Datasheet

SPECIFICATION
DR-100-12 DR-100-15 DR-100-24
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD Note.6
OVER VOLTAGE
12V 15V 24V
7.5A 6.5A 4.2A
0 ~ 7.5A 0 ~ 6.5A 0 ~ 4.2A
90W 97.5W 100.8W
120mVp-p 120mVp-p 150mVp-p
±1.0% ±1.0%
15 ~ 18V 24 ~ 29V12 ~ 15V
±1.0%
±2.0%
±1.0% ±1.0%
±1.0% ±1.0% ±1.0%
2700ms, 80ms/230VAC 2700ms, 80ms/115VAC at full load
50ms/230VAC 18ms/115VAC at full load
88 ~ 264VAC 124 ~ 370VDC [DC input operation possible by connecting AC/L(+),AC/N(-)]
47 ~ 63Hz
87% 87% 89%
3A/115VAC 1.6A/230VAC
COLD START 30A/115VAC 45A/230VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
16 ~ 20V
Protection type : Shut down o/p voltage, re-power on to recover
19 ~ 23V 30 ~ 35V
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
486K hrs min. MIL-HDBK-217F (25)
100*93*56mm (W*H*D)
0.35Kg; 36pcs/13.6Kg/0.89CUFT







File Name:DR-100-SPEC 2014-03-14
Compliance to EN61204-3, EN55022 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
100W Single Output Industrial DIN Rail Power Supply
DR-100 series










RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH
UL60950-1, TUV EN60950-1 approved, design refer to EN50178
..
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
EMC IMMUNITY
EMC EMISSION

Summary of content (2 pages)