Data Sheet

SPECIFICATION - Power Supply System
File Name:DHP-1U RACK SYSTEM-SPEC 2019-03-22
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Under parallel
operation of more than one rack connecting together, ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to
normal ripple level once the output load is more than 5%.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Output of all the DRP-3200 modules are connected in parallel in the rack.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Because of component tolerance, there is a possibility that some of units connected in parallel will reach an overcurrent limit then overloading the other
units when operating at full load condition. If overload conditions happen in parallel usage, it is suggested that derate the total output current by 10%.
7. The equivalent leakage current of the system is determined by the quantity of populated rectifiers.
8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.21000 1300 For guidance on how
to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
DHP-12K1U -24 DHP-12K1U -48
MODEL
VOLTAGE RANGE
Note.5
RECTIFIER
OUTPUT VOLTAGE
MAX. OUTPUT CURRENT
MAX. OUTPUT POWER
Note.4
FREQUENCY RANGE
AC CURRENT (Typ.) per RECTIFIER
INPUT
OUTPUT
LEAKAGE CURRENT
per RECTIFIER
90 ~ 264VAC 127 ~ 370VDC
12864W
268A
48V
DRP-3200-24 DRP-3200-48
47 ~ 63Hz
<1.5mA / 230VAC
17A/230VAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
DIMENSION
PACKING
OTHERS
UL60950-1, TUV EN60950-1 approved
-30 ~ +70
, when 3 or 4 power/charger units are paralleled in power shelf, highest working temperature shall de-rate to 40 at full load
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Rack 400*482.6*44(L*W*H, with mounting bracket) ; 365*440*44(L*W*H, without mounting bracket)
ENVIRONMENT
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:700VDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
4.85Kg
; 3pcs/17.4Kg/1.8CUFT
ALARM SIGNAL
REMOTE ON-OFF CONTROL
AUXILIARY POWER
Isolated TTL signal output for T-Alarm, AC-OK and DC-OK
By electrical signal or dry contact ON:short OFF:open
5V @ 0.3A, tolerance 10%, ripple 150mVp-p, 12V @ 0.8A, tolerance 10%, ripple 450mVp-p±±
FUNCTION
SAFETY &
EMC
(Note 8)
12768W
532A
24V
DHP-1U Rack System
3200~12800W 1U Distributed Power/Charger System
REMOTE SENSE
Compensate voltage drop on the load wiring up to 0.5V
OUTPUT VOLTAGE PROGRAMMABLE(PV)
CONSTANT CURRENT LEVEL
PROGRAMMABLE(PC)
Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.
Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage. Please refer to the Function Manual.
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
Standard
Standard
EN55032 (CISPR32) / EN55011 (CISPR11)
EN55032 (CISPR32) / EN55011 (CISPR11)
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Class B
Class A
Class A
-----
EMC IMMUNITY
EMC EMISSION
EN55024 , EN61204-3, EN61000-6-2
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
Level 4, 2KV/Line-Line 4KV/Line-Earth
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Note.7