User manual
the device will turn on for temperatures higher than the 
one set.
• The "Web Connection" button allows you to activate / 
deactivate the sending of the operating data of the ther-
mostat to the website. Disabling the button will NOT be
possible to control the thermostat via the website (see 
the chapter "The Website”).
• The "Advanced" button allows you to set special param-
eters of the thermostat: the field delta (thermic differen-
tial) allows you to set in tenth of degrees (from 0 to 9) 
the range of activation / deactivation. Example: if we set
value to 0 and the set temperature is 20°C, winter mode 
shutdown will occur at 20.1 ° C and the activation at 
19.9 ° C. If we set the field to 2, the shutdown will be at
20.3°C and the activation at 19.7°C. Sensitivity (High, 
Medium, Low) allows you to set the number of readings
that the thermostat uses to calculate the temperature. 
The thermostat does a temperature reading approxi-
mately every 10 seconds, and displays the value based 
on the average temperature. 
High sensitivity: average of 4 readings. 
Medium sensitivity: average of 8 readings. 
Low sensitivity: average of 16 readings.
The field “Correction” allows you to modify the value 
of the temperature detected by the thermostat, in case is 
not equal to the actual temperature for particular envi-
ronmental conditions, or to calibrate in a more precise 
17