Specifications

MDS 05-2873A01, Rev. E iNET Series Installation & Start-Up 19
SPECIFICATIONS
GENERAL
Temperature Range: –30° C to +60° C (–22° F to 140° F)
Humidity: 95% at +40° C (104° F); non-condensing
Primary Power: 10.5–30 Vdc (13.8 Vdc, Nominal)
External Power Supply Options: 48 Vdc; 110–120/210–220 Vac
Supply Current (typical): (@ 1 Watt RF Output)
Transmit: 8 Watts (580 mA @ 13.8 Vdc)
Receive: 2.8 Watts (203 mA @ 13.8 Vdc)
Size (Excluding mtg. hardware): 1.5" x 6" x 4" (H x W x D)
3.8 x 15.2 x 10.2 cm
Weight: 0.9 kg / 2 lb
Case: Cast Aluminum
RADIO CHARACTERISTICS
GENERAL:
Frequency Range: 902–928 MHz Industrial, Scientific &
Medical (ISM) Band
Mode: Freq. Hopping Spread-Spectrum (FHSS)
Boot Time: 30 sec
Time Required to Associate
with Access Point: 20 sec
TRANSMITTER:
Power Output
(at antenna connector): 0.1 to 1.0 watt (+20 dBm to +30 dBm)
Increments of 1.0 dB, set by user
Duty Cycle: Continuous
Output Impedance: 50 Ohms
RECEIVER:
Type: Double conversion superheterodyne
Sensitivity (< 1x10
-
6
BER): iNET: –92 dBm @ 512 kbps
iNET: –99 dBm @ 256 kbps
iNET-II: -92 dBm @ 1 Mbps
iNET-II: -97 dBm @ 512 kbps