Datasheet

SPECIFICATION
DR-60-5 DR-60-12 DR-60-15 DR-60-24
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V 15V 24V
6.5A 4.5A 4A 2.5A
0~6.5A 0~4.5A 0~4A 0~2.5A
32.5W 54W 60W 60W
80mVp-p 120mVp-p 120mVp-p
13.5~16.5V
150mVp-p
21.6~26.4V
2.0% 1.0% 1.0% 1.0%
11.1~13.2V4.75~5.5V
1.0% 1.0% 1.0% 1.0%
1.0% 1.0% 1.0% 1.0%
100ms,30ms/230VAC200ms,30ms/115VAC atfullload
100ms/230VAC23ms/115VAC atfullload
88~264VAC124~370VDC
47~63Hz
76% 82% 83% 84%
1.2A/115VAC0.8A/230VAC
COLDSTART 18A/115VAC36A/230VAC
105~160% ratedoutputpower
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
5.75~6.75V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
13.8~16.2V 17.25~20.25V 27.6~32.4V
-20~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
216.2Khrsmin.MIL-HDBK-217F(25 )
78*93*56mm(W*H*D)
0.3Kg;48pcs/15.4Kg/1.02CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
FileName:DR-60-SPEC2005-09-13
CompliancetoEN55011,EN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3Heavyindustrylevel,criteria A
60WSingleOutputIndustrialDINRailPowerSupply
DR-60 se ri es
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
Isolation class
LED indicator for power on
100% full load burn-in test
3 years warranty
Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
EMICONDUCTION&RADIATION
I/P-O/P:3KVAC
I/P-O/P:100MOhms/500VDC
UL60950-1, TUVEN60950-1 EN50178Approved,Designreferto

Summary of content (2 pages)