Datasheet
SPECIFICATION
MODEL
RATED CURRENT
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.2
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.3
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER TEMPERATURE
OVER VOLTAGE
Can be adjusted by internal potentiometer A type only
16ms at full load 230VAC / 115VAC
500ms, 80ms at full load 230VAC /115VAC
90 ~ 305VAC 127VDC ~ 431VDC
47 ~ 63Hz
0.88A / 115VAC 0.45A / 230VAC 0.38A / 277VAC
<0.75mA / 277VAC
-40 ~ +70 (Refer to "Derating Curve")℃
10 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
309.7K hrs min. MIL-HDBK-217F (25 )℃
195.6*61.5*38.8 mm (L*W*H)
RIPPLE CURRENT
ENVIRONMENT
SAFETY &
EMC
PROTECTION
300 ~ 340V
Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
SHORT CIRCUIT
91.5%
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
HLG-80H-C350 HLG-80H-C700
±5%
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Derating may be needed under low input voltages. Please check the static characteristics for more details.
3. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1.
4. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
5. Refer to warranty statement.
6. Please refer to "DRIVING METHODS OF LED MODULE".
7. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 or IP67 approved
Hiccup mode, recovers automatically after fault condition is removed
210 ~ 350mA 420 ~ 700mA
350mA
89.95W
A type : 128V ~ 257V B type : 167V ~ 257V
0.84Kg; 16pcs/14.4Kg/0.54CUFT
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
91.5%
150 ~ 170V
700mA
90.3W
A type : 64V ~ 129V B type : 84V ~ 129V
■ Features :
A : IP65 rated. Constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D
(option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
Constant current design
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 91.5%
Protections: Short circuit / Over voltage / Over temperature
Cooling by free air convection
Output current adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or 10V PWM signal or resistance)
Suitable for dry / damp / wet locations
5 years warranty (Note.5)
FMM
110
IP65 IP67
HLG-80H-C350
A
90W Single Output LED Power Supply
HLG-80H-C series
File Name:HLG-80H-C-SPEC 2015-05-11
EMC IMMUNITY
EMC EMISSION
CURRENT ACCURACY ±5.0%
Compliance to EN55015, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3≧
CONSTANT CURRENT REGION
Note.6
RIPPLE & NOISE
1Vp-p 0.5Vp-p
±1%LINE REGULATION
±1%
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC
COLD START 60A(t =410 s measured at 50% I ) at 230VACwidth peak
μ