Data Sheet
SPECIFICATION
15W Ultra Slim Step Shape DIN Rail
HDR-15 series
HDR-15-5
HDR-15-12 HDR-15-15 HDR-15-24
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD Note.4
OVER VOLTAGE
5V
12V 15V 24V
2.4A
1.25A 1A 0.63A
0 ~ 2.4A
0 ~ 1.25A 0 ~ 1A 0 ~ 0.63A
12W
15W 15W 15.2W
80mVp-p
120mVp-p 120mVp-p 150mVp-p
±2.0%
±1.0% ±1.0% ±1.0%
±1.0%
±1.0% ±1.0% ±1.0%
±1.0%
±1.0% ±1.0% ±1.0%
2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load
30ms/230VAC 12ms/115VAC at full load
47 ~ 63Hz
80%
85% 85.5% 86%
0.5A/115VAC 0.25A/230VAC
COLD START 25A/115VAC 45A/230VAC
110 ~ 145% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut off o/p voltage, clamping by zener diode
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03%/℃ (0 ~ 50℃) RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
1166K hrs min. MIL-HDBK-217F (25℃)
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 5)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
17.5*90*54.5mm (W*H*D)
78g;160pcs/13.5Kg/1.19CUFT
EMC IMMUNITY
EMC EMISSION
HDR-15-48
48V
0.32A
0 ~ 0.32A
15.4W
240mVp-p
±1.0%
±1.0%
±1.0%
87%
5.75 ~ 6.75V
14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V
56.5~ 64.8V
13.5 ~ 18V
21.6 ~ 29V
10.8 ~ 13.8V
4.5 ~ 5.5V
43.2 ~ 55.2V
85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational )
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
Standard
EN61000-3-2
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Radiated Susceptibility
EFT/Burest
Surge
Standard
EN61000-4-2
Test Level /Note
Conducted
Magnetic Field
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11
Voltage Dips and interruptions
EN55032(CISPR32), CNS13438
Level 3, 8KV air; Level 2, 4KV contact, criteria A
Level 4,2KV/L-N, criteria A
Level 3, criteria A
Level 3, criteria A
Level 3, criteria A
Level 4, criteria A
EN55032(CISPR32), CNS13438
UL60950-1, U 508, TUV EN61558-2-16 IEC60950-1, , BSMI CNS14336-1 aL , pproved; Design refer to TUV EN60950-1 EAC TP TC 004
OPERATING ALTITUDE
2000 meters
℃
℃℃
EN55024, EN55035, EN61000-6-2, EN61204-3
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
μμ
OVER VOLTAGE CATEGORY
Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
File Name:HDR-15-SPEC 2018-01-12