Datasheet

SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT Note.6
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE Note.5
AC CURRENT (Typ.)
1000ms, 20ms/230VAC 1000ms, 20ms/115VAC at full load
100ms/230VAC 24ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 440Hz
76% 73% 78%
13.8 ~ 16.2V
79%
17.25 ~ 20.25V
81%
27.6 ~ 32.4V
0.35A/115VAC 0.2A/230VAC
COLD START 30A/115VAC 50A/230VAC
Above 105% rated output power
5.75 ~ 6.75V3.8 ~ 4.95V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
I/P-O/P:4KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
20 ~ 90% RH non-condensing
-20 ~ +70 (Refer to "Derating Curve")
-40 ~ +85, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
499.7Khrs min. MIL-HDBK-217F (25)
70*48*22mm (L*W*H)
0.065Kg; 120pcs/8.8Kg/0.97CUFT
File Name:NFM-15-SPEC 2017-07-14
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±1.0%
±1.0%
±1.0%
±1.0%
±2.0%
±2.0%
±1.0% ±1.0% ±1.0%
80mVp-p80mVp-p 150mVp-p 150mVp-p 240mVp-p
5V3.3V 12V 15V 24V
3A3.5A 1.25A 1A 0.63A
0 ~ 3A0 ~ 3.5A 0 ~ 1.25A 0 ~ 1A 0 ~ 0.63A
15W11.55W 15W 15W 15.12W
NFM-15-5 NFM-15-12 NFM-15-15 NFM-15-24NFM-15-3.3
SAFETY STANDARDS
15W Output Switching Power Supply
NFM-15 series

RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3







 
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
Tj 140 typically (U1) detect on main control IC
Protection type : Shut off o/p voltage, clamping by zener diode
10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V4.5 ~ 5.5V3 ~ 3.63V
Compliance to EN55011(CISPR11), EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A












ANSI/AAMI ES60601-1,TUV EN60601-1, IEC60601-1, UL60950-1 approved
EMC IMMUNITY
EMC EMISSION
Touch current < 80 A/264VAC
μ
ISOLATION LEVEL
Primary-Secondary: 2xMOPP