Product specifications
Table Of Contents
- 1.0 ABOUT THIS MANUAL
- 2.0 PRODUCT DESCRIPTION
- 2.1 Transceiver Features
- 2.2 Model Number Codes
- 2.3 Spread Spectrum Radios— How Are They Different?
- 2.4 Typical Applications
- Multiple Address Systems (MAS)
- Point-to-Point System
- Adding a Tail-End Link to an Existing Network
- Extending a TransNET Network with a Repeater
- 2.5 Accessories
- 3.0 INSTALLATION PLANNING
- 3.1 General Requirements
- 3.2 Site Selection
- Terrain and Signal Strength
- Conducting a Site Survey
- 3.3 A Word About Radio Interference
- 3.4 Antenna & Feedline Selection
- Antennas
- Feedlines
- Antenna System Ground
- 3.5 How Much Output Power Can be Used?
- 4.0 INSTALLATION
- 4.1 Transceiver Installation
- 4.2 Configuring Multiple Remote Units
- 4.3 Tail-End Links
- 4.4 Configuring a Network for Extensions
- 5.0 OPERATION
- 5.1 Initial Start-up
- 5.2 Performance Optimization
- Antenna Aiming
- Antenna SWR Check
- Data Buffer Setting—Modbus Protocol
- Hoptime Setting
- TotalFlow™ Protocol at 9600 with Sleep Mode
- Operation at 115200 bps
- Baud Rate Setting
- Radio Interference Checks
- 6.0 RADIO PROGRAMMING
- 6.1 Radio Programming Methods
- Terminal Interface
- PC-Based Configuration Tool
- 6.2 User Commands
- Entering Commands
- 6.3 Detailed Command Descriptions
- ADDR [1–65000]
- AMASK [0000 0000–FFFF FFFF]
- AT [ON, OFF]
- ASENSE [HI/LO]
- BAUD [xxxxx abc]
- BAND [A, B, C]
- BUFF [ON, OFF]
- CODE [NONE, 1…255]
- CSADDR [1–65000, NONE]
- CTS [0–255]
- CTSHOLD [0–60000]
- DEVICE [DCE, CTS KEY]
- DLINK [xxxxx/ON/OFF]
- DKEY
- DTYPE [NODE/ROOT]
- FEC [ON, OFF]
- HOPTIME [7, 28]
- INIT
- HREV
- KEY
- LED [ON, OFF]
- LPM [1, 0]
- LPMHOLD [0–1000]
- MODE [M, R, X]
- MRSSI [NONE, –40...–90]
- OT [ON, OFF]
- OWM [xxxxx]
- OWN [xxxxx]
- PORT [RS232, RS485]
- PWR [20–30]
- REPEAT [0–10]
- RETRY [0–10]
- RSSI
- RTU [ON, OFF, 0-80]
- RX [xxxx]
- RXD [0–255]
- RXTOT [NONE, 0–1440]
- SAF [ON, OFF]
- SETUP
- SER
- SHOW CON
- SHOW PWR
- SHOW SYNC
- SKIP [NONE, 1...8]
- SLEEP [ON, OFF]
- SREV
- STAT
- TEMP
- TX [xxxx]
- UNIT [10000–65000]
- XADDR [0–31]
- XMAP [00000000-FFFFFFFF]
- XPRI [0–31]
- XRSSI [NONE, –40...–120]
- ZONE CLEAR
- ZONE DATA
- 7.0 TROUBLESHOOTING
- 7.1 LED Indicators
- 7.2 Alarm Codes
- Checking for Alarms—STAT command
- Major Alarms versus Minor Alarms
- Alarm Code Definitions
- 7.3 Troubleshooting Chart
- 7.4 Performing Network-Wide Remote Diagnostics
- 7.5 Internal Fuse Replacement
- 8.0 RADIO FIRMWARE UPGRADES
- 8.1 Obtaining New Firmware
- Saving a Web-Site Firmware File Onto Your PC
- 8.2 Installing Firmware Into Your Radio
- 9.0 OPERATING PRINCIPLES AND CONFIGURATION
- 9.1 SAF Operation with Extension Radios
- Simple Extended SAF Network
- Extended SAF Network
- Retransmission and ARQ Operation
- SAF Configuration Example
- 9.2 Synchronizing Network Units
- Synchronization Messages
- 9.3 Using AT Commands
- 9.4 Configuration Parameters for Store-and-Forward Services
- 9.5 Using the Radio’s Sleep Mode (Remote Units Only)
- Sleep Mode Example
- 9.6 Low-Power Mode (LPM)—Master Enabled
- Setup Commands
- Reading RSSI and Other Parameters with LPM Enabled
- Power Consumption Influence by HOPTIME and SAF Settings
- 9.7 Low-Power Mode versus Remote’s Sleep Mode
- 9.8 Mobile Operation Support
- Introduction
- Operational Influences—Hoptime & SAF
- 9.9 MIRRORED BITS™ Protocol Support
- 9.10 Seamless Mode Emulation
- Master Station Configuration
- Antenna System for Co-Located Master Stations
- 10.0 TECHNICAL REFERENCE
- Pin Descriptions—RS/EIA-232 Mode
- Pin Descriptions—RS/EIA-422/485 Mode
- Using the I/O Points with InSite™ NMS Software
- Application Example—Digital Input and Output at a Remote

MDS 05-2708A01, Rev. E MDS TransNET Ref. Manual i
INDEX
A
Accessories (table) 5
ADDR command (set/display radio network address) 29
Alarm
checking for 46
code definitions 47
codes 46
codes, table 47
major vs. minor 46
receiver timeout (RXTOT command) 40
reset output signal 29
set/display output sense (ASENSE command) 29
status (STAT command) 43
ALARM command (superseded; see STAT command) 43
Alarm Mask (AMASK) Command 29
Alarm Sense (ASENSE) Command 29
Alarm Status Command (STAT) 43
AMASK command (configure alarm output signal) 29
Antenna
installation 15
performance optimization 20
selection 9
SWR check 21
system gain vs. power output setting, table 13
Yagi, illustrated 10
ASENSE command (set/display alarm output sense) 29
B
BAUD command (set/display data interface port attributes) 29
Baud rate
setting 22
setting for RJ-11 DIAG port (DLINK command) 49
BUFF command (set/display received data handling mode) 30
C
Cable
data equipment to DATA INTERFACE connector 15, 22
data interface wiring for tail-end links 19
feedlines 10
maximum length, recommended 16, 71
Clear Zone Statisics Log, ZONE CLEAR 44
Clear-to-Send Delay (CTS) Command 31
Clear-to-Send Hold Time (CTSHOLD) Command 32
Clock-Synchronizing Master Address (CSADDR) Command 31
CODE command (display/set encryption value) 31
Command 36
TEMP (radio’s internal temperature reading) 43
Commands










