Product specifications
Table Of Contents
- 1.0 ABOUT THIS MANUAL
- 2.0 PRODUCT DESCRIPTION
- 2.1 Transceiver Features
- 2.2 Model Number Codes
- 2.3 Spread Spectrum Radios— How Are They Different?
- 2.4 Typical Applications
- Multiple Address Systems (MAS)
- Point-to-Point System
- Adding a Tail-End Link to an Existing Network
- Extending a TransNET Network with a Repeater
- 2.5 Accessories
- 3.0 INSTALLATION PLANNING
- 3.1 General Requirements
- 3.2 Site Selection
- Terrain and Signal Strength
- Conducting a Site Survey
- 3.3 A Word About Radio Interference
- 3.4 Antenna & Feedline Selection
- Antennas
- Feedlines
- Antenna System Ground
- 3.5 How Much Output Power Can be Used?
- 4.0 INSTALLATION
- 4.1 Transceiver Installation
- 4.2 Configuring Multiple Remote Units
- 4.3 Tail-End Links
- 4.4 Configuring a Network for Extensions
- 5.0 OPERATION
- 5.1 Initial Start-up
- 5.2 Performance Optimization
- Antenna Aiming
- Antenna SWR Check
- Data Buffer Setting—Modbus Protocol
- Hoptime Setting
- TotalFlow™ Protocol at 9600 with Sleep Mode
- Operation at 115200 bps
- Baud Rate Setting
- Radio Interference Checks
- 6.0 RADIO PROGRAMMING
- 6.1 Radio Programming Methods
- Terminal Interface
- PC-Based Configuration Tool
- 6.2 User Commands
- Entering Commands
- 6.3 Detailed Command Descriptions
- ADDR [1–65000]
- AMASK [0000 0000–FFFF FFFF]
- AT [ON, OFF]
- ASENSE [HI/LO]
- BAUD [xxxxx abc]
- BAND [A, B, C]
- BUFF [ON, OFF]
- CODE [NONE, 1…255]
- CSADDR [1–65000, NONE]
- CTS [0–255]
- CTSHOLD [0–60000]
- DEVICE [DCE, CTS KEY]
- DLINK [xxxxx/ON/OFF]
- DKEY
- DTYPE [NODE/ROOT]
- FEC [ON, OFF]
- HOPTIME [7, 28]
- INIT
- HREV
- KEY
- LED [ON, OFF]
- LPM [1, 0]
- LPMHOLD [0–1000]
- MODE [M, R, X]
- MRSSI [NONE, –40...–90]
- OT [ON, OFF]
- OWM [xxxxx]
- OWN [xxxxx]
- PORT [RS232, RS485]
- PWR [20–30]
- REPEAT [0–10]
- RETRY [0–10]
- RSSI
- RTU [ON, OFF, 0-80]
- RX [xxxx]
- RXD [0–255]
- RXTOT [NONE, 0–1440]
- SAF [ON, OFF]
- SETUP
- SER
- SHOW CON
- SHOW PWR
- SHOW SYNC
- SKIP [NONE, 1...8]
- SLEEP [ON, OFF]
- SREV
- STAT
- TEMP
- TX [xxxx]
- UNIT [10000–65000]
- XADDR [0–31]
- XMAP [00000000-FFFFFFFF]
- XPRI [0–31]
- XRSSI [NONE, –40...–120]
- ZONE CLEAR
- ZONE DATA
- 7.0 TROUBLESHOOTING
- 7.1 LED Indicators
- 7.2 Alarm Codes
- Checking for Alarms—STAT command
- Major Alarms versus Minor Alarms
- Alarm Code Definitions
- 7.3 Troubleshooting Chart
- 7.4 Performing Network-Wide Remote Diagnostics
- 7.5 Internal Fuse Replacement
- 8.0 RADIO FIRMWARE UPGRADES
- 8.1 Obtaining New Firmware
- Saving a Web-Site Firmware File Onto Your PC
- 8.2 Installing Firmware Into Your Radio
- 9.0 OPERATING PRINCIPLES AND CONFIGURATION
- 9.1 SAF Operation with Extension Radios
- Simple Extended SAF Network
- Extended SAF Network
- Retransmission and ARQ Operation
- SAF Configuration Example
- 9.2 Synchronizing Network Units
- Synchronization Messages
- 9.3 Using AT Commands
- 9.4 Configuration Parameters for Store-and-Forward Services
- 9.5 Using the Radio’s Sleep Mode (Remote Units Only)
- Sleep Mode Example
- 9.6 Low-Power Mode (LPM)—Master Enabled
- Setup Commands
- Reading RSSI and Other Parameters with LPM Enabled
- Power Consumption Influence by HOPTIME and SAF Settings
- 9.7 Low-Power Mode versus Remote’s Sleep Mode
- 9.8 Mobile Operation Support
- Introduction
- Operational Influences—Hoptime & SAF
- 9.9 MIRRORED BITS™ Protocol Support
- 9.10 Seamless Mode Emulation
- Master Station Configuration
- Antenna System for Co-Located Master Stations
- 10.0 TECHNICAL REFERENCE
- Pin Descriptions—RS/EIA-232 Mode
- Pin Descriptions—RS/EIA-422/485 Mode
- Using the I/O Points with InSite™ NMS Software
- Application Example—Digital Input and Output at a Remote

MDS 05-2708A01, Rev. E MDS TransNET Ref. Manual 29
ADDR [1–65000]
Network Address
This command sets or displays the radio’s network address. The network
address can range from 1 to 65000.
A network address must be programmed at the time of installation and must
be common across each radio in a given network. Radios are typically
shipped with the network address unprogrammed, causing the address to
display as
NONE. If the address is not set (or is set to a wrong value) it leaves
the system in an invalid state, preventing operation and generating an alarm.
NOTE: It is recommended that the last four digits of the Master radio’s serial number be
used for the network address. This helps avoid conflicts with other users.
AMASK [0000 0000–FFFF FFFF]
Alarm Mask
This command sets the alarm bits that cause the alarm output signal to be trig-
gered. The
PWR LED will still flash for all alarms, but the alarm output signal
will only be activated for those alarms that have the corresponding mask bit
set. The hex value for the mask aligns directly with the hex value for the
ALARM command. The default is FFFF FFFF. Through proper use of the
AMASK command, it is possible to tailor the alarm response of the radio.
Refer to the Using the AMASK Command Application Bulletin (AP_08004)
for more information on configuring the alarm mask.
AT [ON, OFF]
Hayes-Compatible AT Command Support
AT-style modem commands, also know as “Hayes-Compatible Commands”,
can be processed through the payload port. By setting
AT ON at the Master
(
MODE M), individual Remotes can be accessed by using ATDT
[Unit Address]. In this mode, RTUs designed only for dial-up access can be
accessed through the Master station. For more details, see See “Using AT
Commands” on Page 55 and “OT [ON, OFF]” on Page 37.
ASENSE [HI/LO]
Alarm Output Sense
This command is used to set the sense of the alarm output at Pin 6 of the DATA
connector. The default is
HI which means an alarm is present when an RS-232
high is on Pin 6.
BAUD [xxxxx abc]
Data Interface Port Baud Rate
This command sets or displays the communication attributes for the normal
payload communications through the
DATA port. The command has no effect
on the RJ-11
DIAG(NOSTICS) port.