Instruction manual

6
THE CONTROL PANEL
Power - Lights up when there is power to the dehumidifier, the unit bleeps three
times when it is turned on.
Tank Full - Lights up when the internal tank is full of water and needs to be emptied or
when the tank is incorrectly fitted.
Fault - Lights up when a fault is detected. Most common would be the air inlet
being blocked leading to the dehumidifier over heating internally. Clean the filter; make sure that the
dehumidifier is not next to a heat source (i.e. a radiator) and restart the dehumidifier after ten
minutes.
Fan - Press the Fan button to toggle between the three fan speeds, low, medium
and high. In High fan speed the machine defaults to a Continuous running mode. Water extraction
will increase in medium and high fan speeds because the regeneration heater will switch to maximum
power (this increases the running wattage of the dehumidifier as well and the amount of heat
delivered to the room).
Maximum * -Runs the dehumidifier until a relative humidity of 40%rh has been reached
the dehumidifier then it goes into the 30 minute cycle as detailed in bold below.
Normal * -Aims to achieve a relative humidity of 50%rh which will be fine for most
household applications. To prevent condensation on single glazed windows or when the outside
temperature drops below about 5°C you should use Maximum instead of Normal. Once 50% has
been reached the dehumidifier then goes into the 30 minute cycle as detailed in bold below.
Minimum * - Controls the relative humidity to 60%rh which will prevent mould from
growing in the immediate vicinity of the dehumidifier but not throughout a whole house. Once
60%rh has been reached the dehumidifier then goes into the 30 minute cycle as detailed in bold
below.