FILLING OF THE FLUID RESERVOIR
WARNING
Use only MDG Neutral Fog Fluid. Not doing so, will void the warranty
and may damage the generator.
CAUTION
DISCONNECT UNIT BEFORE ADDING FOG FLUID AND WAIT COUPLE OF
MINUTES TO BE SURE THE RESERVOIR IS FULLY DEPRESSURIZED.
Unscrew the brass closure and pour the MDG Neutral Fog Fluid until it reaches the
inside bottom of the opening.
Avoid overfilling. Screw back the closure and make sure it is tightened.
GAS REQUIREMENTS
WARNING
In the European Community the gas cylinder and regulator must be
compliant with the Pressure Vessel Directive.
In North America the gas cylinder must be manufactured, inspected and
tested in accordance with U.S. Department of Transportation (DOT) 3AL
and Transport Canada (TC) 3ALM requirements.
WARNING
The CO
2
gas regulator and the N
2
regulator do not use the same thread to
mate with the cylinder. Make sure to use a CO
2
gas regulator with the CO
2
gas cylinder and to use a N
2
gas regulator with the N
2
cylinder.
WARNING
Only use industrial grade Carbon Dioxide gas (CO
2
) or
industrial grade Nitrogen gas (N
2
).
CAUTION
To prevent gas leak and drop of pressure, ALWAYS use a neoprene washer
when connecting the regulator to the cylinder