Data Sheet

File Name:HBG-100-SPEC 2018-09-30
SPECIFICATION
HBG-100 series
MODEL
OUTPUT
VOLTAGE RANGE
Note.3
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
Note.5
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VACμ;Per NEMA 410
<0.75mA / 277VAC
95 ~ 108%
Constant current limiting
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
985.6K hrs min. Telcordia SR-332 (Bellcore) ; Khrs min. MIL-HDBK-217F (25 )300
Shut down o/p voltage re-power on to recovery
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage re-power on to recovery
EMC IMMUNITY
EMC EMISSION Note.7
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ; EN61000-3-3()@load 60% , GB17743 and GB17625.1, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level ( )surge immunity:Line-Earth:4KV,Line-Line:2KV , EAC TP TC 020
CURRENT ADJ. RANGE
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC
(Please refer to "STATIC CHARACTERISTIC" section)
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC full load@
(Please refer to " " )POWER FACTOR (PF) CHARACTERISTIC section
THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
WORKING TEMP.
Tcase=-40 ~ +85 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.
Tcase=+85
Adjustable for A/AB-Type (via built-in potentiometer)
90.5%
91%
91.5%
91%
28 ~ 35V
41 ~ 49V
65 ~ 75V
54 ~ 63V
CONSTANT CURRENT REGION
Note.2
RATED CURRENT
RATED POWER
SETUP TIME
Note.4
CURRENT TOLERANCE
CURRENT RIPPLE
HBG-100-24
HBG-100-36
HBG-100-60
HBG-100-48
25V
37V
62V
49V
14.4 ~ 24V
21.6 ~ 36V
36 ~ 60V
28.8 ~ 48V
4A
96W
2.7A
97.2W
1.6A
96W
2A
96W
2.4 ~ 4A
1.62 ~ 2.7A
1.2 ~ 2A
1.0 ~ 1.6A
±5.0%
5.0% max. @rated current
2000ms / 115VAC 500ms / 230VAC
1.1A / 115VAC 0.5A / 230VAC 0.45A / 277VAC
UL8750(type”HL”),CSA C22.2 No.250.13-12, ENEC EN61347-1, GB19510.1,GB19510.14EN61347-2-13 independent, EN62384; ,
BIS IS15885(for 36A,48A,60A only), P approvedIP65 or I 67EAC TP TC 004,
1.18Kg; 12pcs/15.7Kg/1.43CUFT(Blank/A/B Type),1.89CUFT(E Type)
100W Constant Current Mode LED Driver
OPEN CIRCUIT VOLTAGE(max.)
ψ130mm *66.5mm (D * H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.
2. Please refer to "DRIVING METHODS OF LED MODULE".
3.
De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
5. The DA type power supply is less efficient than the typical efficiency in specification by 1%.
6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected
by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently
connected to the mains.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less.
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
11. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
DALI STANDARDS
Compliance to IEC62386-101, 102, 207 for DA-Type only