve stick in open position. 3. Reversing valve leaking. 1. Undercharged with refrigerant. 2.
The most common causes of air conditioner failure to “start" are: a) Voltage not within ±10% of rated voltage. b) Power supply interrupted. c) Control settings improper. d) Air conditioner is disconnected from main power source. e) Fuse blown or circuit breaker off. ii) Diagnosis of Refrigerant Circuit / Application There might be some cases where the unit starts running but does not perform satisfactory, i.e. insufficient cooling.
Parts List Model : MCM020/ 025 D/DR NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PARTS DESCRIPTION TOP PANEL HANGER BRACKET - LEFT CONTROL BOX CLOSE UP, SIDE PANEL SIDE FRAME ASSY - LEFT COIL HOLDER ASSY - LEFT FAN DECK AIR INTAKE GRILLE ASSY FRONT FRAME – LEFT LOUVER ASSY FRONT FRAME – RIGHT AIR SWIND MOTOR ASSY BOTTOM PANEL DRAIN PAN ASSY CENTRE SUPPORT BRACKET NO.
Model : MCM030 D/DR NO. PART DESCRIPTION NO.
Model : MCM040/ 050 D/DR NO. PART DESCRIPTION NO.
Model : MCM061 / 062 C/CR NO. PART DESCRIPTION NO.
Model : MLC/ M4LC020/ 025 B/BR MLC030 B/BR NO PART DESCRIPTION NO.
Model : MLC/ M4LC030/ 040/ 050/ 061 C/CR, M4LC060C MLC035 C/CR NO PART DESCRIPTION NO.
REGISTERED ISO 9002 ©2004 McQuay International +1 (800) 432-1342 www.mcquay.