Datasheet

SPECIFICATION
TYPE
ORDER NO.
Australian type U.K type European type US type
Mix four type
AC plug-AU AC plug-UK AC plug-EU AC plug-US
AC plug-MIX
GE24 05-P1J GE24 07-P1J GE24 09-P1J GE24 12-P1J GE24 15-P1J GE24 18-P1J GE24 24-P1J GE24 48-P1J
IIIIIII
IIII
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
POWER SUPPLY MAIN BODY ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
SAFETY STANDARDS
SAFETY &
EMC
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
LIFE
DIMENSION
OTHERS
DC OUTPUT
NOTE
PLUG
CABLE
OVERLOAD
OVER VOLTAGE
9V7.5V5V
12V 15V 18V 24V 48V
2.22A2.0A3.0A
2.0A 1.6A 1.33A 1.0A 0.5A
CURRENT RANGE 0 ~ 2.22A0 ~ 2.0A0 ~ 3.0A
0 ~ 2.0A 0 ~ 1.6A 0 ~ 1.33A 0 ~ 1.0A 0 ~ 0.5A
RIPPLE & NOISE (max.)
Note.3
100mVp-p75mVp-p50mVp-p
120mVp-p 150mVp-p 180mVp-p 240mVp-p 300mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±3.0% ±3.0% ±3.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0%
±5.0%
±5.0%
±5.0%
±1.0% ±1.0% ±1.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±3.0% ±3.0% ±3.0% ±3.0%
4000ms, 100ms, 30ms / 230VAC 4000ms, 100ms, 10ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
0.7A / 100VAC 0.4A / 230VAC
COLD START 40A / 100VAC 80A / 230VAC
0.25mA / 240VAC
110% ~ 200% rated output power
115% ~ 135%
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
100Khrs min. MIL-HDBK-217F (25 )
2 years : 100% load 30 , 8 hours / day
-10 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
81*43*40.5mm (L*W*H)
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Main body unit and AC inlet plug should be ordered seperately ; it needs to be used along with any of the AC inlet plug.
CONNECTOR
FRA024-S05- FRA024-S07- FRA024-S09- FRA024-S12- FRA024-S15- FRA024-S18- FRA024-S24- FRA024-S48-
RATED POWER (max.)
24W 24W20W15W15W
24W 24W 24W
Standard type P1J: 2.1 * 5.5 * 11mm turning fork type, center positive for stock ; Other type available by customer requestedψψ
See page2
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode
ENVIRONMENT
PROTECTION
File Name:GE24-SPEC 2014-11-04
15 ~ 24W AC-DC Single Output Interchangeable Wall-mounted type
GE24 series
UL60950-1, CSA C22.2, TUV EN60950 -1, CCC GB4943 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
PACKING
134g ; 50pcs / 8.4kg / CARTON
81.5%79.5%76.5%
82.5% 84%
84% 85% 85%
I
II I I
I
I
I
I
I
I
I
I
I
I
Features :
Interchangeable AC plugs (plug kit sold seperately)
Universal AC input / Full range
No load power consumption< 0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act) for 5~48V
Class power (without earth pin)II
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Pass LPS
Approvals: UL / CUL / TUV / CCC / CB / FCC / CE / C-Tick
2 years warranty
AC INLET PLUG
EMC IMMUNITY
EMC EMISSION

Summary of content (2 pages)