2-INSTALLATION
EXAMPLES OF CORRECT INSTALLATION
1. Installation of Ø120mm ue with hole for the passage
of the pipe increased by:
minimum 100mm around the pipe if next to non
ammable parts such as cement, brick, etc.; or
minimum 300mm around the pipe (or as required by
rating plate) if next to ammable parts such as wood etc.
In both cases, install suitable insulation between the ue
and the ceiling.
Always check and respect the data tags on the ue,
in particular the minimum safety distances from
combustible materials.
The previous rules also apply for holes made in walls.
2. Old ue, minimum pipe Ø100mm with the inclusion of
an external access door for chimney cleaning.
3. External ue made of insulated stainless steel pipes,
i.e. with double walls minimum Ø100mm: all securely
mounted on the wall. With wind-proof chimney pot. See
g. 7 type A.
4. Ducting system using T ttings that allow easy access
for cleaning without having to remove the pipes
FIGURE 11
U = INSULATING
V = ANY REDUCTION FROM 100 TO 80 MM
I = INSPECTION CAP
S = INSPECTION ACCESS PANEL
P = AIR INLET
T = T JOINT WITH INSPECTION CAP
A = MINIMUM 40 MM
B = MAXIMUM 4 M
C = MINIMUM
D = MINIMUM 400 MM
E = HOLE DIAMETER
F = SEE FIG.2-3-4-5-6