Data Sheet

Table Of Contents
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL LPC-60-1050 LPC-60-1400 LPC-60-1750
DC VOLTAGE RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER VOLTAGE
9 ~ 48V 9 ~ 42V 9 ~ 34V
50.4W 58.8W 59.5W
200mVp-p 200mVp-p 200mVp-p
±5.0%
±1.0%
±2.0%
500ms, 120ms / 230VAC 500ms, 120ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
87%
50.4 ~ 60V 44.1 ~ 56.7V
85%
39.1 ~ 45.9V
87%
1.2A/115VAC 0.7A/230VAC
COLD START 60A(twidth=540 s measured at 50% Ipeak) at 230VACμ
0.25mA / 240VAC
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A, EN61000-3-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
732Khrs min. MIL-HDBK-217F (25)
162.5*42.5*32mm (L*W*H)












. 
0.4Kg; 32pcs/13.8Kg/0.63CUFT
Protection type : Shut off o/p voltage, clamping by TVS diode
60W Single Output Switching Power Supply







 








LPC-60 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
50ms/230VAC 16ms/115VAC at full load
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH
File Name:LPC-60-SPEC 2020-03-05
RATED CURRENT 1050mA 1400mA 1750mA
±5.0%
CURRENT ACCURACY
EMC IMMUNITY
EMC EMISSION
UL1310, CAN/CSA C22.2 No. 223-M91(for LPC-60-1750 only), BIS IS15885(except for LPC-60-1750),
EAC TP TC 004, IP67, IEC/EN 62368-1 approved
IP67
LPS
 
IS 15885(Part 2/Sec13)
R-41027766
THOMAS SAMUEL
THOMAS SAMUEL

modify

Summary of content (2 pages)