Datasheet

SPECIFICATION
DRP-240-24 DRP-240-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
HARMONICCURRENT
SAFETY &
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
24V 48V
10A 5A
0~10A 0~5A
240W 240W
80mVp-p 150mVp-p
24~28V 48~53V
1.0%
0.5% 0.5%
1.0%
1.0%
1.0%
85~264VAC120~370VDC
47~63Hz
84% 85%
54~60V
2.8A/115VAC1.4A/230VAC
COLDSTART 27A/115VAC45A/230VAC
<3.5mA /240VAC
105~150% ratedoutputpower
30~36V
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
100 5 (TSW1)
Detectonheatsinkofpowertransistor
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
-10~+70 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
105.5Khrsmin.MIL-HDBK-217F(25 )
125.5*125.2*100mm(W*H*D)
1.2Kg;12pcs/15.5Kg/1.2CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
FileName:DRP-240-SPEC2005-06-20
UL508, TUVEN60950-1 ApprovedUL60950-1,
CompliancetoEN55011,EN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2)Heavyindustrylevel,criteria A
240WSingleOutputIndustrialDINRAIL PowerSupply
DRP-240 se ri es
Features :
Universal AC input / Full range
Built in active PFC function
Protections:Short circuit/Over load/Over voltage/Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
3 years warranty
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
800ms,40ms 00ms,40ms/230VAC8 /115VACatfullload
24ms ms/230VAC24 /115VACatfullload
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
R
POWERFACTOR (Typ.) 0.96/230VAC0.99/115VACatfullload