User manual

6
Figure 6 .3 8 stage charging curve
Charge
Current
stage 1 stage 2 stage 3 stage 4 stage 5 stage 6 stage 7 stage 8
Charge
Voltage
Pulse Soft
Start
Constant
Current
Cons ta nt
Volt age
Analysis Float Maintai n
Orange Green
Color of
LED
Explanation for 8 stag es charging curve
(0)Initial stage (battery analysis):
(1)Stage 1 (pulse charging) :
(2)Stage 2 (soft sta rt):
(3)Stage 3 (constant current):
(4)Stage 4 (constant voltage):
Check battery voltage level to se e if it is within the normal range, w hether o r not
a ba ttery is connected, or if the batte ry is already full and further charging is not
requ ired.
Pulse charging is used to revive tired lead acid battery which is either improperly
charged/discharged or allowed to self-discharge as occurs during non-use. Basically,
help to restore its norma l chemical pr operties.
Use low cha rge volt age and curr ent to prepare th e ba ttery to accept upcomin g
A high constant current is provided so the battery can be quickly charged to 2.4V
per cell.
A constant voltage of 2.4V per cell is provided until the charging current naturally
tapers down to a low level.
bulk charging, so a better charge can be applied.
St ar t
Bank A
Pulse
Charge
Bank B
Pulse
Charge
Bank A
Sof t
St art
Bank B
Sof t
St art
Bank A
Bank B
Bank A
Bank B
Constant
Constant
Constant
Constant
Current
Current
Voltage
Voltage
Bank A
Float
Charge
Bank B
Float
Charge
A/ B maintain charge cycl e
Bank A
Bank B
Analysis
Analysis
Bank A
Bank B
Mainta in
Mainta in
B ank A
B ank B
R econ-
dition
R econ-
dition
Re cond
Adva ntag e of floa t an d ma intain stage: Aft er LED t urns gre en, mainten ance
charge is provided so the battery is always in a full state. User will have access