User manual

4 / 9
WARNING:
When not in use ALWAYS switch off the power switch located on the back
panel, or unplug the Fogger.
Never install above people.
This Fogger must be installed in an upright position on a stable and
leveled surface.
Do not operate at less than 2 meters (6.5 ft.) from people.
Use in a well ventilated area.
TECHNICAL SPECIFICATIONS
Electrical power requirements:
Mega Max: Model MM20 version-208V, 1Ø, 50/60Hz, 2815 W.
version-230V, 1Ø, 50/60Hz, 2815 W.
Mini Max: Model MM15 version-115V, 50/60Hz, 1415 W.
version-230V, 1Ø, 50/60Hz, 1415 W.
The AC power cable for the Mega Max
TM
/ Mini Max
TM
Fogger is connected as
follow:
BROWN or BLACK wire is the LINE 1
BLUE or WHITE wire is the LINE 2 for 208 and 230
or (NEUTRAL for 115VAC)
GREEN YELLOW or GREEN wire GROUND
Connect power cable according to valid electrical standards.
OUTPUT & CONSUMPTION
Mega Max: Model MM20
Variable output up to 140 m
3
(5000 ft
3
) of fog @ full volume
Consumption: 3,5 L (53 oz) per hour
Mini Max: Model MM15
Variable output up to 56 m
3
(2000 ft
3
) of fog @ full volume
Consumption: 1,5 L (53 oz) per hour