Datasheet

Universal AC input / Full range
Built-in active PFC function, PF>0.94
Protections: Short circuit / Overload / Over voltage / Over temperature
DC OK signal
5 years warranty
High efficiency up to 89%
Withstand 300VAC surge input for 5 seconds
Built-in constant current limiting circuit
Built-in cooling fan ON-OFF control
Built-in
Built-in remote sense function
All using 105 long life electrolytic capacitors
SPECIFICATION
HRP-600-3.3 HRP-600-5 HRP-600-7.5 HRP-600-12 HRP-600-15 HRP-600-24 HRP-600-36 HRP-600-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
OUTPUT VOLTAGE ADJ.RANGE
VOLTAGETOLERANCE Note.3
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
PROTECTION
ACCURRENT (Typ.)
3.3V 5V 7.5V 12V 15V 24V 36V 48V
120A
120A 80A 53A 43A 27A 17.5A 13A
0~120A 0~120A 0~80A 0~53A 0~43A 0~27A 0~17.5A 0~13A
396W 600W 600W 636W 645W 648W 630W 624W
100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
2.8~3.8V 4.3~5.8V 6.8~9V 10.2~13.8V 13.5~18V 21.6~28.8V 28.8~39.6V 40.8~55.2V
2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2%
1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5%
1000ms,50ms/230VAC2500ms,50ms/115VACatfullload
16ms/230VAC16ms/115VACatfullload
85~264VAC120~370VDC
47~63Hz
PF>0.94/230VACPF>0.99/115VACatfullload
78.5% 82%
6~7V 9.4~10.9V 14.4~16.8V 18.8~21.8V 30~34.8V 41.4~48.6V 57.6~67.2V
87% 88% 88% 88% 89% 89%
8.5A/115VAC5A/230VAC
35A/115VAC70A/230VAC
<1.2mA /240VAC
105~135%ratedoutputpower
3.96~4.62V
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2, heavyindustrylevel,criteria A
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
-40~+70 (Referto"DeratingCurve")
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G10min./1cycle,60min.eachalongX, Y,Zaxes
140.6Khrsmin.MIL-HDBK-217F(25 )
218*105*63.5mm(L*W*H)
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
HRP-600 se ri es
600WSingleOutputwithPFCFunction
1.5Kg;8pcs/13Kg/1.34CUFT
FileName:HRP-600-SPEC2011-08-09
80 5 (TSW1)detectonheatsinkofpowertransistor
90 5 (TSW2) for3.3V,5V,7.5V;100 5 (TSW2) power forothersdetectonheatsinkofpowerdoide detectonmain outputchoke
FUNCTION
DCOKSIGNAL
FANCONTROL (Typ.)
PSUturnon:3.3~5.6V;PSUturnoff:0~1V
Load35 15%orRTH2 50 Fanon
EMCIMMUNITY
EMCEMISSION

Summary of content (2 pages)