Meaco 10L Basic Small Home Dehumidifier DEHUMIDIFIER OPERATING INSTRUCTIONS All the drawings in this manual may be different with the material objects, please refer to the material objects for reference.
BEFORE FIRST USE Read and follow all the instruction even if you feel you are familiar with the product , and find a place to keep it handy for future reference. For your convenience record the complete model number ( located on the product identification plate ) and the date you received the product , together with your purchase receipt and attach to the warranty and service information. NOTE: The rating of this product ( as marked on the product identification plate ) is based on specific loading tests .
IMPORTANT SAFEGUARDS When using any electrically powered dehumidifier, basic safety precaution should always be followed , including the following: PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THE PRODUCT WARNINNG-to reduce the risk of fire , electrical shock or injury to persons or property : 1. Always operate the product from a power source of the same voltage, frequency and rating as indicated on the product identification plate . 2.
PRODUCT DESCRIPTION Handle Air filter Air outlet Control Panel Air inlet Power supply cord Tube stopper Bucket CONTROL PANEL Water full indication FULL CON Operation indicator OFF RUNNING Defrost indicator DEFROST Humidity control knob OFF Switch off. CON Dehumidifier continuously running.
PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS BS PLUG WIRING Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : BLUE - NEUTRAL BROWN - LIVE GREEN AND YELLOW – EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: 1.
Specification M odel MEACO10L Basic R ated V oltage 220-240V ~ R ated F r equency 50H z C apacity 0.4 k g/h ( I S O 5 151) Power I nput 220W R ated I nput 250W H i. Side Pr essur e 1.7 M P a L ow Side Pr essur e 0.6 M P a R efr iger ant R 134a R efr i. C har ge 0.1 4k g W eight 10k g Warning: To reduce the risk of electric shock, always unplug this appliance from the electrical outlet immediately before cleaning or serving.
OPERATING INSTRUCTIONS Start Operation FULL the bucket full lamp illuminates when the unit is first switched on, remove the tank and replace it . RUNNI NG or CONTINUOUS to work DEFROST While turning on ( or off ) the machine , the defrost lamp will shine . Full Bucket Lamp The lamp will illuminate when the water container is full. To empty the unit, first unplug from power source then carefully remove the tank and empty the collected water.
CONTINUOUS DRAINAGE CONTINUOUS DRAINAGE Back of the unit not su For drainage permanent drainage. Tube stopper Soft cover Tube stopper the bucket for storage. PVC hose Correct Use When Drainage Hose Is Connected When using continuous drainage, the PVC hose must be placed below the drainage hole. Avoid uneven surfaces and do not 'kink' the hose.
MAINTENANCE Before clea from the outlet. EXTERIOR SURFACES OF THE UNIT Clean the dehumidifier by using a damp sponge, and dry it with a clean, soft cloth. Never use alcohol or any product containing solvents. Do not immerse unit in water. AIR FILTERS The air filters located inside the unit collect dust contained in the air. To keep the dust from clogging the unit, your unit must always be used with its air filters. The build up of dust reduces the efficiency of the dehumidifier.
Is the " Red " lamp blinking?(The tank is full or in a wrong position. Discard the water in the drainage tank, and then reposition the tank. 9 The tube temperature sensor has failed or is disconnected. The protection device is actuated and the unit cannot be started because the room too cool or too hot (in that case, please do not use the dehumidifier). The sensor must be repaired or reassembled by competent service MAINTENANCE Plug the power supply cord into the outlet.
Is the air filter clogged? Clean the air filter as instructed under "Caring for the dehumidifier". Is air intake port or discharge port obstructed? Remove whatever is obstructing the discharge port or intake port. Is the air filter clogged? Clean the air filter instructed under "Caring for the dehumidifier". function does not work. 10 Is the dehumidifier on an uneven surface? Use the unit on a level surface. Prompt: Put a cushion under the unit and help to reduce operation noise.
The humidity does not drop Is the room too big for the unit? Are windows or doors opened and closed frequently? Is there a device in the room such as a kerosene stove, which emits steam? Very little or no dehumidifying takes place, takes place. This happens if the temperature and/or humidity of the room is low. When the unit is first used, the discharged air smells musty.
The unit echoes If the unit is used in a room with wood flooring or in a small room, it may echo. The refrigerant may take some sound until circulation stabilises. There are some stains left in the drainage tank. This is water left from the dehumidifying test conducted at the factory, it does not indicate a problem. 12 The fan is running and the compressor does not work .
LONG TERM STORAGE At the end of the season. or when you do not plan to use the unit for an extended period of time, we recommend that you take the following steps. Remove water from the water bucket. If continuous drainage hose is connected, disconnect it. Disconnect the unit and wrap the power cord and plug. Clean the unit and store it, protecting it from dust. Store the unit in an upright position. Keep it in a cool, dry place and away from sunshine.
CUSTOMER SERVICE Thank you for choosing Meaco, we really appreciate it, this dehumidifier has been imported into the U.K. by; Please record, for future reference, your date of purchase and where you bought the dehumidifier Meaco (U.K.) Limited from here. Meaco House Parklands Railton Road Date of purchase………………….. ………….. Guildford GU2 9JX Purchased from www.meaco.com (if not then please record the supplier’s name below Telephone: 01483 234900/0500 418458 Email: customerservice@meaco.