Datasheet

SPECIFICATION
MODEL
OUTPUT
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER TEMPERATURE
OVER VOLTAGE
500ms, 100ms/230VAC, 1000ms, 100ms/115VAC
10ms/ 230VAC 10ms/ 115VAC
47 ~ 63Hz
2.2A / 115VAC 1.5A / 230VAC 1.2A/277VAC
<0.75mA / 277VAC
Compliance to
EN55015
,EN61000-3-2 Class C (@load 50%) ; EN61000-3-3;GB17625.1,GB17743 ;EAC TP TC 020; K
C KN15 KN61547,
20 ~ 95% RH non-condensing
-40 ~ + , 10 ~ 95% RH90
±℃ 0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
ENVIRONMENT
EMC EMISSION
SAFETY &
EMC
PROTECTION
Shut down output voltage, re-power on to recover
Shut down output voltage, re-power on to recover
SHORT CIRCUIT
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
TOTAL HARMONIC DISTORTION
DC VOLTAGE
RATED CURRENT
RATED POWER
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
RIPPLE & NOISE (max.) Note.3
VOLTAGE TOLERANCE
Note.4
CONSTANT CURRENT REGION Note.2
OVER CURRENT
SAFETY STANDARDS
Adjustable for A/AB-Type only (via built-in potentiometer)
Adjustable for A/AB-Type only (via built-in potentiometer)
COLD START 60A(twidth= s measured at 50% Ipeak) at 230VAC510μ;Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
MAX. CASE TEMP.
Tcase=+90
UL8750 independent, EN62384;(type”HL”), CSA C22.2 No. 250.13-12;IEC/EN/AS/NZS 61347-1, IEC/EN/AS/NZS 61347-2-13
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level ( )surge immunity Line-Earth 6KV, Line-Line 4KV ;EAC TP TC 02; K
C KN15 KN61547,
(Please refer to "STATIC CHARACTERISTIC" section)
100 ~ 305VAC 142 ~ 431VDC
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. No load/standby power consumption is specified for 230VAC input.
8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70 or less.
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
11. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
12. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
180~240W Constant Voltage + Constant Current LED Driver
95 ~ 108%
Hiccup mode, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
No load power consumption <0.5W for Blank / A / Dx / D-Type
NO LOAD / STANDBY
POWER CONSUMPTION
Note.7
Standby power consumption <0.5W for B / AB / DA-Type
Tcase=-40 ~ +90 (Please refer to OUTPUT LOAD vs TEMPERATURE” section)
ELG-240-54
ELG-240-48
ELG-240-36
ELG-240-24
ELG-240-42
54V
48V
36V
24V
42V
10A
5.71A
6.66A
5.0A
350mVp-p
27 ~ 54V
240.3W
4.45A
250mVp-p
24 ~ 48V
240W
250mVp-p
18 ~ 36V
239.76W
200mVp-p
12 ~ 24V
240W
250mVp-p
21 ~ 42V
239.82W
22.4 ~ 25.6V
33.5 ~ 38.5V
39 ~ 45V
44.8 ~ 51.2V
50 ~ 57V
2.23 ~ 4.45A
2.5 ~ 5A
3.33 ~ 6.66A
5 ~ 10A
2.86 ~ 5.71A
±2.0%
±0.5%
±0.5%
±2.0%
±0.5%
±0.5%
±2.0%
±0.5%
±0.5%
±2.0%
±0.5%
±0.5%
±2.0%
±0.5%
±0.5%
93%
93%
92%
92%
92.5%
60 ~ 67V
54 ~ 63V
42 ~ 49V
27 ~ 34V
47 ~ 54V
826.7K hrs min. Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25 )
244 71* *37.5mm (L*W*H)
1.22Kg; 12pcs / 15.2Kg / 0.72CUFT
EAC TP TC 004;BIS IS15885(for 24/24B/36/36A/42/42A/48/48A/54/54A only) GB19510.14,GB19510.1; IP65 or IP67;;
approvedKC61347 1 KC61347 2 13-, --
DALI STANDARDS
ELG-240 series
180W
180W
180W
179.76W
180.36W
200VAC ~ 305VAC
100VAC ~ 180VAC
File Name:ELG-240-SPEC 2018-09-30
Compliance to IEC62386-101, 102, 207 for DA-Type only