Datasheet

½ Features :
60WSingleOutputLEDPowerSupply
CEN-60 series
CEN-60-54
0~1.15A
62.1W
59~65V
40.5~54V
49~58V
0.9~1.15A
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
Features :
FileName:CEN-60-SPEC2010-09-01
SPECIFICATION
MODEL CEN-60-20 CEN-60-24 CEN-60-30 CEN-60-36CEN-60-12 CEN-60-15 CEN-60-48
CEN-60-42
DCVOLTAGE
CURRENTRANGE
RATEDPOWER
OUTPUT
LINEREGULATION
LOADREGULATION
SETUP TIME
VOLTAGERANGE
Note.4
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERCURRENT
SHORTCIRCUIT
OVERVOLTAGE
OVERTEMPERATURE
20V 24V 30V 36V 54V12V 15V 48V
42V
0~3A 0~2.5A 0~2A 0~1.7A0~5A 0~4A 0~1.3A
0~1.45A
60W 60W 60W 61.2W60W 60W 62.4W
60.9W
1.8Vp-p 2.4Vp-p 3Vp-p 3.6Vp-p 5Vp-p2Vp-p 2.4Vp-p 4.6Vp-p
4Vp-p
10%
3.0%
5.0%
1400ms/230VAC2800ms/115VACatfullload
90~295VAC 127~417VDC
47~63Hz
PF 0.9at75~100%load,115VAC/230VAC;PF>0.97/115VACPF>0.95/230VACatfullload
88% 89% 90% 90% 91%86% 87% 91%90%
22.8~26V 28~34V 34~38V 41~46V14.5~17V 17.5~21V 54~60V
47~52V
0.8A/115VAC0.4A/230VAC
45A/230VAC
<0.75mA /240VAC
95~110%
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
-30~+70 (Refertooutputloadderatingcurve)
20~95%RH non-condensing
-40~+80 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G12min./1cycle,periodfor72min.eachalongX, Y,Zaxes
523.4Khrsmin.MIL-HDBK-217F(25 )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
0.56Kg;24pcs/14.4Kg/1.11CUFT
Protectiontype: Shutdowno/pvoltage,re-powerontorecover
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
85 10 (RTH1)
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3.75KVACI/P-FG:1.88KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
CompliancetoEN55015
Complianceto ClassC( 75%load);EN61000-3-3
EN61000-3-2
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,EN61547,lightindustrylevel(surge4KV),criteria A
EMICONDUCTION&RADIATION
15~20V 18~24V 22.5~30V 27~36V9~12V 11.25~15V 36~48V
31.5~42V
RATEDCURRENT 3A 2.5A 2A 1.7A 1.15A5A 4A 1.3A
1.45A
CONSTANTCURRENT OPERATIONVOLTAGE Note.5
17~22V 22~27V 27~33V 33~40V10.8~13.5V 13.5~17V 43~53V
37~46V
VOLTAGE ADJ.RANGE (SVR1)
CURRENT ADJ.RANGE(SVR2) 2.3~3A
1.9~2.5A 1.5~2A 1.3~1.7A
3.75~5A 3~4A 1~1.3A
1.1~1.45A
IP66
110
SELV
F M M
UL8750, TUVEN61347-1,EN61347-2-13,IP66approved
183*62.5*40.5mm(L*W*H)

Summary of content (3 pages)