Datasheet
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.6
CURRENT ADJ. RAN GE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.8
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT( .)Typ
LEAKAGE CURRENT
SAFETY STANDARDS
Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIEN T
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKI NG
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMP ERATURE
Can be adjusted by internal potentiometer A type only
1500ms, 80ms / 115VAC 0ms, 80ms / 230VAC at full loadat full load 100
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
<0.7 5mA / 277VAC
95 ~ 108%
Protection type : Constant cur rent lim iting, recovers automatically after fault condition is removed
-40 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
± ℃ ℃0.0 3%/ (0 ~ 60 )
10 ~ 500Hz, 5G 1 2min./1cycle, period for 72min. each along X, Y, Z axes
336.5K hrs min. MIL-HDBK-217F (25 )℃
171*61.5*36.8mm (L*W *H)
℃
0.73Kg; 20p cs/15 .6Kg/0 .9CUFT
Protection type : Shut down o/p voltage, re-power on to recover
40W Single Ou tput Switching Power Supply
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
■
HLG - 40 H
se ri e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERA NCE
Note.3
ENVIRO NMENT
SAFETY &
EMC
PROTECTION
85 10 (RTH2)℃± ℃
Protection type : Shut down o/p voltage, re-power on to recover
IP65 IP67
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVA C I /P-FG :2KVAC O /P-FG :0.5KVAC
I/P-O/P, I/P -FG, O/P-F G:100M Ohm s / 50 0VDC / 25 / 70% RH℃
CONSTANT CURRENT REGION
Note.4
18 ~ 24V15 ~ 21V 23 ~ 3 0V
28 ~ 35V
35 ~ 43V
41 ~ 49V
48 ~ 58V 59 ~ 68V
54 ~ 65V
86.5%
86.5%
88%
88%
88.5%
88.5%
89.5%88.5% 89.5%
±2.5%
2 ~ 3.33A
±2.0%
1.6 ~ 2.67A
±1.0%
1.2 ~ 2 A
±1.0%
1 ~ 1.67A
±1.0%
0.8 ~ 1.34A
±1.0%
0.67 ~ 1.12A
±1.0 %
0.5 ~ 0.84A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5 %
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5 %
±1.0%
0.45 ~ 0.75A
±0.5%
±0.5%
±1.0%
0.58 ~ 0.96A
±0.5%
±0.5%
12V
HLG-40H-12 HLG-40H-15 HLG-40H-20 HLG-40H-24 HLG-40H-30 HLG- 40H-36 HLG-40H-42 HLG-40H-48 HLG- 40H-54
7.2 ~12V
15V
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
3.33A 2.67A 2A 1.67A
1.34A
1.12A
0.84A
39.96W 40.05W 40W 40.08W 40.2W
40.32W
40.32W
150mVp-p 150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
200mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
300mVp-p
44 ~ 53V10.8 ~ 13.5V
54V
32.4 ~ 54V
0.75A
40.5W
300mVp-p
49 ~ 58V
42V
25.2 ~ 42V
0.96A
40.32W
200mVp-p
40 ~ 46V
Compliance to EN55015, EN61000-3-2 Class C ( 60% load ) ; EN61000-3-3≧
Compliance to EN 61000-4-2,3 ,4,5,6,8,11; EN61547, EN55024, light indust ry level (surge 4KV), crite ria A
EMC IMMUNITY
EMC EMISSION
SHORT CIRCUIT
Hiccup mode, recovers automatically after fa ult condition is removed
UL8 750, C SA C2 2.2 No. 250 .0-08 ( excep t for 4 8V, 54V), EN61347 -1, EN6134 7-2-13 indep endent, IP65 or IP 67, J6 1347-1,
J61347-2-13 approved ; design ref er to U L60950-1, T UV EN 60950-1, EN6033 5-1
COLD START 50A(t =210 s measured at 50% I ) at 230VAC
width peak
μ