Data Sheet

Charger for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries
(lithium iron and lithium manganese) (Note.1)
3 stage charging
AC 115/230VAC selected by switch
Built-in passive PFC function compliance to EN61000-3-2 Class A (option)
Protection: Short circuit / Reverse polarity / Over voltage / Over temperature
2 color LED loading indicator
Low cost, High reliability
FAN on/off control(Depends on charging current)
3 years warranty
Features :
P:With Passive PFC
N:Without Passive PFC
PB 360 12
SPECIFICATION
PB-360 -12
MODEL
OUTPUT CURRENT (Typ.) Note 7
BATTERY TYPE
VOLTAGE ADJUSTABLE RANGE
RECOMMENDED BATTERY
CAPACITY(AMP HOURS)
Note 6
OUTPUT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note 5)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OVER VOLTAGE
REVERSE POLARITY
PROTECTION
AC CURRENT (Typ.)
14.4V
13.6V
24.3A
Open & Sealed Lead Acid
80 ~ 240Ah
13 ~ 14.7V
90 ~ 132VAC / 180 ~ 264VAC selected by switch 127 ~ 187VDC / 254 ~ 370VDC
47 ~ 63Hz
85%
7A/115VAC 3.5A/230VAC
COLD START 60A
<3.5mA / 240VAC
16 ~ 18V
By internal fuse
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Automatically derate charge current until zero
IEC60335-2-29 CB approved by TUV(except for 48V), UL62368-1, CSA C22.2 , EAC TP TC 004 approvedNo. 62368-1
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3 (only P type), EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃ 0.05%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
MTBF
115.8Khrs min. MIL-HDBK-217F (25 )
253*135*48.5mm(L*W*H)
DIMENSIONOTHERS
NOTE
PACKING
1.5Kg; 6pcs/10Kg/0.95CUFT
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
7. Maximum charging current will be in the range of 90~110% rated output current.
8. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
P
PB-360 series
360W Single Output Battery Charger
FUNCTION
REMOTE CONTROL (CN5)
Open: Normal work Short: Stop Charging
12:14.4V
24:28.8V
48:57.6V
PB-360 -24 PB-360 -48
28.8V 57.6V
27.2V 54.4V
26 ~ 28.8V 52 ~ 58.6V
12.5A 6.25A
40 ~ 125Ah 20 ~ 65Ah
86% 87%
31 ~ 35V 59 ~ 64V
SHORT CIRCUIT
O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on
File Name:PB-360-SPEC 2020-04-14
POWER FACTOR (Typ.) >0.65 (with P type) at 230VAC
EMC IMMUNITY
EMC EMISSION
BOOST CHARGE VOLTAGE Vboost
FLOAT CHARGE VOLTAGE Vfloat
(P type only)
TPTC004
(except for 48V)
IEC62368-1UL62368-1

Summary of content (2 pages)