6.0 DIAGNOSTICS AND CONTROL
Configuration, control and diagnostics of the master station is per-
formed by connecting a Windows PC running a terminal program or
other MDS diagnostics software to a diagnostic port on the rear of the
unit (Figure 26). (If a PC is not available, many of the same functions
may be performed using the front panel interface, described in
Section 6.4, Conguration and Programming using the Front Panel,
beginning on Page 56.)
Figure 26. PC Connected to the Master Station
This section explains how to connect a PC to the master station, and
describes the commands that can be used for programming and diagnos-
tics.
6.1 PC Connection
1. Set Jumper J15 (on the vertical Interface Board) to “PC.” This
removes 14 V from Pin 6 of the
DIAGNOSTIC PORT
.
TO DB-9
DIAGNOSTICS
CONNECTOR (J1)
TO COMPUTER'S
RS-232 CONNECTOR
COMPUTER
RUNNING INSITE
SOFTWARE
J15
ENSURE JUMPER J15
(INSIDE RADIO) IS SET
TO "PC"
(On Vertical Interface Board)