Data Sheet

Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL
for other options.
Using a switch and relay can turn ON/OFF the lighting fixture.
NFG L
Relay
Blue
Brown
Green/
Yellow
AC/L
AC/N
B-Type
DIM+
DIM-
V(-)
V(+)
Blue
White
Black
Red
Switch Adjuster
10K/N~100K/N Ohms resistance
1~10V DC Voltage
10V PWM Signal
LED Lighting Fixture
HBG-100
HBG-100 series
File Name:HBG-100-SPEC 2018-09-30
100W Constant Current Mode LED Driver
DAL Interface (primary side; for DA-Type)I
Apply DALI signal between DA+ and DA-.
DAL protocol comprises 16 groups and 64 addresses. I
First step is fixed at 8% of output.