User manual

2
At the beginning stage of operation, the charger provides the largest current with 40.8V dc of output voltag e (for 36V batteries) to
charg e batt eries. The LED indicator will lighten in red. After a period of time (probably a coup le of hours, based on the capacity of
batte ries), the charging current will decrease gradually. After reaching of its maximum value, the charger will go into
"floating-charge" stage. The LED ind icator will turn to green. The relationship between charg ing current and charging voltage for each
opera tion stage are shown in t he cur ves below :
Statu s Under General Operation:
0.3A 0.1A±
Chargin g Curr ent And Am bient Temperature
EXTERNA L CASE TEMPERATURE ( )
Suggested Battery Capac ity:
1.It will n ot have any problem if the capacity of batteries larger than the suggested value. It j ust takes more time to make the batter ies
2.If you have any question about the suitable chargin g curr ent for the b atterie s, plea se ref er to th e tech nical d ata pr ovided by th e
fully charge d!
batte ry man ufactu rers o r cons ult the vendo r of th e batte ries.
Notes On Failure Elimination
Status
No output
vo ltage
Possible Re asons
Repair required. Please
send i t back to us o r any
of our distributors
Wrong polarity of the battery
con nection
Ways to Elimi nate
Mod el
GC33 0A36 20-65Ah
GC33 0A48 20-65Ah
Suggested Batt ery capacity
If you still cannot eliminate the failure situation, please consult
Can't achieve
the FLOAT
(green light)
stage after
lo ng period
of charging
operation
Replace the batteriesBa tteries are aging or broken
MEAN WELL or any of our distributors
0-3 0 2010 30 40
20
40
80
60
100
6050 70
(HORIZONTAL)
50
TIME
V
0.3A 0.1A±
Constant Voltage Area
Stage 2
Float Charging
I
(V,I)
Constant Current Area
Fast Charging
Stage 1
Red Green
Color of LED