Specifications
44 MDS 4790/9790 Series I/O Guide MDS 05-3438A01, Rev. E
Key Radio
Transmitter
KEY
This command activates the transmitter. See also the DKEY command.
Operation Log LOG [CLR]
This command displays or clears a list of the last 800 operating changes,
called “system events.” These events include alarm notifications, as
well as normal operator actions such as turning the power on or off. In
many cases, the events leading up to a failure can be reviewed to help
determine the cause of a problem.
Entering the
LOG command without any parameters displays the entire
event history. Entering
LOG CLR or LOG CLEAR clears all current events
from the log history.
Multiple-Drop
Address
MADDR [NONE, 1–255]
The radio’s Multi-Drop Address uniquely identifies this radio on an
RS-232 COS (code-operated switch) bus connected to the rear panel’s
DIAGNOSTIC PORT, J1. The unit’s address initially is set as NONE, for a
computer directly connected to the
DIAGNOSTIC PORT of one radio.
MADDR addresses can range from 1...255. The master station will ignore
diagnostic messages sent to other Multi-Drop Addresses. With the
MADDR address programmed, MDS’ InSite™ network management
system program can poll master stations through the COS bus to receive
diagnostic information of the master unit itself. The
MADDR command
will work on MDS x790 master stations with software version 1.7 or
later installed. For more details, please see “Connecting Multiple Mas-
ters at One Site” on Page 30.
Soft-Carrier Dekey (SCD) 0 msec
Timeout-Timer 30 seconds (ON)
TX Level Auto
Unit Diagnostic Service (DTYPE) Node
Table 11. Defaults for User-Configurable Parameters (Continued)
Function Value
Manual Key screen, Page 68
A
B
Event Log screen, Page 75
Clear Logs screen, Page 75
A
B
Multi-Drop Address (MADDR)
screen, Page 68
A
B