Product specifications
Table Of Contents
- 1.0 ABOUT THIS MANUAL
- 2.0 PRODUCT DESCRIPTION
- 2.1 Transceiver Features
- 2.2 Model Number Codes
- 2.3 Spread Spectrum Radios— How Are They Different?
- 2.4 Typical Applications
- Multiple Address Systems (MAS)
- Point-to-Point System
- Adding a Tail-End Link to an Existing Network
- Extending a TransNET Network with a Repeater
- 2.5 Accessories
- 3.0 INSTALLATION PLANNING
- 3.1 General Requirements
- 3.2 Site Selection
- Terrain and Signal Strength
- Conducting a Site Survey
- 3.3 A Word About Radio Interference
- 3.4 Antenna & Feedline Selection
- Antennas
- Feedlines
- Antenna System Ground
- 3.5 How Much Output Power Can be Used?
- 4.0 INSTALLATION
- 4.1 Transceiver Installation
- 4.2 Configuring Multiple Remote Units
- 4.3 Tail-End Links
- 4.4 Configuring a Network for Extensions
- 5.0 OPERATION
- 5.1 Initial Start-up
- 5.2 Performance Optimization
- Antenna Aiming
- Antenna SWR Check
- Data Buffer Setting—Modbus Protocol
- Hoptime Setting
- TotalFlow™ Protocol at 9600 with Sleep Mode
- Operation at 115200 bps
- Baud Rate Setting
- Radio Interference Checks
- 6.0 RADIO PROGRAMMING
- 6.1 Radio Programming Methods
- Terminal Interface
- PC-Based Configuration Tool
- 6.2 User Commands
- Entering Commands
- 6.3 Detailed Command Descriptions
- ADDR [1–65000]
- AMASK [0000 0000–FFFF FFFF]
- AT [ON, OFF]
- ASENSE [HI/LO]
- BAUD [xxxxx abc]
- BAND [A, B, C]
- BUFF [ON, OFF]
- CODE [NONE, 1…255]
- CSADDR [1–65000, NONE]
- CTS [0–255]
- CTSHOLD [0–60000]
- DEVICE [DCE, CTS KEY]
- DLINK [xxxxx/ON/OFF]
- DKEY
- DTYPE [NODE/ROOT]
- FEC [ON, OFF]
- HOPTIME [7, 28]
- INIT
- HREV
- KEY
- LED [ON, OFF]
- LPM [1, 0]
- LPMHOLD [0–1000]
- MODE [M, R, X]
- MRSSI [NONE, –40...–90]
- OT [ON, OFF]
- OWM [xxxxx]
- OWN [xxxxx]
- PORT [RS232, RS485]
- PWR [20–30]
- REPEAT [0–10]
- RETRY [0–10]
- RSSI
- RTU [ON, OFF, 0-80]
- RX [xxxx]
- RXD [0–255]
- RXTOT [NONE, 0–1440]
- SAF [ON, OFF]
- SETUP
- SER
- SHOW CON
- SHOW PWR
- SHOW SYNC
- SKIP [NONE, 1...8]
- SLEEP [ON, OFF]
- SREV
- STAT
- TEMP
- TX [xxxx]
- UNIT [10000–65000]
- XADDR [0–31]
- XMAP [00000000-FFFFFFFF]
- XPRI [0–31]
- XRSSI [NONE, –40...–120]
- ZONE CLEAR
- ZONE DATA
- 7.0 TROUBLESHOOTING
- 7.1 LED Indicators
- 7.2 Alarm Codes
- Checking for Alarms—STAT command
- Major Alarms versus Minor Alarms
- Alarm Code Definitions
- 7.3 Troubleshooting Chart
- 7.4 Performing Network-Wide Remote Diagnostics
- 7.5 Internal Fuse Replacement
- 8.0 RADIO FIRMWARE UPGRADES
- 8.1 Obtaining New Firmware
- Saving a Web-Site Firmware File Onto Your PC
- 8.2 Installing Firmware Into Your Radio
- 9.0 OPERATING PRINCIPLES AND CONFIGURATION
- 9.1 SAF Operation with Extension Radios
- Simple Extended SAF Network
- Extended SAF Network
- Retransmission and ARQ Operation
- SAF Configuration Example
- 9.2 Synchronizing Network Units
- Synchronization Messages
- 9.3 Using AT Commands
- 9.4 Configuration Parameters for Store-and-Forward Services
- 9.5 Using the Radio’s Sleep Mode (Remote Units Only)
- Sleep Mode Example
- 9.6 Low-Power Mode (LPM)—Master Enabled
- Setup Commands
- Reading RSSI and Other Parameters with LPM Enabled
- Power Consumption Influence by HOPTIME and SAF Settings
- 9.7 Low-Power Mode versus Remote’s Sleep Mode
- 9.8 Mobile Operation Support
- Introduction
- Operational Influences—Hoptime & SAF
- 9.9 MIRRORED BITS™ Protocol Support
- 9.10 Seamless Mode Emulation
- Master Station Configuration
- Antenna System for Co-Located Master Stations
- 10.0 TECHNICAL REFERENCE
- Pin Descriptions—RS/EIA-232 Mode
- Pin Descriptions—RS/EIA-422/485 Mode
- Using the I/O Points with InSite™ NMS Software
- Application Example—Digital Input and Output at a Remote

MDS 05-2708A01, Rev. E MDS TransNET Ref. Manual iii
XPRI (display/program primary radio’s extended address) 44
XRSSI (sets minimum signal level for sync. with non-primary extension unit) 44
Connectors
Diagnostic Interface, Connections 69
D
Data Baud Rate (BAUD) Command 29
Data Baud Rate (BUFF) Command 30
Data buffer setting 21, 30
DATA INTERFACE
cable wiring for tail-end links, illustrated 19
connections 69
connector pin descriptions, table 70
Data Port Signalling Standard (PORT) Command 37
Default settings
data interface baud rate 22
factory settings reset by INIT command (table) 34
restoring (INIT command) 34
See also individual command descriptions
DEVICE Command 32
DEVICE command (set/display DCE or CTS Key behavior) 32
Diagnostics
network-wide, performing 49
setup mode (SETUP command) 40
using InSite software for network-wide 49
Diagnostics Link (DLINK) 32
Display
alarm output sense (ASENSE command) 29
alarms (STAT command) 43
CTS hold timer value (CTSHOLD command) 32
CTS line response timer value (CTS command) 31
data interface baud rate (BAUD command) 29
device behavior (DEVICE command) 32
hoptime setting (HOPTIME command) 34
network address (ADDR command) 29
operating status commands 24
owner’s message (OWM command) 37
owner’s name (OWN command) 37
receive test frequency (RX command) 39
received data handling mode (BUFF command) 30
received data timeout value (RXTOT command) 40
received signal strength (RSSI command) 38
RF forward output power (PWR command) 38
RF power output, actual measured (SHOW command) 41
skipped frequency zones (SKIP command) 41
temperature, internal (TEMP command) 43
display/set radio mode as master, remote, or extension (see MODE command) 36
DKEY command (disable transmitter) 21, 40
DKEY, Disable Transmitter, Command 33
DLINK command (set/display baud rate of diagnostics link) 49