Datasheet

3 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protection: Short circuit / Overload / Over voltage / Over temperature
2 color LED loading indicator
Low cost, high reliability
2 years warranty
Built-in cooling Fan ON-OFF control
Built-in remote ON-OFF control
Features :
PB-230-12
MODEL
BOOSTCHARGEVOLTAGE
FLOATCHARGEVOLTAGE
OUTPUTCURRENT
BATTERY TYPE
RECOMMENDEDBATTERY
CAPACITY(AMP HOURS)(Note5)
OUTPUT
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
OVERLOAD
OVERVOLTAGE
PROTECTION
ACCURRENT (Typ.)
14.4V
13.6V
16A
Open&SealedLead Acid
50~160Ah
90~264VAC127~370VDC
47~63Hz
81.5%
3A/115VAC1.5A/230VAC
COLDSTART 50A
<3.5mA /240VAC
90~110%ratedoutputcurrent
16~18V
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype: Shutdowno/pvoltage,re-powerontorecover
Protectiontype: Automaticallyderatechargecurrentuntilzero
UL1012(forPB-230-xxAD1only), TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
-20~+50 (Referto"DeratingCurve")
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
MTBF
244.5Khrsmin.MIL-HDBK-217F(25 )
190*96*49mm(L*W*H)
DIMENSIONOTHERS
NOTE
PACKING
1.21Kg;12pcs/15.5Kg/1.29CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
FUNCTION
REMOTECONTROL (CN105)
FANCONTROL
TEMPERATURESENSE
Open:NormalworkShort:StopCharging
RTH3 50 FanON, 45 FanOFF(Typ.)
ByNTC
PB-230-24 PB-230-48
28.8V 57.6V
27.2V 54.4V
8A 4A
24~80Ah 12~40Ah
85.5% 86%
31~35V 59~64V
FileName:PB-230-SPEC2011-08-18
ORDERNO. OUTPUTCONNECTOR SAFETY
PB-230-xx(standardmodel) 4pinpowerdin TUV/CE
PB-230-xxAD1(optionalmodel)
PB-230-xx xx=12,24,48; =Blank, AD1
Andersonconnector UL
POWERFACTOR(Typ.) PF>0.95/230VACPF>0.98/115VACatfullload
TUV
Rhe inl and
Pro duc tSafe ty
geprUfre
Sicherheit
( for PB-230-xxAD1 only)
CONNECTOR
PLUG
CABLE
Seepage2 thertypeavailablebycustomerrequested;O
Seepage2 thertypeavailablebycustomerrequested;O
230WSingleOutputBatteryCharger
PB-230 series
SPECIFICATION
EMCIMMUNITY
EMCEMISSION