Operating instructions

PELLET STOVES Chapter 4
INSTALLATION AND USE MANUAL
page 52
Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
4.12.2. Other signals on the display
The following table summarizes that messages that may be shown on the dispaly panel
MESSAGE ON DISPLAY MEANING
off The stove is off
fan acc Initial lighting sequence
load wood Pellet loading
fire on Lighting sequence and adjsutment/stabilizing of flame
Eco Stop The stove automatically shuts down upon reaching the temperature
20 C° Example of room temperature
62 C° Example of water temperature
UT 01, UT02,… user paramters for programming time, time periods, etc.
day1,,,7 Days of the week
set Setting of stove operating mode (e.g. SET MAN = Stove set to manual)
Alar fan fail The smoke fan is not operating correctly
stop fire Automatic cleaning of the brazier in the set period of time
mcz spa mcz spa
cool fire The stove is in cooling mode
alar dep fail The pressure switch has tripped, indicating difficulty in smoke expulsion
alarm smoke probe The smoke probe is not working correctly
alar no acc An ignition attempt has failed.
alar no fire There is no fire stove
alar fail sic Thermal alarm Excessive heat in the structure
4.12.3. Lockout of the stove
The following things can cause the stove to lock out:
Overheating of the structure and of the pellet hopper
Overheating of the water in the boiler (T>85°C)
High pressure in the outlet fumes (as read by the pressure
switch) and therefore possible obstruction of the smoke
discharge system or external back-pressure.
Pressure in system less than or greater than the minimum or
maximum parameters of operation
The lockout is indicated by the LED (7) lighting up, accompanied by a
beep.
In this situation the shutdown cycle is automatically activated.
Once this process has started, any attempt to reset the system is
useless. The cause of the lockout is shown on the display (8).
4.12.3.1.
Boiler bulb thermostat
The stove goes into a safety ALARM state called “ALAR SIC FAIL” due
to the water temperature being too high.
MANUAL RESET THERMOSTAT
With the stove cold
, in order to carry out the manual reset, you
must unscrew the cap of the thermostatic probe on the back and
press the red button to reset. You will hear a "click" of the
thermostat. Then put the protection cap back in place.
Figure 7 and
8.
Figure 7 - Touche de réarmement de la sonde à
boule
Figure 8 - Comment réarmer le thermostat à
boule une fois que le poêle est froid.