Installation guide
25
4-INSTALLATION AND ASSEMBLY
Technical Dept. - All rights reserved - Reproduction is prohibited
ELECTRICAL CONNECTION
First connect the power cable to the rear part of the product and then to a wall socket, which must always be accessible.
Should this not be possible, during installation, insert appropriate power supply disconnection devices, in compliance with the national
regulations regarding electrical installations.
It is recommended to disconnect the power cable when the product is not used.
SETTING UP THE CLADDING
The product must be fully tested before the cladding is applied. The company cannot be held liable for any damage to the
cladding should operating anomalies arise, which were not veried before the cladding was applied to the product.
IT IS MANDATORY to check the tightness of all the pipes through which smoke passes (smoke tting, gaskets and ue coupling)
before setting up the cladding.
READ THE "OPERATION TEST" CHAPTER BEFORE STARTING ANY PRODUCT CLADDING OPERATION.
The product and the cladding parts must be fastened together WITHOUT COMING INTO CONTACT WITH THE STEEL STRUCTURE in
order to prevent heat from being transmitted to the marble and/or stone and to allow for normal thermal expansion. Pay attention to the
wood nishes, such as beams or shelves.
It is recommended to set up the counter hood made of 15 to 20 mm thick reproof plasterboard with a freestanding frame made of a
galvanised prole to prevent bearing the weight on the cladding components (wooden beams or marble lintels), which do not have a
freestanding structure and in order to intervene easily in case of anomalies and/or future maintenance. Dry mount the hearth
of the cladding, leaving a 1 cm gap between the insert and the hearth for insulation.