Specifications
MDS 05-3438A01, Rev. E MDS 4790/9790 Series I/O Guide 81
4. Use the DLINK ON and DLINK [baud rate] commands to enable net-
work-wide diagnostics and set the baud rate at the diagnostics port
of each node radio.
5. Connect same-site radios using a null-modem cable at the radios’
diagnostic ports.
6. Connect a PC on which MDS InSite software is installed to the root
radio, or to one of the nodes, at the radio’s diagnostic port. (This PC
may be the PC being used to collect payload data, as shown in
Figure 36.) To connect a PC to the radio’s
DIAGNOSTICS port, an
RJ-11 to DB-9 adapter (MDS P/N 03-3246A01) is required. If
desired, an adapter cable may be constructed from scratch using the
information shown in Figure 37.
7. Launch the MDS InSite software at the PC. (See the InSite Radio
System Management Software User’s Guide for instructions.)
Invisible place holder
Figure 36. Network-Wide Remote Diagnostics Setup
RTU
RTU
TO
DIAGNOSTICS
PORT
TO DATA
PORT
MASTER STATION
ROOT
DTYPE
ROOT
DIAGNOSTICS DATA
(TO InSite)
HOST COMPUTER
PAYLOAD DATA
RTU
(TO SCADA APPLICATION)
DTYPE
NODE
DTYPE
NODE
DTYPE
NODE