SPECIFICATION
DRP-240-24 DRP-240-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
24V 48V
10A 5A
0 ~ 10A 0 ~ 5A
240W 240W
80mVp-p 150mVp-p
24 ~ 28V 48 ~ 53V
±1.0%
±0.5% ±0.5%
±1.0%
±1.0%
±1.0%
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
84% 85%
54 ~ 60V
2.8A/115VAC 1.4A/230VAC
COLD START 27A/115VAC 45A/230VAC
<3.5mA / 240VAC
105 ~ 150% rated output power
30 ~ 36V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
289.9Khrs min. MIL-HDBK-217F (25 )
125.5*125.2*100mm (W*H*D)
1.2Kg; 12pcs/15.5Kg/1.29CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:DRP-240-SPEC 2017-07-07
..
UL508, UL60950-1, TUV EN60950-1 approved
Compliance to EN55011,EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
240W Single Output Industrial DIN RAIL Power Supply
DRP-240 series
Features :
Universal AC input / Full range
Built in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
3 years warranty
ENVIRONMENT
PROTECTION
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
800ms, 40ms/230VAC 800ms, 40ms/115VAC at full load
24ms/230VAC 24ms/115VAC at full load
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
POWER FACTOR (Typ.) 0.96/230VAC 0.99/115VAC at full load
EMC IMMUNITY
EMC EMISSION