Datasheet

Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89%
Protections: Short circuit / Overload / Over voltage / Over temperature
5 years warranty
Withstand 300VAC surge input for 5 seconds
Cooling by free air convection
Built-in constant current limiting circuit
1U low profile 38mm
Built-in remote sense function
SPECIFICATION
HRP-150-3.3 HRP-150-5 HRP-150-7.5 HRP-150-12 HRP-150-15 HRP-150-24 HRP-150-36 HRP-150-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
OUTPUT VOLTAGE ADJ.RANGE
VOLTAGETOLERANCE Note.3
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
PROTECTION
ACCURRENT (Typ.)
3.3V 5V 7.5V 12V 15V 24V 36V 48V
30A
26A 20A 13A 10A 6.5A 4.3A 3.3A
0~30A 0~26A 0~20A 0~13A 0~10A 0~6.5A 0~4.3A 0~3.3A
99W 130W 150W 156W 150W 156W 154.8W 158.4W
80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
2.8~3.8V 4.3~5.8V 6.8~9V 10.2~13.8V 13.5~18V 21.6~28.8V 28.8~39.6V 40.8~55.2V
2.5% 2.5% 2.5% 1.5% 1.5% 1.5% 1.5% 1.5%
0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2%
1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5%
3000ms,50ms/230VAC3000ms,50ms/115VACatfullload
16ms/230VAC16ms/115VACatfullload
85~264VAC120~370VDC
47~63Hz
PF>0.95/230VACPF>0.99/115VACatfullload
78.5% 85%
6~7V 9.4~10.9V 14.4~16.8V 18.8~21.8V 30~34.8V 41.4~48.6V 57.6~67.2V
87% 88% 88% 88% 89% 89%
2.3A/115VAC1.3A/230VAC
35A/115VAC70A/230VAC
<1mA /240VAC
105~135%ratedoutputpower
3.96~4.62V
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
Protectiontype: ,recoversautomaticallyaftertemperaturegoesdownShutdowno/pvoltage
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024 ,heavyindustrylevel,criteria A,EN61000-6-2
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
-40~+70 (Referto"DeratingCurve")
20~90%RHnon-condensing
-50~+85 ,10~95%RH
0.04%/ (0~50
10~500Hz,5G10min./1cycle,60min.eachalongX, Y,Zaxes
238.8Khrsmin.MIL-HDBK-217F(25 )
159*97*38mm(L*W*H)
0.61Kg;24pcs/15.6Kg/0.76CUFT
FileName:HRP-150-SPEC2011-06-21
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
HRP-150 se ri es
150WSingleOutputwithPFCFunction
95 (3.3V~7.5V),85 (12V~48V)(TSW1:detectonheatsinkQ1ofpowertransistor)
105 (3.3V~7.5V),100 (12V~48V)(TSW2:d
etectonheatsinkHS4ofpowertransistor)
EMCIMMUNITY
EMCEMISSION

Summary of content (2 pages)