Datasheet

SPECIFICATION
ORDER NO.
DC VOLTAGE (Typ.)
SAFETY MODEL NO.
RATED POWER
OUTPUT
VOLTAGE RANGE
Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 5)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBR ATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GC120A24- GC120A48-
GC120A24 GC120A48
GC120A12-
GC120A12
27.2V 54.4V13.6V
LED INDICATOR Charging(CC) : RED Floating charging(CV) : GREEN
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.97 / 230VAC PF>0.99 / 115VAC at full load
90%
29 ~ 33V
91%
59 ~ 69V
86.5%
1.4A / 115VAC 0.7A/ 230VAC
70A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISO LATION RESISTANCE
I/P-O/P: 3KVAC
I/P-O/P / 25 / 70% RH:100M Ohms / 500VDC
400.7K hrs min. MIL-HDBK-217F(25 )
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
± 0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
167*67*35mm (L*W*H)
0.62Kg; 20pcs/13.4Kg/0.9CUFT
CONNECTOR
PLUG
CABLE See page 2 ther type available by customer requested; O
See page 2 ther type available by customer requested; O
               
                 
               
         
                     
 

Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OVERLOAD
Note.4
OVER VOLTAGE
90 ~ 110% rated output power
Protection type : Constant current limiting recovers automatically after fault con dition is removed
Protection type : Hiccup mode, recovers automatically af ter fault condition is removed
14 ~ 16.5V
120.2W 120.2W102W
Protection type : Shut down o/p voltage, re-power on to recover
UL1012 (for GC120Axx-AD1 only), TUV EN60950-1 approved
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, EN61000-3-2,3
  
    
   
  
    
       
  
     

 
    
   
OVER TEMPERATURE
100 10 (RTH2) de tect on inside ambient temperature±
Protection type : Shut down o/p voltage, re-power on to recover
G C1 20
s e r i es
120W Single Output Battery Charger
RECOMMENDED BATTERY
CAPACITY
Note.2
CURRENT (Typ.)
CONTINUOS OUTPUT
20 ~ 65Ah
4.42A
10 ~ 35Ah
2.21A
40 ~ 100Ah
7.5A
SHORT CIRCUIT
F ile Na me:G C120 -SPEC 201 1-08- 09
ORDER NO. OUTPUT CONNECTOR SAFETY
GC120Axx-R7B (standard model) 4pin power din TUV / CB / FCC / CE
GC120Axx-AD1 (optional model)
=R7B,AD1GC120Axx- xx=12,24,48 ;
Anderson connector UL / TUV / CB / FCC / CE
   