Datasheet

UL60950-1,EN60950-1,CCC GB4943,EAC TP TC 004 approved
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Built-in active PFC function
Low leakage current<1mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Low profile:31mm
Conformal coated
LED indicator for power on
Suitable for high efficiency moving sign applications
3 years warranty
2.5~3V
3.6~4.4V
VOLTAGE ADJ. RANGE
4.5~5.5V
105~150% rated output power
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
EMC EMISSION
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2000ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
180 ~ 264VAC 254 ~ 370VDC or 90~135VAC 127~190VDC
47 ~ 63Hz
2.8A/115VAC 1.4A/230VAC
Cold start 30A/115VAC 60A/230VAC
<1mA / 240VAC
3.22 ~ 3.78V
4.6 ~ 5.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32),GB9254,Class B, EN61000-3-2,-3,GB17625.1, EAC TP TC 020
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ )0.03%/ (0 ~ 60
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
263.2K hrs min. MIL-HDBK-217F (25 )
80%
PF 0.93/230VAC PF 0.98/115VAC at full load≥≥
8ms/230VAC 8ms/115VAC at full load
85%
±1.0%
±1.0%
±0.5%
±0.5%
±2.0%
±2.0%
110mVp-p
150mVp-p
2.8V
60A
4.2V
60A
HSP-300-2.8
HSP-300-4.2
File Name:HSP-300-SPEC 2018-01-09
Features :
HSP-300 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Please refer to Static Characteristics".
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.450 450 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.0KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
5.7 ~ 7.0V
87%
±1.0%
±0.5%
±2.0%
150mVp-p
5V
60A
HSP-300-5
300W Single Output with PFC Function
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV), criteria A, EAC TP TC 020
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
210*81*31mm (L*W*H)
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after fault condition is removed
4.7A/115VAC 2.35A/230VAC
0 ~ 60A
0 ~ 60A
CURRENT RANGE
Note.5
0 ~ 60A
168W
252W
RATED POWER
(convection)
300W
0.8kg; 15pcs/ 12.1kg/ 0.7CUFT
3.9A/115VAC 1.95A/230VAC
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
S
&
E