Datasheet

AC input range selected by switch
Built-in passive PFC function compliance to EN61000-3-2
With AC ON-OFF switch
3 poles AC inlet with fuse holder
Protections:Short circuit/Over load/Over voltage/Over temperature
Charger type can be selected(Optional)
Charger for lead-acid batteries
2 color LED loading indicator
Open frame available
Low cost, High reliability
2 years warranty
Features :
S:Power Supply
A:Voltage detector
:O.D.M. number
P:Open P.C.B.
C:With case
13:13.8V
27:27.6V
54:55.2V
B:Current detector
P:With PFC
N:None PFC
P A 120 P 13 C
120W Single Output Power Supply or Battery Charger
PA/PB-120 series
SPECIFICATION
PA/PB-120 -13
PA/PB-120 -27 PA/PB-120 -54
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
LED INDICATED
OUTPUT
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
HARMONIC CURRENT
EMI CONDUCTION & RADIATION
SAFETY &
EMS IMMUNITY
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OVER LOAD
OVER VOLTAGE
PROTECTION
AC CURRENT
13.8V 27.6V 55.2V
7.2A 4.3A 2.2A
0 ~ 7.2A 0 ~ 4.3A 0 ~ 2.2A
99.36W
PA series voltage 105% 1% : RED / 105%
1% :GREEN
PB series load 46% 10% : GREEN / 46%
10% :RED
118.68W 121.44W
88 ~ 132VAC / 176 ~ 264VAC selected by switch
47 ~ 63Hz
>0.65 (with PFC series)
73% 79% 79%
3A/115VAC 1.5A/230VAC
COLD START 30A/115VAC 60A/230VAC
<1.5mA / 240VAC
90 ~ 110% rated output power
15 ~ 17V 30 ~ 35V 60 ~ 66V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
RTH2 70 10 Detect on RTH2 thermistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
UL1950, TUV E60950, EN60335, EN60335-1, EN60335-2-29 Approved
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
-10 ~ +45 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 45
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
R
TUV
Rheinland
ProductSafety
geprUfre
Sicherheit
MTBF
149.6K hrs min. MIL-HDBK-217F (25 )
DIMENSIONOTHERS
NOTE
PACKING
PCB Type:144*90*35mm External case type:180*96*49mm (L*W*H)
1.1Kg; 16pcs / 17.6Kg / 1.64CUFT(without PFC) 1.24Kg; 16pcs / 24.8Kg / 1.64CUFT(with PFC)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. With PFC I/P range: 95~132VAC/190~264VAC.
6. For open P.C.B. WITH 17.8CFM min. Forced air.
File Name:PA,PB-120-SPEC 2004-02-26

Summary of content (2 pages)