SPECIFICATION
MODEL ELP-75-3.3
ELP-75-12
ELP-75-5 ELP-75-15
ELP-75-24
ELP-75-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.6
FREQUENCY RANGE
POWERFACTOR (Typ.) Note.5
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V
12V
5V 15V
24V
48V
15A
6.25A
15A 5A
3.15A
1.6A
0~15A
0~6.25A
0~15A 0~5A
0~3.15A
0~1.6A
49.5W
75W
75W 75W
75.6W
76.8W
80mVp-p
120mVp-p
80mVp-p 150mVp-p
240mVp-p
300mVp-p
3~3.6V
10.8~13.2V
4.75~5.5V 13.5~16.5V
21.6~26.4V
43.2~52.8V
3.0%
0.5%
2.0%
2500ms,50ms/230VAC2500ms,50ms/115VAC atfullload
20ms/230VAC20ms/115VAC atfullload
90~264VAC127~370VDC
47~63Hz
3.3V: PF>0.95/230VACPF>0.98/115VACatfullloadPF>0.91/230VAC5V~48V:
3.7~4.45V 5.6~6.75V
13.8~16.2V
17.25~20.25V 27.6~32.4V
53.3~64.8V
80% 89%82% 90% 90% 90%
1.8A/115VAC1 A/230VAC
COLDSTART 60A/230VAC
105~150% ratedoutputpower
CompliancetoEN55022(CISPR22)ClassB,EN61000-3-2,-3
-30~+70
(Referto"DeratingCurve")
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
345.3Khrsmin.MIL-HDBK-217F(25 )
PCB: withoptionalCASE:195*68.5*33mm(L*W*H)175*60*27mm(L*W*H)
75WSingleOutputwithPFCFunction
ELP-75 se ri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/500VDC/25 /70%RH
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. 3.3V PF>0.92/230VAC, others PF>0.95/230VAC.
6. Derating may be needed under low input voltage. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
Features :
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
UL60950-1, TUVEN60950-1approved
Complianceto ,heavyindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11;EN55024
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
3 years warranty
Optional L-Bracket and cover (ELP-75-x-C, x=3.3,5,12,15,24,36,48)
Built-in active PFC function, PF>0.95
High efficiency up to 90%
1U low profile
LED indicator for power on
No load power consumption<0.5W
<1mA/240VAC
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
PCB:0.25Kg;48pcs/13Kg/0.85CUFT withoptionalCASE:0.54Kg;25pcs/14.5Kg/0.59CUFT
FileName:ELP-75-SPEC2011-05-09
2.0%
0.5%
1.5%
2.0%
0.5%
1.0%
2.0%
0.5%
1.0%
1.0%
0.5%
1.0%
1.0%
0.5%
1.0%
ELP-75-36
36V
2.1A
0~2.1A
75.6W
280mVp-p
32.4~39.6V
1.0%
0.5%
1.0%
90%
39.7~46.8V
EMCIMMUNITY
EMCEMISSION