Data Sheet
SPECIFICATION
HBG-160 series
CONSTANT CURRENT REGION Note.2
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.) Note.7
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
COLD START 65A(twidth=550 s measured at 50% Ipeak) at 230VACμ ; Per NEMA 410
<0.75mA / 277VAC
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
20 ~ 95% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
783.1K hrs min. Telcordia SR-332 (Bellcore) ; 252.3Khrs min. MIL-HDBK-217F (25℃)
1.53Kg; 8pcs/13.8Kg/1.61CUFT
Shut down o/p voltage with auto-recovery or re-power on to recovery
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
UL8750(type”HL”),CSA C22.2 No.250.13-12, TUV EN61347-1,EN61347-2-13; BIS IS15885(for 36A,48A,48B,60A,60DA only),
EAC TP TC 004, GB19510.1,GB19510.14, IP65 or IP67 approved, design refer to TUV EN60950
EMC IMMUNITY
EMC EMISSION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3, GB17743 and GB17625.1,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level (surge immunity:Line-Earth:4KV,Line-Line:2KV), EAC TP TC 020
CURRENT ADJ. RANGE
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
(Please refer to "STATIC CHARACTERISTIC" section)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
Tcase=-40 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.
Tcase=+85℃
160W Constant Voltage + Constant Current LED Driver
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
RIPPLE & NOISE (max.) Note.3
VOLTAGE TOLERANCE Note.4
2500ms, 200ms / 115VAC 500ms, 200ms / 230VAC
12ms /115VAC, 230VAC
±2.0%
±0.5%
±1.0%
24V
14.4 ~ 24V
6.5A
156W
200mVp-p
HBG-160-24
36V
21.6 ~ 36V
4.4A
158.4W
300mVp-p
HBG-160-36
60V
36 ~ 60V
2.6A
156W
300mVp-p
HBG-160-60
48V
28.8 ~ 48V
3.3A
158.4W
300mVp-p
HBG-160-48
3.9 ~ 6.5A
2.6 ~ 4.4A
1.98 ~ 3.3A
1.6 ~ 2.6A
Adjustable for A/AB-Type (via built-in potentiometer)
1.7A / 115VAC 0.78A / 230VAC 0.7A / 277VAC
92%
92%
93.5%
93%
28 ~ 34V
41 ~ 47V
65 ~ 75V
54 ~ 62V
ψ151.68mm *66.5mm (D * H)
℃
℃
℃℃
DALI STANDARDS
Compliance to IEC62386-101, 102, 207 for DA-Type only
File Name:HBG-160-SPEC 2019-01-03